Synco™ living
Operating Instructions
Edition 3.0
Controller series C
CE1B2707en
Building Technologies
23.08.2008

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Synco living

  • Page 1 Synco™ living Operating Instructions Edition 3.0 Controller series C CE1B2707en Building Technologies 23.08.2008...
  • Page 3 Congratulations … … on choosing the Siemens Synco™ living system and thank you for pur- chasing the central apartment unit! These operating instructions describe how to operate the central apartment unit and other system components. Symbols used The symbols on the central apartment unit’s are explained in section “Symbols on the display”...
  • Page 4: Table Of Contents

    Setting values and predefined settings ........25 Access levels..................26 User level ..................26 Service level................. 26 Expert level .................. 26 Settings..................... 26 General ..................... 27 Absence ..................... 27 4 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Contents 23.08.2008...
  • Page 5 Stage selection................... 45 Forced ventilation................45 State....................46 Reason....................46 Operating mode for absence.............. 46 Stage assignment to operating modes ..........47 Stage assignment to window states........... 47 5 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Contents 23.08.2008...
  • Page 6 Time switch for switching groups ............61 Time switch release................62 Time switch for simulation of presence ..........62 Activating simulation of presence............63 Release..................63 Function ..................64 6 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Contents 23.08.2008...
  • Page 7 Room operating modes..............80 Room timer function ................81 Readjustment of the room temperature setpoint........ 82 Display...................... 82 Full display ..................82 Possible displays................83 Error messages.................. 84 7 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Contents 23.08.2008...
  • Page 8 ........90 Function button on heating circuit controllers RRV912 / RRV918 and on multi-controller RRV934 ............91 Maintenance and cleaning................ 91 Disposal ......................91 Index....................... 92 8 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Contents 23.08.2008...
  • Page 9: Safety Notes

    • Application-related technical data are only guaranteed in connec- tion with the Siemens Synco™ living system. When using together with third-party products not specified by Siemens, user must en- sure functionality. In that case, Siemens does not provide any ser- vices or warranty. 9 / 100 Siemens Synco™...
  • Page 10: System Overview

    The rooms are grouped into one apartment. The operating modes and a holiday/special day program can be set for the apartment. The apartment operating mode allows for overriding the individual room operating modes. 10 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies System overview 23.08.2008...
  • Page 11: Room Temperature Setpoints

    (via radio signal) and forward the resulting positioning signals to the wire-bound actuators. They also facilitate the direct connection of an apart- ment pump and of DHW heating. 11 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies System overview...
  • Page 12: Cooling Release

    With central cooling (entire apartment) via a common 2-pipe heating/cooling system, cooling is accomplished using the same components as heating control. 12 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies System overview...
  • Page 13: Ventilation Control

    The central apartment unit can also be used for triggering manual forced charging of the DHW storage tank. The current DHW temperature appears on the display of the central apartment unit. 13 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies System overview 23.08.2008...
  • Page 14: Weather Station

    In addition to manual blind settings, the settings can also be made via the built-in time switch or events. The light settings and blind positions can be jointly stored as a scene or jointly readjusted when calling up a scene. 14 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies System overview...
  • Page 15: Operation Of Lights And Blinds

    The lights and blinds can be controlled with the central apartment unit’s soft- keys. Prerequisite for this operation is that the light and blind actuators used have a binding facility for KNX-RF (KRF960, KRF961, Siemens GAMMA wave or Hager tebis TX radio) or KNX TP1. Supervisory functions The central apartment unit monitors the connected window contacts, door contacts and smoke detectors.
  • Page 16: System Components

    HR bypass, or controls 2 independ- ent room groups. Universal inputs and outputs. SSA955 Radiator control actuator ERF910 RF repeater (retransmitter) KRF960 Radio plug adapter, switching KRF961 Radio plug adapter, dimming 16 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies System overview 23.08.2008...
  • Page 17 The central apartment unit can also control light and blind actuators via KNX TP1 (S-Mode). In that case, configuration with the ETS (EIB tool software) is required. 17 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies System overview...
  • Page 18: Central Apartment Unit Qax910

    / Economy / Protection). The apartment mode applies to room control and ventilation. Info button For scrolling through the info pages, and for calling up Help text on the menu level. 18 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 19 1A, 1B Softkeys 1A and 1B 2A, 2B Softkeys 2A and 2B 3A, 3B Softkeys 3A and 3B 4A, 4B Softkeys 4A and 4B 19 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 20: Display

    DHW… Scroll bar: Shows the position on the menu list Cursor position: Appears as a black bar with inverse text Extension: Further entries follow 20 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 21: Navigating On The Display / Information About Paths

    Flashing: Manual forced charging of DHW active DHW heating enabled Other operating states Fault Absent Flashing: Fault, acknowl- Present edgement required Holiday mode Special day 21 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 22 Time of day / date Rooms Faults Room groups Inputs / outputs Ventilation Settings Device information Switching groups Data backup Supervision Commissioning Access levels Service level Expert level 22 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 23: Operation

    The type and number of available info pages depend on your plant (number of rooms, switching groups, etc.). The info pages can also be called up via appropriately assigned soft- keys (refer to page 59). 23 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 24: Menu Level

    The selection made is Auto identified by a tick ” “. Only one Comfort element of the list can be activated at Precomfort a time. 24 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 25: Selecting Options

    Setting recommended for most types of plant. Factory setting Setting that should be adapted depending on user- or plant-specific requirements. Use the predefined fields for entering your own settings. 25 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 26: Access Levels

    If, with a selected parameter, the Info button is pressed, the path and full text of the respective parameter will appear. 26 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 27: General

    See "Release of supervision“ page 66. When supervised windows and doors are open and when supervision is acti- vated, an associated display appears and a constant signal is sounded. 27 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 28: Apartment

    When pressing the Mode button, an additional window appears (Mode pop- up). Now, you can select the required apartment operating mode (heating, cooling, ventilation) with the Arrow buttons or the Mode button. 28 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 29: Operating Mode Via Contact

    Main menu > Apartment > Apartment operating mode > Optg mode contact: Factory setting Protection Your setting --- (no influence) Comfort Precomfort Economy Protection 29 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 30: Summer Operation Of Heating

    01.01. (inactive) Your setting If the date settings for the beginning and the end of summer coincide, there is no date-dependent changeover to summer operation. 30 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 31: Antilime Function

    Cooling mode is locked below the set temperature. Main menu > Apartment > Settings > OT cooling limit: Factory setting --- (Inactive – no heating limit) Setting ………………°C 31 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 32: Rooms 1 - 12

    • Room operating mode / apartment operating mode / operating mode contact • Room timer / apartment timer • Summer • Optimum start control / optimum stop control • Open window 32 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 33: Plant Operating Mode

    If the room temperature is at least 0.5 °C above the average value, cooling mode is released Heating mode Cooling mode H Cw Heating Comfort setpoint K Cw Cooling Comfort setpoint Room temperature 33 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 34: Room Operating Mode During Absence

    Main menu > Rooms > Room X > Room operating mode > Optg mode absence: Room number Room name Factory setting Setting 34 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 35: Release Of Air Conditioner

    > Rel air conditn from: Room number Room name Factory setting Setting Room number Room name Factory setting Setting = Comfort = Precomfort = Economy = Protection 35 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 36: Room Temperature Setpoints

    / items such as plants, pictures, etc. Excessively high room temperatures can cause irreparable damage! Low room temperature setpoints result in higher cooling costs. 36 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 37: Readjustment Of Room Unit

    Comf points. The factory settings of the switching times of all weekdays are 06:00 (changeover to Comfort mode) and 22:00 (changeover to Economy mode). 37 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 38 Arrow buttons 06:00 Comf From 06:00 and then press the Menu / ok button. Use the Arrow buttons to change the value. 38 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 39: Actual Value Of The Room Temperature

    The current plant state (Auto / Heating / Cooling) can be queried for each room: Main menu > Rooms > Room X > Room state > Plant operation: 39 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 40: Economy Increase

    (e.g. at the end of the holiday period). If that is not the case (too early or too late), a new changeover time is calcu- lated, which is used on the next day. 40 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 41: Room Temperature Supervision

    Main menu > Rooms > Room X > Room settings > Min temp alarm: Room number Room name Factory setting ---- ---- ---- ---- ---- ---- Max temp. alarm Min temp. alarm 41 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 42: Window Airing Function

    Room name Factory setting 00.30 00.30 00.30 00.30 00.30 00.30 Setting Room number Room name Factory setting 00.30 00.30 00.30 00.30 00.30 00.30 Setting 42 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 43: Silent Mode

    Main menu > Rooms > Room X > Room settings > Sensor readjustment: Room number Room name Factory setting Readjustment Room number Room name Factory setting Readjustment 43 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 44: Room Group

    Shows the current operating state (Off / On) of the corresponding room group pump. Main menu > Room groups > Room group X > State > Room group pump: 44 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 45: Room Valve Position Max

    Forced ventilation can also be triggered by pressing the ventilation button on the central apartment unit a bit longer. Main menu > Ventilation > Operating mode > Forced ventilation: 45 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 46: State

    The setting for the ventilation mode for absence does not depend on the setting for room operating mode for absence. However, both operating modes can be changed over via the absence button. 46 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 47: Stage Assignment To Operating Modes

    (see page 54). Main menu > Ventilation > Stage setpoints > Window open: Factory setting Setting Stage 1 Stage 2 Stage 3 47 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 48: Stage Assignment For Smoke

    The setting is carried out based on the room time switch (see page 37). The factory setting contains the switching times for all weekdays at 06:00 (changeover to Comfort) and 22:00 (changeover to Economy). 48 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 49: Ventilation Stage

    Main menu > Ventilation > Ventilation state > IAQ: Air humidity Shows the relative air humidity (0..100%) on the sensing element. Main menu > Ventilation > Ventilation state > Air humidity: 49 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 50: Open Fireplace Mode

    The operating hours must be reset to 0 to delete the service message. The operating hours since service can be set to 0 or any value. Main menu > Ventilation > Service > O’hrs since service: 50 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 51: Indoor Air Quality Setpoints

    The current relative room humidity (% r.h.) is displayed on the central apart- ment unit. 51 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 52: Stage Setpoint For Humidity Limitation

    / special day) must be shorter than the set max precooling time. Night cooling ends if one of the release criteria is not met or when the Comfort heating setpoint is reached. 52 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 53: Stage Setpoint For Night Cooling

    Ventilation in holiday mode runs every day for the period set here (00.00..06.00 hh.mm). Main menu > Ventilation > Ventilation settings > Holiday mode period: Factory setting 00.30 hh.mm. Setting 53 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 54: Runtime Forced Ventilation

    The DHW temperature is maintained at the frost Protection setpoint. The selection can also be made via the menu: Main menu > DHW > Operating mode > Preselection: 54 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 55: Forced Dhw Charging

    Main menu > DHW > Operating mode > Optg mode absence: Factory setting Your setting --- (no impact, according to time program) Normal Reduced Protection 55 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 56: Operating Mode Via Contact

    The central apartment unit is supplied with the following factory set- tings for all weekdays: 05:00 for changeover to the Normal setpoint, 22:00 for changeover to the Reduced setpoint. 56 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 57: Actual Value Of The Dhw Temperature

    The maximum permissible charging time was preset when the plant was commissioned. Main menu > DHW > DHW state > Charging time limit: 57 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 58: Changeover To Electric Immersion Heater

    Main menu > DHW > Settings > Min temp alarm: Max temp alarm Min temp alarm Factory setting ---- (inactive) ---- (inactive) Your setting 58 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 59: Switching Groups

    The switching groups can also be triggered via the operating lines. You operate a switching group configured for Switch, Dim or Blind under: Main menu > Switching groups > Switching group X > Trigger: 59 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 60: Scenes

    Switch or Dim: Main menu > Switching groups > Switching group X > Events on cmd: Main menu > Switching groups > Switching group X > Events off cmd: 60 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 61: Time Switch For Switching Groups

    The time switch settings are made analogously to those of the room time switch (refer to page 37). Main menu > Switching groups > Switching group X > Time switch > 61 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 62: Time Switch Release

    Using the special day, define whether and for what periods of time during holidays and special days you want presence simulation. The periods of time defined apply jointly to all switching groups. 62 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 63: Activating Simulation Of Presence

    Example of release according to the time switch: B2707Z01 Time program presence simulation (On, Off) Absence (On, Off) Release of simulation (On, Off) Time 63 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 64: Function

    Contin on Switching group 5 Factory setting Random Random Random Random Your setting Random Random Random Random Contin on Contin on Contin on Contin on 64 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 65: Supervision

    Your setting You can set the volume of the signal / beep as desired (0..100%). While you adjust the volume, a constant beep is sounded at the selected volume. 65 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 66: Release Of Supervision

    Room 7 Room 7 Room 8 Room 8 Room 9 Room 9 Room 10 Room 10 Room 11 Room 11 Room 12 Room 12 66 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 67: Doors

    Main menu > Supervision > Doors > Volume mess delay Factory setting Your setting If event "Window / door supervision" is active at the buzzer (see parameter below), the actual alarm is sounded 67 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 68: Event Buzzer And Status Output

    In that case, you can also define whether the event is repeated every year (* with entry of year), or whether it should be deleted again after the event took place (entry with indication of year). 68 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 69: Holidays And Absence Simultaneously

    Comfort setpoint is quickly reached again. Slow heating systems (e.g. underfloor heating systems) require more time until the desired room temperature is reached. 69 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 70: Apartment Operating Mode During Holidays

    Main menu > Time of day/date > Time of day: Main menu > Time of day/date > Date: Main menu > Time of day/date > Year: 70 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 71: Faults

    A fault that has not yet been acknowledged appears on the display with a flashing fault symbol. As soon as the fault is acknowledged, the fault symbol will stop flashing. 71 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 72: Inputs / Outputs

    • Heat demand relay • Heat demand DC 0..10 V • Summer operation • Status output • Window / door state • Exhaust hood 72 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 73: Settings

    Main menu > Settings > Device > Backlit display: Main menu > Settings > Device > Display contrast: Backlit display Display contrast Factory setting 100% Your setting 73 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 74: Display Format

    Select the room (rooms 1 – 12) whose temperature should be displayed in the quiescent picture. Main menu > Settings > Quiescent picture > Temp display: Factory setting Room 1 Your setting 74 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 75: Password For The Service Level

    Softkeys of switching group 1 2A, 2B Softkeys of switching group 2 3A, 3B Softkeys of switching group 3 4A, 4B Softkeys of switching group 4 75 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910 23.08.2008...
  • Page 76: Fault Inputs 1 - 8

    • Normal position: It can be selected here whether an open or closed contact should be used to indicate a faulty condition. Normally open means that an open contact is considered to indicate ”nor- mal operation” 76 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 77: Fault Outputs 1 And 2

    (CE1C2707en)“. Main menu > Settings > Faults > Fault output X > Fault priority: Main menu > Settings > Faults > Fault output X > Fault source: 77 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 78: Plant Name

    Assign the switching groups self-explanatory names, e.g. Living, Eating, Par- ents, Children, Bathroom, etc. Main menu > Settings > Text > Switching groups > Switching group X: 78 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 79: Door Names 1 - 2

    Main menu > Device information > File name: Main menu > Device information > Device type: Main menu > Device information > Software version: Main menu > Device information > Hardware version: 79 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Central apartment unit QAX910...
  • Page 80: Room Unit Qaw910

    The room is maintained at the Protection setpoint. Overriding by the central apartment unit to maintain the Comfort setpoint. Overriding by the central apartment unit to maintain the Precomfort setpoint. 80 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Room unit QAW910 23.08.2008...
  • Page 81: Room Timer Function

    For the room timer function to be activated, the apartment operating mode must be set to ”Auto”. In addition, no absence or holiday function for the apartment may be active. 81 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Room unit QAW910 23.08.2008...
  • Page 82: Readjustment Of The Room Temperature Setpoint

    Comfort or the Precomfort setpoint. Display Full display When commissioning the unit, the full display appears for 2 seconds, ena- bling you to check it. 82 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Room unit QAW910 23.08.2008...
  • Page 83: Possible Displays

    / querying the current / resulting room operating mode. °C Unit of room temperature Readjustment bar indicates an active room temperature setpoint readjustment. 83 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Room unit QAW910 23.08.2008...
  • Page 84: Error Messages

    In the event of communication errors, check the central apartment unit’s power supply. If power supply is in order, a radio repeater might be required. 84 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Room unit QAW910...
  • Page 85: Radio Plug Adapter

    LED off (output off) • LED off (output off) and press button LED lit (output 100%) The local button does not allow for dimming the output. 85 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Radio plug adapter 23.08.2008...
  • Page 86: Service

    If, during the binding test, the green LED of the respective device is lit, battery capacity is sufficient. If, during the binding test, the red LED of the respective device is lit or is dark, battery capacity is insufficient. 86 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Service...
  • Page 87: Replace Batteries

    Remove the exhausted batteries. Insert the new batteries. Ensure that polarity is correct! Replace the battery compartment Dispose of the old batteries in compli- cover. ance with environmental regulations. 2701Z22 87 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Service 23.08.2008...
  • Page 88: Display After Battery Change

    Press on the snap-on cover… ready for insertion (LR6 / 1.5 V). 2707Z22 2707Z23 … and remove the battery compart- Remove the old batteries. ment cover. 2707Z26 2707Z25 88 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Service 23.08.2008...
  • Page 89: Door / Window Contact Wave Ap 260 And Delta Reflex Smoke Detector

    For changing the batteries of the door / window contacts and the DELTA reflex smoke detectors, please refer to the Operating and Mounting Instructions supplied with these devices. 89 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Service...
  • Page 90: Binding Tests

    Room unit QAW910 Radiator control actuator SSA955 Room sensor QAA910, meteo sensor QAC910, and radio repeater ERF910 = function button LED = light emitting diode 90 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Service 23.08.2008...
  • Page 91: Function Button On Heating Circuit Controllers Rrv912 / Rrv918 And On Multi-Controller Rrv934

    Comply with local and currently valid legislation. Dispose of discharged batteries in compliance with relevant environmental regu- lations. 91 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Disposal...
  • Page 92: Index

    DHW operating mode ....54 absence ........55 DHW operating mode... 55 DHW plant operation .... 57 cause ........55 holidays ........70 operating mode ventilation ... 46 92 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Index 23.08.2008...
  • Page 93 ......50 flow temperature KRF960 ......16, 85 actual value room group ..44 KRF961 ......16, 85 room group......44 setpoint room group ..... 44 93 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Index 23.08.2008...
  • Page 94 ..56 optimum group pump ......44 start control......40 name 1 - 12 ......78 stop control......40 operating mode ..32, 34, 80 outputs ........72 timer function ......81 94 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Index 23.08.2008...
  • Page 95 70 humidity limitation....52 of day format ......73 night cooling ......53 time switch ....... 61 state DHW ........56 air conditioner....... 39 release........62 95 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Index 23.08.2008...
  • Page 96 .47 contacts ........ 50 winter operation ......30 control........13 wireless smoke detector ...15 impact window switches ..54 service ........50 settings ......... 45 year...........70 96 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies Index 23.08.2008...
  • Page 97 97 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies 23.08.2008...
  • Page 98 98 / 100 Siemens Synco™ living Operating instructions CE1B2707en Building Technologies 23.08.2008...
  • Page 100 Siemens Switzerland Ltd. © 2006-2008 Siemens Switzerland Ltd Building Technologies Group Subject to change International Headquarters 0678 Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 Fax +41 41-724 35 22 www.siemens.com/sbt 7 4 3 1 9 0 5 4 2 0...

Table of Contents