    Contents Application ....................3 Safety precautions................... 4 Scope of delivery ..................6 Installation and assembly ............... 7 Connections and startup................. 8 Connecting the power and signal cables............8 5.1.1 Position of connections..................8 5.1.2 Power supply connection.................. 9 5.1.3 DVI connection ....................9 5.1.4 Connection procedure ..................
  • Page 3 Contents 10.03 Dimensional drawings................23 10.1 Front view ....................... 23 10.2 View from left ....................24 10.3 Plan view ......................25 Remarks and contact address .............. 26 11.1 Remarks ......................26 11.2 Contact address....................26 21" gray scale flat panel display SMD 21300 A5E00185696B-001...
  • Page 4: Application

    10.03 Instruction Manual Application The gray scale flat panel display SMD 21300 CS Order No.: 6GF6201-5WA01 SMD 21300 D Order No.: 6GF6201-5WA03 has been specially designed for medical diagnostics. The display is available for ceiling suspension (CS) and as a desktop version (D). The two displays differ in that the desktop version is supplied together with a stand and cable.
  • Page 5: Safety Precautions

    10.03 Instruction Manual Safety precautions Correct and safe operation of the display is dependent on proper transport, storage, installation and assembly, as well as careful operation and maintenance. The unit must only be used for applications normally requiring a display. The information in the Section "Technical data"...
  • Page 6 10.03 Instruction Manual Caution Incorrect installation may result in extensive damage to property. Installation must be carried out by specialists: 1. When installing your medical electrical system with our products in an environment with patients, please observe the safety requirements of IEC 60 601-1 and its corresponding national translation for "Specifications for the safety of medical electrical systems"...
  • Page 7: Scope Of Delivery

    10.03 Instruction Manual Scope of delivery SMD 21300 CS: • Display without stand • CD with Instruction Manual and VOSD SMD 21300 D: • Display with stand • CD with Instruction Manual and VOSD • European power cable • US power cable •...
  • Page 8: Installation And Assembly

    10.03 Instruction Manual Installation and assembly Distances The unit should be positioned on a hard, level and horizontal surface. It should be positioned at least 10 cm at the side and rear from a wall or 15 cm from other units.
  • Page 9: Connections And Startup

    10.03 Instruction Manual Connections and startup Caution In order to ensure safe operation of the equipment, close attention must be paid to the information contained in this Instruction Manual as well as the warnings in Section 2 "Safety precautions". Note All screening precautions contained in the corresponding EMC guidelines must be observed.
  • Page 10: Power Supply Connection

    10.03 Instruction Manual 5.1.2 Power supply connection Check the permissible voltage range before connecting the display (see Section 9.2). Caution Only use the power cable supplied in the delivery, or a cable with PE conductor and appliance socket to DIN 49 547, IEC 320 (max. length 3 m, cable e.g. H05VV-F 3x1.0 mm ).
  • Page 11: Serial Interface

    10.03 Instruction Manual Serial interface The display has a serial RS 232 interface with 6-contact mini-DIN socket. The following units may be connected to the socket: − Ambient lighter sensor for the SMD display range (permissible in patient environment) − Serial luminance meter with adapter from 9-contact Sub-D to 6-contact mini- DIN socket *) −...
  • Page 12: Screen Saver

    10.03 Instruction Manual Screen saver • A screen saver function should be used in order to reduce "image sticking" which can occur in TFT displays. Image sticking is the effect where a faint image of the previous screen contents can still be seen after the display contents have changed.
  • Page 13: Adjustments

    10.03 Instruction Manual Adjustments Overview All displays are optimally set in the factory so that no adjustments are usually necessary. If adjustments to the settings are nevertheless required, they can be made using the VOSD and SMfit ACT (V3.0 or later) program. The VOSD program is supplied for each display as a Windows version on CD.
  • Page 14: Vosd Program Description

    10.03 Instruction Manual VOSD program description Main menu Function Adjustment/range Description System (U) ISP enable (S) Button "Yes", "No" Enabling of display for single download (ISP = In System Programming) 8/10-bit video signal (S) Mode - 8-bit video input signal Adaptation to video output of graphics card.
  • Page 15: Instruction Manual

    10.03 Instruction Manual Main menu Function Adjustment/range Description Configuration Backlight (S) Backlight control On/off Activation/deactivation of backlight control Saved backlight 0-1023 (read only) Last saved reference value of backlight control reference value Actual backlight 0-1023 Current reference value of backlight control reference value Backlight sensor 0-1023 (read only)
  • Page 16: Short Cuts

    10.03 Instruction Manual Main menu Function Adjustment/range Description Test pattern DIN geometry (U) Display test pattern DIN gray (U) Display test pattern DIN resolution (U) Display test pattern SMPTE (U) Display test pattern Grid (U) Display test pattern Briggs (U) Display test pattern Astigmatism (U) Display test pattern...
  • Page 17: Operation

    10.03 Instruction Manual Operation Switching on the display and PC • Switch on all displays and the PC (note: any switch-on sequence) • The operation LED now lights up green permanently. Cleaning Caution Care of unit / cleaning agents • The front panel is extremely sensitive to mechanical damage. Avoid all scratches, knocks etc.! •...
  • Page 18: Maintenance

    10.03 Instruction Manual Maintenance The displays require little maintenance. Only the illumination properties slowly change due to aging of the LCD unit and the backlight. Therefore the display settings must be checked at regular intervals by servicing personnel according to the regulations, and corrected as necessary.
  • Page 19: Fault Diagnostics

    10.03 Instruction Manual Fault diagnostics The LED continuously lights up green in normal mode. In the event of a malfunction, the fault can be located using the screen display and the control LED. Screen Cause Remedy Switch off Switch on the power switch Power cable not Check power supply cable inserted or incorrectly...
  • Page 20: Technical Data

    10.03 Instruction Manual Technical data All technical data are valid after a warming-up period of 2 hours. Display Type TFT, dual domain, IPS mode, amorphous Si Picture size 318 mm x 424 mm Picture diagonal 20.8" (52.8 cm) Resolution Max. 1536 x 2048 (full-screen format) Pixel organization 3 subpixels per pixel Pixel spacing...
  • Page 21: Inputs/Outputs

    10.03 Instruction Manual Inputs/outputs DVI input DVI-I socket (analog pins are not used) Single link 1536 x 2048 at 60 Hz The SMG 2125 D and SDG 2125 DM graphics cards are recommended as the interface module. In the DVI cable RS 232 Via mini-DIN service socket Controls and connection elements...
  • Page 22: Climatic Conditions

    10.03 Instruction Manual Climatic conditions Operation Ambient temperature range 0 °C to 35 °C Temperature gradient Max. 5 °C/h, no condensation Atmospheric pressure 1040 to 860 hPa Transport and storage (packed) Ambient temperature range -20 °C to +60 °C Temperature gradient Max.
  • Page 23: Electromagnetic Compatibility

    10.03 Instruction Manual Electromagnetic compatibility EMI voltage/ EN 60 601-1-2 Class B radiated interference EN 55 011 Voltage variations EN 61 0004-11 Burst on power supply lines EN 61 000-4-4 2 kV Burst on signal line EN 61 000-4-4 1 kV Surge on power supply lines EN 61 000-4-5 1 kV symmetric,...
  • Page 24: 10 Dimensional Drawings

    10.03 Instruction Manual 10 Dimensional drawings All dimensions in mm. 10.1 Front view 21" gray scale flat panel display SMD 21300 A5E00185696B-001...
  • Page 25: View From Left

    10.03 Instruction Manual 10.2 View from left 21" gray scale flat panel display SMD 21300 A5E00185696B-001...
  • Page 26: Plan View

    10.03 Instruction Manual 10.3 Plan view 21" gray scale flat panel display SMD 21300 A5E00185696B-001...
  • Page 27: 11 Remarks And Contact Address

    Guarantee All commitments on the part of Siemens AG are contained in the respective sales contract which also contains the complete and solely applicable warranty conditions. These warranty conditions in the contract are neither extended nor limited by the contents of this Instruction Manual.