Zones; System Alerts; Expanders; Keypads - Siemens SPC4000 Installation & Configuration Manual

Intrusion
Hide thumbs Also See for SPC4000:
Table of Contents

Advertisement

User Menus Via the Keypad

12.15.1 Zones

12.15.2 System Alerts

12.15.3 Expanders

12.15.4 Keypads

100
Siemens Building Technologies
Fire Safety & Security Products
The zone status page displays each of the zones on the system with the following
information:
Zone Name: a 16 character name that identifies the Zone
Area: the area to which the zone is mapped
Zone Type: the type of zone
Input: the condition of the input (open/closed, etc.)
Status: the status of the input (OK, Tamper, etc.)
Action: if the user has the rights to inhibit or isolate a zone, these options are
presented for that zone; to perform the isolate or inhibit action, click the relevant
option
The system alerts User Programming page provides information on all of the alerts
that the user can clear or isolate. The alert signal (or input) and its current status is
displayed along with the action available to the user for each of the alert conditions.
Isolating an alert condition deactivates that system alert until it is de-isolated again.
Inhibiting an alert condition deactivates that system alert for one set period only.
NOTE
A User Duress alert can only be restored; it cannot be isolated or inhibited. The User Duress
functionality, which is triggered by entering the sum of PIN code + 1 at the Keypad, must be enabled
in Engineer Programming for this feature to work.
A complete list of the Expanders detected on the system is at Status->
Expanders. Upon clicking any of the identifying parameters (ID, description, type,
serial number), further status and options appear.
A complete list of the Keypads detected on the system is at Status-> Keypads.
Upon clicking any of the Keypad identifying parameters (ID, description, type, serial
number), further status and options for Keypads provide the following:
Communication: Input and Status revealed. Isolate/de-isolate is an option.
Cabinet Tamper: Faults and Status revealed. Isolate/de-isolate is an option.
PACE: check this box to disable key presses on a Keypad when the entry timer
is running; this applies only to Keypads with a PACE receiver installed
Panic: check this box to enable the Keypad Panic Alarm option. A Panic alarm
is generated (All bells, strobes activated) if the left and right soft programming
keys on the Keypad are pressed simultaneously.
09.2008