CP 523
6.3
Setting the CP 523 Parameters in Print Mode
The CP 523 can only be operated in Print mode if an initialized memory submodule has been
plugged in. Store the following in the memory submodule:
•
Parameter setting data for the CP 523 in data block (DB) 1
•
Message texts in DB 2 to 255 ( 6.4)
The CP 523 has default values for all parameters.
•
Parameters for the printer interface (baud rate, type of interface, BUSY signal, ...)
•
Configuration data for entering message texts (function character, end-of-text character)
•
Configuration data for the message text printout (output format for date and time of day,
headers and footers, ...)
If you want to configure the CP 523 with other data, you must store the configuring data on a
memory submodule in DB 1. This data is subdivided into ten parameter blocks to simplify entry as
much as possible.
Parameter
Block Number
Setting the serial interface parameters:
0
Serial interface parameters
1
Waiting times after "CR", "LF" and "FF"
(only relevant if BUSY signal "0" and no XON/XOFF protocol has been
configured)
2
XON/XOFF protocol (only relevant if XON/XOFF protocol is in use)
The XON/XOFF protocol has priority over the BUSY signal
Configuring data for entering message texts:
3
Text parameters
Configuring data for message text printout:
4
Output format for date and time of day
5
Page format
6
Headers and footers (only relevant if headers and footers are to be printed)
Setting the mode:
7
Parameters for Communications mode
8
Character conversion table
9
Correction value for the integral clock
EWA 4NEB 811 6044-02a
Table 6-1. Contents of the Parameter Blocks
Contents
Print Mode
6-3