  • Page 1 Natural Gas to L.P. Gas Conversion Kit For Bosch 80% AFUE Gas Furnace, BGS80 Model Installation Instructions 3124627...
  • Page 2 2 | Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change without prior notice. | 05.2018 Bosch Thermotechnology Corp.
  • Page 3: Table Of Contents

    2.5 Reinstalling the Burner Assembly 2.6 Pressure Gauge Installation 2.8 Checking the Manifold Pressure 2.9 Adjusting the Manifold Pressure 2.10 Removing the Pressure Gauge or U-Tube Manometer 2.11 Completing the Conversion Data subject to change without prior notice. | 05.2018 Bosch Thermotechnology Corp.
  • Page 4: Key To Symbols And Safety Instructions

    1 Key to Symbols and Safety Instructions 1.2 Safety Instructions The conversion kit supplied with the Bosch 80% AFUE Gas Furnace BGS80 model 1.1 Key to Symbols is only to be used for gas furnace installations to convert a natural gas furnace to a propane (LP) gas application for elevations less than 2000 ft.
  • Page 5: Gas Conversion Procedure

    Remove the wires from the terminals of the gas valve. Remove supply gas piping from the gas valve. All Bosch 80% AFUE Gas Furnaces come standard with Natural Gas to LP Conversion Kits. These kits are only applicable for units installed at elevations between 0 and 2,000 feet.
  • Page 6: Reinstalling The Burner Assembly

    fl ame to check for gas leaks. Reconnect the wires to the gas valve terminals. Reconnect the igniter at the 2 position plug. Reconnect the fl ame sensor wire. Data subject to change without prior notice. | 05.2018 Bosch Thermotechnology Corp.
  • Page 7: Checking The Manifold Pressure

    Turn ON the electrical power to the unit. Turn ON the main gas supply to the unit at the manual shut-off valve, which is located outside of the unit. Figure 4 Burner inspection Data subject to change without prior notice. | 05.2018 Bosch Thermotechnology Corp.