3. In the main menu, enter the machine-type model (MTM) number for the
4. Enter the serial number for the replacement switch. For example:
5. Reset the switch using the following command:
6. When prompted to confirm the reset, enter y. The switch reboots.
7. After the switch reboots, at the command prompt, verify that the VPD
44
IBM System Networking RackSwitch G8052: Installation Guide
replacement switch. For example:
/boot/mtm 1455-48E
where 1455-48E is the MTM of the unit that is being replaced
/boot/esn 1000001
where 1000001 is the serial number of the unit that is being replaced.
/boot/reset
information is correct by issuing the show sys-info command using the ISCLI
interface or the /info/sys/general command using MenuCLI interface.
ISCLI interface output example:
show sys-info
System Information at 13:41:04 Fri Jan 20, 2011
Time zone: America/US/Pacific
Daylight Savings Time Status: Disabled
IBM System Networking RackSwitch G8052
Switch has been up for 0 days, 17 hours, 10 minutes and 45 seconds.
Last boot: 20:41:01 Thu Jan 19, 2011 (power cycle)
MAC address: fc:cf:62:9d:2b:00 IP (If 1) address: 0.0.0.0
Management Port MAC Address: fc:cf:62:9d:2b:fe
Management Port IP Address (if 128): 203.203.21.2
Hardware Revision: 0
Hardware Part No: BAC-000*a*00
Switch Serial No: US7C45t78
Manufacturing date:
Software Version 6.6.0 (FLASH image1), active configuration.
Temperature Mother Top: 34 C
Temperature Mother Bottom: 38 C
Temperature Daughter Top: 35 C
Temperature Daughter Bottom: 37 C
Warning at 70 C and Recover at 100 C
Fan 1 in Module 1: RPM=17647 PWM=255(100%) Front-To-Back
Fan 2 in Module 1: RPM= 9310 PWM=255(100%) Front-To-Back
Fan 3 in Module 2: RPM=17419 PWM=255(100%) Front-To-Back
Fan 4 in Module 2: RPM= 9326 PWM=255(100%) Front-To-Back
Fan 5 in Module 3: RPM=17197 PWM=255(100%) Front-To-Back
Fan 6 in Module 3: RPM= 9523 PWM=255(100%) Front-To-Back
Fan 7 in Module 4: RPM=17252 PWM=255(100%) Front-To-Back
Fan 8 in Module 4: RPM= 9490 PWM=255(100%) Front-To-Back
System Fan Airflow: Front-To-Back
Power Supply 1: Vin Fault
Power Supply 2: OK
Or
MenuCLI interface output example:
/info/sys/general