SDH VC Configuration Parameters for SAToP
clock source internal
tug-3 1
mode E3
threshold b3-tca 0
overhead c2 0
e3 clock source internal
e3 framing g751
!tug-3 2mode T3
threshold b3-tca 0
overhead c2 0
t3 clock source internal
t3 framing c-bit!
SDH VC Configuration Parameters for SAToP
The following parameters affect SDH VC configuration:
• BERT — Starts the BERT test.
• CEM Group — Specifies the time slots for CEM group mapping.
• Clock — Specifies the clock source for VC.
• Loopback — Sets the VC in the loopback mode.
• Overhead — Configures VC line path overhead flags.
• Shutdown — Disables the VC interface.
Configuring VC Parameters
To configure VC parameters:
enable
configure terminal
controller sdh 0/0/16
rate stm4
au-3 1
mode vc1x
tug-2 1 payload vc11
vc 1 loopback [local | network]
vc 1 clock source internal
vc 1 overhead j2 expected [16
vc 1 overhead j2 expected message STRING
vc 1 overhead j2 tx [16
vc 1 overhead j2 tx message STRING
vc 1 overhead v5 [0 - 7]
vc 1 [threshold bip2-sd 4 | threshold bip2-sf
end
v5 overhead should match with the far end tx v5.
Note
Verifying VC Configuration Parameters Configurations
Use show running-configuration command to verify VC configuration parameters configuration:
#show running-configuration
controller SDH 0/0/16
1 port OC-48/ 4 port OC-12/OC-3 + 12 port T1/E1 + 4 port T3/E3 CEM Interface Module Configuration Guide, Cisco
IOS XE Fuji 16.7.x (Cisco NCS 4200 Series)
32
| 64]
| 64]
4 | threshold bip2-tca 9]
Configuring SDH