Page 1
Preface Safety instructions Description SIMOTION Application planning SIMOTION P320-4 E / P320-4 S Interfaces Installation/mounting Manual Connection Troubleshooting/FAQs Technical data Dimension drawings Spare parts Standards and approvals ESD Guideline Valid as of version V4.4 01/2015...
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
● SIMOTION P320-4 E / P320-4 S, Commissioning and Hardware Installation Manual, Edition 01/2015 Validity range This manual applies to the SIMOTION P320-4 E and SIMOTION P320-4 S devices as of product level SIMOTION V4.4. Standards The SIMOTION system was developed in accordance with ISO 9001 quality guidelines.
Page 4
● SIMOTION Engineering System Handling ● SIMOTION System and Function Descriptions ● SIMOTION Service and Diagnostics ● SIMOTION IT ● SIMOTION Programming ● SIMOTION Programming - References ● SIMOTION C ● SIMOTION P SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 5
● Using documentation online (find and search manuals/information) http://www.siemens.com/motioncontrol/docu My Documentation Manager Click the following link for information on how to compile documentation individually on the basis of Siemens content and how to adapt it for the purpose of your own machine documentation: http://www.siemens.com/mdm Training...
Page 6
If you have any further questions about disposal and recycling, please contact your local Siemens contact person. Contact details can be found in our contacts database on the Internet at: http://www.automation.siemens.com/partner/index.asp SIMOTION P320-4 E / P320-4 S...
Unpacking and checking the delivery..................37 Identification data of the device....................39 Permissible mounting positions....................42 Environmental conditions.......................43 Electromagnetic compatibility....................45 Interfaces..............................47 Hardware components of the SIMOTION P320-4..............47 Overview of operator control and display elements...............49 Control elements........................50 Status displays........................51 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 8
Overview of the technical specifications................87 General technical specifications.....................88 Ambient conditions.........................90 Technical data of the IsoPROFIBUS board................92 Power requirements of the components................94 Integrated DC power supply....................95 Technical data for the SITOP smart 24 V/10 A..............96 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 9
Spare parts...............................107 10.1 Available spare parts for SIMOTION P320-4...............107 Standards and approvals..........................109 General rules........................109 ESD Guideline............................111 ESD definition........................111 Electrostatic charging of individuals..................112 Basic measures for protection against discharge of static electricity........113 Index.................................115 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 10
Table of contents SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Touching live components can result in death or severe injury. ● Only use power supplies that provide SELV (Safety Extra Low Voltage) or PELV (Protective Extra Low Voltage) output voltages for all connections and terminals of the electronics modules. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 12
● Install devices without a protective housing in a metal control cabinet (or protect the device by another equivalent measure) in such a way that contact with fire inside and outside the device is prevented. ● Ensure that smoke can only escape via controlled and monitored paths. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 13
● Ensure that the safety functions used in your drives and automation tasks are adjusted and activated through appropriate parameterizing. ● Perform a function test. ● Only put your plant into live operation once you have guaranteed that the functions relevant to safety are running correctly. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
– Wearing ESD shoes or ESD grounding straps in ESD areas with conductive flooring ● Only place electronic components, modules or devices on conductive surfaces (table with ESD surface, conductive ESD foam, ESD packaging, ESD transport container). SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept.
Page 16
5. Release of environmental pollutants or emissions as a result of improper operation of the system and/or failure to dispose of components safely and correctly. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 17
Assuming that conductive contamination at the installation site can definitely be excluded, a lower degree of cabinet protection may be permitted. For more information about residual risks of the components in a drive system, see the relevant sections in the technical user documentation. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Note that the device is classified as "Open Type" for use in the area of Industrial Control Equipment (UL508). Installation of the device in an enclosure according to UL508 is conditional for approval or operation according to UL508. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 19
When you touch electrostatic sensitive components, you can destroy them through voltages that are far below the human perception threshold. If you work with components that can be destroyed by electrostatic discharge, observe the ESD Guideline. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
● Do not obstruct the venting slots of the device. Note Use in an industrial environment without additional protective measures This device was designed for use in a normal industrial environment according to IEC 60721-3-3. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
PLC, motion control and technology functions on account of the increasing use of servo drives: ● Packaging machines ● Plastic and rubber processing machines ● Presses, wire-drawing machines ● Textile machines SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 22
Description 2.1 System overview ● Printing machines ● Machines for processing wood, glass, ceramics, and stone ● Production lines in the renewable energy sector, e.g. solar technology, wind power installations SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
● Graphics memory is claimed in main memory (dynamic UMA) Power supply 24 VDC (-20%/+20%) max. 4 A Operating conditions Operation without fan Drives and storage media CFast card or SSD (Solid State Disk) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 25
1 × RJ45 (10/100/1000 Mbps) PROFINET I/O 3 × RJ45 (100 Mbps) Keyboard, mouse Can be connected via USB interface Software Operating systems P320-4 E Windows Embedded Standard 7 32-bit P320-4 S Windows 7 Ultimate 32-bit SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
SIMOTION P320-4 (hardware) structure The following figure shows the integration of the SIMOTION P320-4 with integrated PROFINET onboard and optional IsoPROFIBUS board in a target system. Figure 2-3 System overview of the SIMOTION P320-4 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
SIMOTION SCOUT Engineering System (ES). User data can be stored on the data media of the SIMOTION P320‑4. Siemens WinCC flexible software can be used to visualize operational sequences or to operate the machine. Third-party systems can be linked via the OPC interface.
SIMOTION P320‑4. HMI software HMI/Runtime software can be operated on the same PC, e.g. the Siemens WinCC flexible software. Other software packages can be linked by means of the OPC interface. The HMI software is used as the general term in the following.
Page 29
SIMOTION for the ET 200M distributed I/O system. For a detailed and routinely updated list of I/O modules enabled with SIMOTION as well as application information, visit us online at: siemens.com - Industry Automation and Drive Technologies - Product Support - Supplementary System Components (http://support.automation.siemens.com/WW/view/en/ 11886029) Further modules are integrated via the GSD file of the device's manufacturer.
Page 30
Servo drives, innovative single-axis and multi-axis solution Optional components Table 2-3 Optional components Centralized I/O Function IsoPROFIBUS board PROFIBUS connection Uninterruptible Power Supply Note In addition, an IsoPROFIBUS board may be inserted for the PROFINET onboard. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
SIMOTION P320-4 S. For this model, you must set the communication (access point) to PC internal. The SIMOTION P320-4 is already configured for this communication variant at the time of delivery. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Description 2.3 HMI and SIMOTION SCOUT Figure 2-4 Set PG/PC Interface dialog Note Only HMI-Runtime can be installed on the SIMOTION P320-4 E version. Figure 2-5 Model: Local HMI or ES 2.3.3 HMI or ES via PROFINET Networking via PROFINET PROFINET is the innovative and open Industrial Ethernet standard (EN 61158) for industrial automation.
This allows both an external HMI or ES to access several SIMOTION devices or one SIMOTION device to access another one, for example, to display the production data. Figure 2-7 Model: Networking via Ethernet SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
HMI or ES via IsoPROFIBUS (optional) Networking via PROFIBUS DP If you connect a central HMI via PROFIBUS DP, the X101 and X102 interfaces of the IsoPROFIBUS board are available. Figure 2-8 Model: Networking via PROFIBUS DP SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 35
Description 2.3 HMI and SIMOTION SCOUT References You can find further information on the HMI in the documentation: ● SIMOTION Runtime Basic Functions, section HMI (Human Machine Interface) coupling. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 36
Description 2.3 HMI and SIMOTION SCOUT SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Do not dispose of the original packaging. Pack the device for transport and storage in the original packaging. 5. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 38
7. Please keep the enclosed documentation, it belongs to the device. You need the documentation when you commission the device for the first time. 8. Write down the identification data of the device. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
● Serial number S VP<...> The computing unit is uniquely identifiable with the serial number at S VP <...>. <...> <...> is an 8-digit character string. ● cULus Approval ● CE marking SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 40
Onboard MAC addresses for: ● ETHERNET (LAN) X1: VIPCTYSMAC1 ● PROFINET (LAN) X3: VIPCTYSPROFINET The data cited here is not real data. Figure 3-2 Type plate SIMOTION P320-4 S - MAC addresses SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 41
7 or Windows 7 operating system. ● COA label of a device with Windows Embedded Standard 7 32-bit operating system Figure 3-3 ipc477d label coa 01 ● COA label of a device with Windows 7 operating system SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Application planning 3.3 Permissible mounting positions Permissible mounting positions Information on the permissible mounting positions for the SIMOTION P320-4 can be found in the section Installation/mounting > Permissible mounting positions (Page 64). SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
● Installations requiring special monitoring such as: – Elevator installations – Electrical plants in particularly hazardous areas An additional measure for using the SIMOTION P320-4 could be its installation in a cabinet. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 44
Application planning 3.4 Environmental conditions Ambient conditions For the mechanical and climatic environmental conditions, refer to the technical specifications in the section Ambient conditions (Page 90). SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Electromagnetic compatibility Definition Standards for electromagnetic compatibility (EMC) are fulfilled if the EMC Installation Guideline is complied with. See also: Further information is provided in the Appendix, Section General regulations (Page 109). SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 46
Application planning 3.5 Electromagnetic compatibility SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The power supply must satisfy the requirements as described in section Connecting the power supply (24 VDC) (Page 81). This can be ensured by using the following devices, for example: ● SITOP smart 24 V / 10 A ● 24 VDC UPS (optional) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 48
(hot swapping, etc.) are not supported by SIMOTION for the ET 200M distributed I/ O system. A detailed and routinely updated list of I/O modules released for SIMOTION as well as instructions on their use is provided on the Internet at Siemens Product Support (http:// support.automation.siemens.com/WW/view/en/11886029).
Overview of operator control and display elements The following figure shows the arrangement of the indication and control elements of the SIMOTION P320-4. ① On/Off switch ② Operating displays (LEDs) Figure 4-1 SIMOTION P320-4 control and display elements SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
To remove power from the device, the power supply plug must be removed. NOTICE Close down the operating system first First close down the operating system before switching off the device with the on/off switch, otherwise data may get lost. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
SIMOTION P320-4 in RUN mode. Yellow SIMOTION P320-4 in STOP mode. Green/yellow: DCP flashing Flashes quickly (2 Hz) Yellow: Flashes "FAULT" status quickly (only in combination with L2 and L3) (2 Hz) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 52
Carry out the licensing to correct the error. (0.5 Hz) Further information on the licensing can be found in the SIMOTION P320-4 E / SIMOTION P320-4 S Commis‐ sioning and Hardware Installation Manual. Red: Flashes quickly A fault has occurred to which the user program cannot (2 Hz) respond.
Receive data Output 7, 8 SYMT- Internal 75 Ohm terminating resistor Shield LED 1 Lights up green: Link LED 2 Lights up yellow: Activity Optional product feature Autonegotiation and autocrossover are supported. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Lit: Active connection, e.g., to a hub – Flashing: Activity Note The interfaces available on the device have been numbered for unique identification. This numbering may deviate, however, from the numbering assigned by the operating system. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Cable shield TMDS clock shield Cable shield TMDS clock+ DVI clock channel Output TMDS clock- DVI clock channel Output Analog red (R) Analog red signal Output Analog green (G) Analog green sig‐ Output SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 57
4.8 DVI-I DVI-I interface (standard socket) Analog blue (B) Analog blue signal Output Analog horizontal sync Analog horizontal Output (HSYNC) sSync signal Analog ground (analog R, Analog ground G, & return) (GND) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Short description Meaning Input/output VBUS + 5 V (fused) Output Data line Input/output Data line Input/output Ground – Data line Input Data line Input Ground – Data line Output Data line Output SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Meaning Input/output Data carrier detect Input Receive data Input Transmit data Output Data terminal ready Output Ground Data set ready Input Request to send Output Clear to send Input Incoming call Input SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Data line (I/O) RTS_AS Turn on PLC transmitter (O) Ground isolated P5V_dp_fused +5 V / max. 90 mA (fused) electrically isolated Not connected LTG_A Data line (I/O) RTS_PG PG Request to send (O) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 62
Interfaces 4.12 IsoPROFIBUS board (optional) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The correct use of the device has to be verified with a function test on the system. This test can detect programming, configuration and wiring errors. The test results have to be documented and if necessary inserted into the relevant inputs. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The interfaces are at the bottom. The figure shows the interfaces on the front for representation purposes only. For rail mounting, the interfaces always point downward. You can find mounting information under Standard rail mounting (Page 65). SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Ensure that the wall or ceiling can hold four times the total weight of the SIMOTION P320-4 including the standard mounting rail and additional expansion cards. See section Notes on installation (Page 69). SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 66
● 1 standard mounting rail clip ● 2 screws ● 1 T20 screwdriver Use the two screws to mount the standard mounting rail clip on the SIMOTION P320-4 enclosure. Figure 5-1 Mounting the standard mounting rail clip SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
3. Lift the device up and off. 5.2.1.2 Vertical mounting The fasteners and screws required are supplied with the device for the selected mounting option. Requirement ● 2 mounting brackets ● 4 screws ● 1 T20 screwdriver SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 68
Installation/mounting 5.2 Permissible mounting positions Procedure 1. Secure each mounting bracket with two screws. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The device may not be securely fitted if you use dowels and screws other than those specified below for mounting. The device can fall and may be damaged. Use only the dowels and screws specified in the following table. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 70
Mounting positions The following mounting positions are permitted for the SIMOTION P320-4 and are described in detail in the following sections: ● Standard rail mounting (Page 65) ● Vertical mounting (Page 67) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
5. Mount the SIMOTION P320-4. Note The installation and removal of components as well as the mounting of the SIMOTION P320-4 are described in detail in the SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual. NOTICE Avoid loss of warranty If you install or exchange system expansions and damage your device, the warranty becomes void.
USB or DVI connection. Please note the cable lengths that are supported for the panel. For the use of an HMI system, the SIMATIC IFP, for example, can be connected by means of the described interfaces. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The following section provides information on wiring and networking the complete SIMOTION system. Further information about the connection of the complete system and the individual components can be found in the SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual Open equipment These modules are open equipment.
It does not matter in which order connection takes place. The connection of the individual components in the SIMOTION P320-4 E / P320-4 S Commissioning and Hardware Installation Manual. SIMOTION P320-4 E / P320-4 S...
Page 75
Connection 6.2 Overview of connections Figure 6-1 Hardware system overview - example with PROFINET onboard and optional IsoPROFIBUS board SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
● Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. ● I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 77
Regenerative feedback of voltage to ground by a connected or installed component can damage the device. Connected or built-in I/Os, for example, a USB drive, are not permitted to supply any voltage to the device. Regenerative feedback is generally not permitted. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
● Take a faulty device out of service immediately and mark it accordingly. Requirement ● The device has been installed. ● 1 protective conductor, minimum cross section 2.5 mm ● 1 T20 screwdriver ● 1 x M4 cable lug SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 79
2. Screw the cable lug onto the protective conductor connection as shown. ① Protective conductor connection / potential equalization 3. Wire the protective conductor to the protective conductor connection of the control cabinet in which the device is installed. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The connected or built-in I/Os, such as USB drives, should not introduce a counter EMF into the device. Reverse voltages exceeding 0.5 V to ground that are generated by connected or installed components may prevent proper operation of the device or lead to its destruction. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
0.25 mm² to 2.5 mm². Only connect wires with a cross-section ≥ 0.5 mm². Solid or flexible cables can be used for the connection. Ferrules are not required. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 82
6.6 Connecting the power supply (24 VDC) Procedure 1. Connect the cables as shown. Note the position of the terminal. 2. Insert the terminal at the marked po‐ sition. 3. Secure the terminal using the integra‐ ted screws. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
You will need SIMOTION SCOUT, STEP 7, WinCC, WinCC flexible, WinAC and SIMATIC NET. Further information Further information is available on the Internet at the Siemens Industry Mall (www.siemens.com/industrymall), the catalog and ordering system for automation and drives. SIMOTION P320-4 E / P320-4 S...
Maximum cable tie width 3 mm. ● 1 cutting tool Procedure 1. Place the cable tie around the attachment plate of the strain-relief assembly and secure the plugged-in cables. 2. Cut off the cable tie overhang. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The backup battery is Replace the backup battery. is OK, the time and date empty. (See SIMOTION P320-4 E / P320-4 S Commissioning and Hard‐ are still wrong. ware Installation Manual > Service and maintenances > Replacing the back-up battery).
Page 86
Troubleshooting/FAQs 7.1 Error correction SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
● Power requirement of the components (Page 94) ● Integrated DC voltage supply (Page 95) ● Technical specifications of the SITOP smart 24 V / 10 A (Page 96) ● Typical power consumption (Page 98) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
1 V/m 2–2.7 GHz, 80% AM according to IEC 61000-4-3 10 V 10 kHz to 80 MHz, 80% AM according to IEC 61000-4-6 Immunity to magnetic fields 100 A/m, 50/60 Hz according to IEC 61000-4-8 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
"Advanced CPU Control", of the BIOS Setup; otherwise you have to reduce the maximum ambient temperature by 5 °C. RAL = Restricted Access Location Installation of device in operating facilities with restricted access, for example, a locked control cabinet. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 91
- During storage/shipping 5 to 9 Hz: 3.5 mm 9 to 500 Hz: 9.8 m/s2 Resistance to shock Tested according to DIN IEC 60068-2-27 - During storage/shipping 250 m/s , 6 ms SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Weight 150 g Space requirements Short PCI slot Safety Safety Degree of protection IP20 in mounted state Protection class I complies with VDE 0106 Safety regulations EN 60950 Approvals CE, UL508, cULus SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 93
8.4 Technical data of the IsoPROFIBUS board Quality assurance Quality assurance complies with ISO 9001. Note The safety regulations, approvals, protection type and protection class specified are valid only if the module is inserted in a SIMOTION P320-4. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The total power of the PCI and USB cards may not exceed 15 W Note Device can overheat! To avoid overheating, the power loss per PCI slot should not exceed 5 watts. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
The peak value of the startup current depends on the input voltage and the impedance of the 24 V power source. Peak currents greater than 6.5 A are possible. This will not have a negative impact on device functionality. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Class I Primary/secondary galvanic isolation SELV output voltage according to EN 60950 and EN 50178; transformer according to EN 61558-2-17; overvoltage protection in the event of an internal error < 60 V SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 97
UL 508 (Listed, File E197259); CSA C22.2 No 14, No 60950-1-03 Shipbuilding Germanischer Lloyd Directive 94/9/EC Declaration of conformity according to EN 60079‑15: ATEX94/9/EC Cat.3;Eex, nA, II, T4 U C‑Tick AS/NZS 2064:1997 Article numbers 6EP1334‑2AA01, 6EP1334‑2BA01 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
120 mA USB expansion Max. 500 mA Max. 12 W PCI expansion Max. 500 mA Max. 12 W The total power of the PCI and USB expansion may not exceed 15 W SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Overview of the dimensional drawings This section contains the dimension drawings for the SIMOTION P320-4: ● Standard rail mounting (Page 100) ● Vertical mounting (Page 102) ● SIMOTION P320-4 with an expansion card (Page 105) SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Device dimension drawing for standard rail mounting Various views of the standard rail mounting with dimensions are shown in the following: Figure 9-1 Standard rail mounting, bottom view Figure 9-2 Standard rail mounting, front view SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 101
Dimension drawings 9.2 Device dimension drawing for standard rail mounting 83.7 92.2 Figure 9-3 Standard rail mounting, side left view Figure 9-4 Standard rail mounting, rear view All dimensions in mm. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
9.3 Device dimension drawing for vertical mounting Device dimension drawing for vertical mounting Various views of the vertical mounting with dimensions are shown in the following: Figure 9-5 Vertical mounting, front view SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 103
Dimension drawings 9.3 Device dimension drawing for vertical mounting Figure 9-6 Vertical mounting, front side view SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 104
Dimension drawings 9.3 Device dimension drawing for vertical mounting Figure 9-7 Vertical mounting, rear side view Figure 9-8 Vertical mounting, view from above All dimensions in mm. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
9.4 Dimension drawing of device with one expansion card Dimension drawing of device with one expansion card Device with one expansion card Figure 9-9 Standard rail mounting, bottom SIMOTION P320-4 - Side views SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 106
Dimension drawings 9.4 Dimension drawing of device with one expansion card SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Spare parts 10.1 Available spare parts for SIMOTION P320-4 You can order the accessories via the Siemens Industry Mall (www.siemens.com/ industrymall). The following spare parts are available for SIMOTION P320-4: Spare parts for SIMOTION P320-4 Spare parts Article number Scope of delivery...
Page 108
Spare parts 10.1 Available spare parts for SIMOTION P320-4 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
EMC-compliant configuration of the plant are described in this Manual and/or the "EMC Installation Guideline" Configuration Manual. Please note that ultimately it is always the label on the device that provides the decisive information on the compliance with standards. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 110
Standards and approvals A.1 General rules Declaration of conformity The current Declaration of conformity is available on the Internet at Declaration of conformity (http://support.automation.siemens.com/WW/view/en/10805446/134200). SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
– Wearing ESD shoes or ESD grounding straps in ESD areas with conductive flooring ● Only place electronic components, modules or devices on conductive surfaces (table with ESD surface, conductive ESD foam, ESD packaging, ESD transport container). SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
This figure indicates the maximum electrostatic charges that can accumulate on an operator when he comes into contact with the indicated materials. These values comply with the specifications in IEC 801-2. Figure B-1 Electrostatic voltage that can accumulate on operating personnel SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
If you have to take measurements on a module, make sure that you first discharge any static that may have accumulated in your body. To do this, touch a grounded metal object. Only use grounded measuring instruments. SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 114
ESD Guideline B.3 Basic measures for protection against discharge of static electricity SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
SIMOTION P320-4, 85 Functional test SIMOTION P320-4, 63 Data exchange, 83 DC power supply, 95 Decentralized structure SIMOTION P320-4, 72 General technical specifications Declaration of conformity, 110 SIMOTION P320-4, 88 Degree of protection, 88 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 116
USB 3.0, 58 SIMOTION P320-4, 75 Interference emission, 88 Overview of the interfaces IsoPROFIBUS board SIMOTION P320-4, 53 SIMOTION P320-4, 107 Technical specifications, 92 IT communication, 83 P320-4 E Operating system, 25 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 117
Transportation, 38 Overview of connections, 75 Safety instructions Overview of the interfaces, 53 SIMOTION P320-4, 18 PROFINET interface, 54 Serial number Protective conductor connection, 79 SIMOTION P320-4, 39 Radiation, 19 Safety instructions, 18 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...
Page 118
IsoPROFIBUS board, 92 Motherboard, 89 Power consumption, 88 SITOP smart 24 V/10 A, 96 Supply voltage, 88 Weight, 88 Technical specifications interfaces, 89 Troubleshooting/FAQs, 85 Type plate SIMOTION P320-4 S, 39 UL certification, 109 SIMOTION P320-4 E / P320-4 S Manual, 01/2015...