TUNER SECTION
0 dB = 1 µV
• FM Section
Setting:
BAND button: FM
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz signal
output level : as low as possible
• AM Section
Setting:
BAND button: AM
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
• Connecting Level Meter (FM and AM)
set
SPEAKER, L-CH (SP301)
• Connecting Digital Voltmeter (FM and AM)
100 kΩ
TP (VT)
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
TP (FM IN)
0.01 µ F
set
Put the lead-wire
antenna close to
the set.
level meter
(range: 0.5–5 V ac)
4 Ω
digital
voltmeter
FM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
10.7 MHz
FM FREQUENCY COVERAGE
ADJUSTMENT
Frequency Display
Reading on Digital voltmeter
Adjustment Part
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L1
87.5 MHz
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter.
450 kHz
AM FREQUENCY COVERAGE
ADJUSTMENT
(US, CND)
Frequency Display
(Except US, CND) (Except US, CND)
Reading on
1.0 ± 0.05 V
Digital voltmeter
Adjustment Part
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter.
L3
620 kHz (US, CND)
621 kHz (Except US, CND)
Adjustment Location: See page 18.
CSD-MP100
T2
87.5 MHz
108 MHz
1.3 ± 0.3 V
3.0 ± 0.2 V
<confirmation>
L2
CT1
108 MHz
T1
530 kHz
1,710 kHz
(US, CND)
531 kHz
1,611 kHz
5.3 ± 0.7 V
L4
<confirmation>
CT3
1,400 kHz (US, CND)
1,404 kHz (Except US, CND)
17