Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Preface What the consignment contains The following components are supplied with the CP 5613 A3 / CP 5614 A3: ● Communications processor CP 5613 A3 or communications processor CP 5614 A3 ● SIMATIC NET DVD including – SIMATIC NET PC software –...
Page 4
Service & Support at any time and from any location in the world. You will find this on the Internet at the following address: (http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo2&aktprim=99&lang= CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
Page 5
(http://www.automation.siemens.com/partner/guiwelcome.asp?lang=en) SITRAIN - Siemens training for automation and industrial solutions With over 300 different courses, SITRAIN covers the entire Siemens product and system spectrum in the field of automation and drive technology. Advanced training tailored to your needs is also available. In addition to our classic range of courses, we also offer a combination of various training media and sequences.
Table of contents Preface ..............................3 Description of the device ........................... 9 Properties of the CP 5613 A3 ......................9 Properties of the CP 5614 A3 ......................10 PROFIBUS interface........................11 Meaning of the LED display ......................13 Software installation..........................15 Installing the SIMATIC NET PC software ..................15 Uninstalling the SIMATIC NET PC software................15...
Description of the device Properties of the CP 5613 A3 Properties The CP 5613 A3 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. The essential properties are as follows: ● Transmission speeds up to 12 Mbps.
The CP 5614 A3 is a communications processor for connecting PCs (personal computers) or PGs (programming devices) to PROFIBUS and MPI networks. In addition to the properties of the CP 5613 A3, the CP 5614 A3 also has the following features: ● Additional PROFIBUS connection as DP slave to a second DP network.
(PB2, slave only) or both PROFIBUS connectors at the same time. You can obtain these connectors, for example, under the following order numbers: • 6GK1 500-0FC10 • 6GK1 500-0EA02 CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
Page 12
RTS output signal of the CP module. The control signal is "1" Output active when the device (PG or PC) is sending. Shield The shield is connected to components of the connector housing. CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
Applies only to Yellow on: Shows polling by the higher-level DP master. DP slave operation Yellow off: DP slave connector is not addressed. with the CP 5614 A3 CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
Page 14
Description of the device 1.4 Meaning of the LED display CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
1. Follow the instructions of the Hardware Wizard of Windows. 2. Do activate the search for drivers on the Internet. Uninstalling the SIMATIC NET PC software Condition The SIMATIC NET PC software is installed on the PG/PC. CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
Page 16
"SIMATIC NET, PC Software". You will find the installation manual on the SIMATIC NET DVD or on the Product Support pages under the following entry ID: 42784913 (http://support.automation.siemens.com/WW/view/en/42784913) CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
The CP must sit firmly and uniformly in the slot. Check that the module sits firmly in the slot as described in the manual accompanying your PG/PC. Note Oblique installation position is permitted Some PG/PC designs require oblique installation of the CP. This is permitted. CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
The plug and play function of Windows automatically searches for a driver. 8. Follow the instructions of the Hardware Wizard of Windows. activate the search for drivers on the Internet. CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
Hardware installation 3.3 Hardware compatibility Hardware compatibility Compatibility with predecessor versions The CP 5613 A3 can replace the following predecessor versions: ● CP 5613 A2 ● CP 5613 The CP 5614 A3 can replace the following predecessor versions: ● CP 5613 A2 and CP 5614 A2 ●...
Compatibility during configuration If there is not yet a CP 5613 A3 / CP 5614 A3 available in the hardware catalog of your STEP 7 version or NCM PC version, you can also select one of the following CPs for configuration: ●...
Page 24
Technical specifications Technical specifications CP 5613 A3 / CP 5614 A3 Storage and transportation conditions Temperature (EN 60068-2-1+2) -20...+60°C Temperature change max. ≤20 K/h Rel. humidity (EN 60068-2-78) ≤ 95% at +25...+55°C no condensation Fast temperature change -20...+60°C, 2 cycles to EN 60068-2-14 •...
If the communications processor is part of the equipment of a machine, it must be included in the procedure for obtaining the declaration of conformity by the manufacturer of the machine. C-TICK approval The communications processor meets the requirements of the Australian AS/NZS 3548 standard. CP 5613 A3 / CP 5614 A3 Operating Instructions, 10/2012, C79000-G8976-C277-01...
Page 26
● Consult the dealer or an experienced radio/TV technician for help. Siemens AG is not responsible for any radio television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Siemens AG. The correction of interference caused by such unauthorized modification, substitution or attachment will be the responsibility of the user.