Power
If ac power fails
If ac power fails
If the automatic shutdown feature has been enabled, follow the
procedure in "ac power failure with automatic shutdown enabled". If the
automatic shutdown feature is disabled, follow the procedure in "ac
power fails without automatic shutdown enabled" on page 65.
ac power failure with automatic shutdown
enabled
1. You will hear an alarm (a single beep every 10 seconds). If desired,
CAUTION
Do NOT press the switch on the PowerTrust UPS labeled Output On/
Output Off. Pressing this switch would shut off power to the node.
2. With the OS properly configured for UPS, you will see UPS messages
3. The indicators on the PowerTrust UPS front panel labeled AC Output
If ac power does not return
If ac power does not return within the time specified by the parameter,
shutdown_delay_mins (default = 1 minute), the shutdown(1M)
command with the -h option is executed. Normal shutdown processing
occurs. In case the shutdown process changes, the reboot command with
the halt option is executed after an interval specified by
shutdown_delay_mins (default = 5 minutes).
CAUTION
Do not turn off power yourself, no matter what messages you see on the
console. Power will be turned off automatically as part of the automatic
shutdown. If you turn off power yourself, the system may be powered off
automatically as it is rebooting, causing a hard crash.
64
you can turn off the auditory alarm by pressing the switch on the
PowerTrust UPS labeled Silence Alarm.
on the console. See Appendix A in PowerTrust System Guide (PN
3329-90002) for explanations of the messages.
and Battery Power will be lit.
Chapter 6