Installing
4.1
Installing the device
Optional installation locations
The device can be mounted horizontally or vertically in control desks, switching cabinets and
19" rack systems.
Optional mounting methods
Function test while installing the device in machines or systems
Following the results of a risk analysis, additional protection equipment on the machine or
the system is necessary to avoid endangering persons. With this, especially the
programming, configuration and wiring of the inserted peripherals have to be executed, in
accordance with the safety performance (SIL, PL or Cat.) identified by the necessary risk
analysis.
The intended use of the device has to be ensured.
The proper use of the device has to be verified with a function test on the system. This test
can detect programming, configuration and wiring errors. The test results have to be
documented and if necessary inserted into the relevant inputs.
Options of mounting the device
● Mounting on cabinet brackets
● Mounting on device bases
● Tower installation: a tower kit can be ordered separately for this (not available in some
● Mounting on telescopic rails
When telescopic rails are used for mounting, the device can be withdrawn fully from the
cabinet or rack.
For detailed information on telescopic rails, see the sections Technical data of the telescopic
rails and Dimensional drawing for the use of telescopic rails.
SIMATIC IPC847C
Getting Started, 12/2010, A5E02669190-02
WARNING
countries)
Figure 4-1
Position of the mounting holes
4
21