hit counter script

Micro Compatibility; Reader-To-Micro Wiring Distance; Keypad Operation: Model 245 - GE 240 Installation Manual

Contactless smart card reader
Hide thumbs Also See for 240:
Table of Contents

Advertisement

When installing two readers back-to-back on a wall that will separate
the two readers by four inches (101.60 mm) or less, a metal plate (for
example: Reader isolation plate, metal wall) must be placed between
the readers. To obtain the maximum read range, mount each GE
Model 24x Smart Card Reader onto one or more Isolation Spacers.
Note: Two readers can simultaneously read the same badge or tag if the
distance between the two readers is less than four inches (101.60 mm),
back-to-back.

Micro Compatibility

Micro/5 Controller with either 2RP or 8RP Reader Boards: refer to
the Micro/5 Installation Guide.
IMPORTANT: DO NOT use the GE Model 24x Readers with the Micro/5 2SRP.
Micro/PX-2000 and Micro/PXN-2000 controllers: refer to the Micro/
PX-2000 and Micro/PXN-2000 Installation Guide.
Micro/Reader-Junction Box: refer to the point-to-point wiring
diagrams in this manual.

Reader-to-Micro Wiring Distance

Supply Voltage
Model 240 and 245
Current
105 mA @12 VDC

Keypad Operation: Model 245

The reader sends each key press to the microcontroller and the yellow
LED will blink. The reader beeper sounds with each key press.
Table 1: Current and Cable Distance
12 VDC
18 AWG
2,041 ft.
(622 m)
GE Contactless Smart Card Reader Model 24x
Cable Distance
13.6 VDC
22 AWG
18 AWG
856 ft.
3,123 ft.
(262 m)
(952 m)
22 AWG
1,309 ft.
(399 m)