Page 2
Preface S7-1500R/H Documentation Guide SIMATIC Product overview Connecting S7-1500R/H CPU 1515R-2 PN Interrupts, diagnostics, error messages and system (6ES7515-2RM00-0AB0) events Equipment Manual Technical specifications Dimension drawing 11/2019 A5E42009914-AB...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Preface Purpose of the documentation This manual supplements the system manual of the S7-1500R/H redundant system and the function manuals. This manual contains a description of the module-specific information. The system-related functions are described in the system manual. All system-spanning functions are described in the function manuals.
Page 5
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
Page 6
Preface Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP). You can find catalogs for all automation and drive products on the Internet (https://mall.industry.siemens.com).
Table of contents Preface ..............................3 S7-1500R/H Documentation Guide ......................7 Product overview ............................9 New functions in firmware version V2.8 ................... 9 Configuration and operating principle ..................11 Hardware properties ......................13 Firmware functions ......................... 17 Operator controls and display elements ................20 2.5.1 Front view of the CPU with closed front panel ...............
S7-1500R/H system, e.g. diagnostics, communication. You can download the documentation free of charge from the Internet (https://support.industry.siemens.com/cs/ww/en/view/109742691). Changes and supplements to the manuals are documented in a Product Information. You can download the product information free of charge from the Internet (https://support.industry.siemens.com/cs/ww/en/view/109742691).
Page 9
You must register once to use the full functionality of "mySupport". You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/en/). Application examples The application examples support you with various tools and examples for solving your automation tasks.
You can download a modified user program into the S7-1500R/H System Manual program in RUN- R/H CPUs in the RUN-Redundant system state. (https://support.industry.siemens.com/c Redundant system state s/ww/en/view/109754833) Advantage: The redundant system will remain con- sistently in the RUN-Redundant system state during the change to the user program.
Page 11
PID controllers are built into all R/H-CPUs as stand- S7-1500R/H System Manual • ard. PID controllers measure the actual value of a (https://support.industry.siemens.co physical variable, for example, temperature or pres- m/cs/ww/en/view/109754833) sure, and compare the actual value with the setpoint.
Product overview 2.2 Configuration and operating principle Configuration and operating principle Structure The S7-1500R redundant system consists of the following components: ● Two CPUs of the type CPU 1515R-2 PN ● Two SIMATIC memory cards ● PROFINET cable (redundancy connections, PROFINET ring) ●...
Page 13
You mount the CPUs on a standardized 35 mm rail using the standard rail adapter. You will find information on mounting the standard rail adapter in the S7-1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. Principle of operation One of the two CPUs in the redundant system takes on the role of CPU for process control (primary CPU).
Product overview 2.3 Hardware properties Hardware properties Article number 6ES7515-2RM00-0AB0 View of the module The figure below shows the CPU 1515R-2 PN. Figure 2-2 CPU 1515R-2 PN Note Protective film Note that there is a removable protective foil on the display when the CPUs are delivered. CPU 1515R-2 PN (6ES7515-2RM00-0AB0) Equipment Manual, 11/2019, A5E42009914-AB...
Page 15
All CPUs of the redundant system S7 1500R/H have a Redundant System S7-1500R/H • display with plain text information. The display provides (https://support.industry.siemens. you with diagnostic messages as well as information com/cs/ww/en/view/109754833) about the article number, the firmware version and the System Manual serial number of the CPU.
Page 16
The CPU has an X1 interface with two ports (X1 P1 R Redundant System S7-1500R/H • (X1 P1 R and X1 P2 R) and X1 P2 R). (https://support.industry.siemens. com/cs/ww/en/view/109754833) The PROFINET IO interface X1 (default P1 R) is • System Manual used to set up the PROFINET ring with the two CPUs and the IO devices.
Page 17
H-Sync Forwarding when the "ApplicationClass" attribute contains the "HighAvailability" token. You will find more information on H-Sync Forwarding in the system manual S7-1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833). Accessories You can find information on the topic of "Accessories/spare parts" in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833).
Additional information CPU redundancy There are two duplicate CPUs that synchronize their Redundant System S7-1500R/H data via redundancy connections within a PROFINET (https://support.industry.siemens.com/ ring. If one of the CPUs fails, the other CPU retains cs/ww/en/view/109754833) System control of the process. Manual...
Page 19
Additional information RT (real time) RT prioritizes PROFINET IO frames over standard Function manual PROFINET frames. This ensures the required determinism in the (http://support.automation.siemens.co automation technology. In this process the data is m/WW/view/en/49948856) transferred via prioritized Ethernet frames. MRP (Media Redundancy...
Page 20
Additional information Security Integrated Know-how protection The know-how protection protects user blocks Redundant System S7-1500R/H against unauthorized access and modifications. (https://support.industry.siemens.com/ cs/ww/en/view/109754833) System Access protection You can use authorization levels to assign separate Manual rights to different user groups. Integrity protection The CPUs dispose of integrity protection by default.
Product overview 2.5 Operator controls and display elements Operator controls and display elements 2.5.1 Front view of the CPU with closed front panel The figure below shows the front view of the CPU 1515R-2 PN. ① LEDs for the current operating state and diagnostic status of the CPU ②...
Page 22
(local lock) and assign a password for the display. You can find additional information on the display, the configurable protection levels and the local lock in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). Reference You can find detailed information on the individual display options, a training course and a simulation of the available menu commands in the SIMATIC S7-1500 Display Simulator (http://www.automation.siemens.com/salesmaterial-as/interactive-manuals/getting-...
Product overview 2.5 Operator controls and display elements 2.5.2 Front view of the CPU without front panel The figure below shows the operator controls and connection elements of the CPU 1515R-2 PN. ① LEDs for the current operating state and diagnostic status of the CPUs ②...
Product overview 2.5 Operator controls and display elements 2.5.3 Rear view of the CPU The figure below shows the connection elements on the rear of the CPU 1515R-2 PN. ① Shield contact surfaces ② Plug-in connection for power supply ③ Plug-in connection for backplane bus ④...
You can find a brief overview of the various operating states and system states in the section Status and error display of the CPU (Page 29). You can find a detailed description of the operating states and system states in the system manual for S7-1500R/H Redundant System (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1515R-2 PN (6ES7515-2RM00-0AB0) Equipment Manual, 11/2019, A5E42009914-AB...
1L+ and 2L+ as well as 1M and 2M are bridged internally. Maximum 10 A permitted You can find information on the various supply options in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1515R-2 PN (6ES7515-2RM00-0AB0) Equipment Manual, 11/2019, A5E42009914-AB...
Page 27
Additional information You can find additional information on the topic of "Connecting the CPU" and on the topic "Accessories/spare parts" in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). Assignment of the MAC addresses For each CPU, CPU 1515R-2 PN has: ●...
Page 28
Connecting 3.1 Terminal assignment The table below shows how the MAC addresses are assigned. Table 3- 2 Assignment of MAC addresses using the example of a single CPU Assignment Labeling MAC address 1 PROFINET interface X1 Front printed • (visible in STEP 7 for accessible devices) Right-side printed •...
Page 29
Connecting 3.1 Terminal assignment Block diagram The following figure shows the block diagram of the CPU 1515R-2 PN. ① SIMATIC memory card (X50) PN X1 P2 R PROFINET interface X1 port 2 ② Display PN X2 P1 PROFINET interface X2 port 1 ③...
You can find more detailed information on "Interrupts" in the STEP 7 online help. You can find additional information on the topic of "Diagnostics" and "System events" in the Diagnostics (http://support.automation.siemens.com/WW/view/en/59192926) function manual and in the system manual Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833).
Page 31
Interrupts, diagnostics, error messages and system events 4.1 Status and error display of the CPU LED displays depending on operating states and system states CPU 1515R-2 PN has the following LEDs for displaying the current operating state and diagnostics status. ●...
Page 32
Interrupts, diagnostics, error messages and system events 4.1 Status and error display of the CPU Meaning of the RUN/STOP, ERROR and MAINT LEDs CPU 1515R-2 PN has the following LEDs for displaying the current operating state and diagnostics status. Note LED patterns of the redundant system S7 1500R Note that it is not always possible to: •...
Page 33
Interrupts, diagnostics, error messages and system events 4.1 Status and error display of the CPU The following table shows the meaning of the various color combinations for the RUN/STOP, ERROR and MAINT LEDs. Table 4- 1 Meaning of the LEDs RUN/STOP LED ERROR LED MAINT LED...
Page 34
Interrupts, diagnostics, error messages and system events 4.1 Status and error display of the CPU Note MAINT LED of the two CPUs The MAINT LEDs of both CPUs only go out when the following conditions are fulfilled: • The CPUs are in the RUN-Redundant system state. •...
Technical specifications The following table shows the technical specifications as of 11/2019. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7515-2RM00-0AB0/td?dl=en). Article number 6ES7515-2RM00-0AB0 General information Product type designation CPU 1515R-2 PN HW functional status...
Page 36
Technical specifications Article number 6ES7515-2RM00-0AB0 Work memory 500 kbyte integrated (for program) • 3 Mbyte integrated (for data) • Load memory 32 Gbyte Plug-in (SIMATIC Memory Card), max. • Backup maintenance-free • CPU processing times for bit operations, typ. 60 ns for word operations, typ.
Page 37
Technical specifications Article number 6ES7515-2RM00-0AB0 Counters, timers and their retentivity S7 counter 2 048 Number • Retentivity – adjustable IEC counter Any (only limited by the main memory) Number • Retentivity – adjustable S7 times 2 048 Number • Retentivity –...
Page 38
Technical specifications Article number 6ES7515-2RM00-0AB0 Hardware configuration Number of distributed IO systems Number of IO Controllers integrated • Time of day Clock Hardware clock Type • 6 wk; At 40 °C ambient temperature, typically Backup time • 10 s; Typ.: 2 s Deviation per day, max.
Page 39
Technical specifications Article number 6ES7515-2RM00-0AB0 PROFINET IO Controller Services – PG/OP communication – S7 routing – Isochronous mode – Open IE communication – Yes; Only Manager Auto, max. 50 nodes; only 16 – are recommended, however – MRPD – PROFIenergy –...
Page 40
Technical specifications Article number 6ES7515-2RM00-0AB0 Protocols Number of connections Number of connections, max. • Number of connections reserved for • ES/HMI/web Number of S7 routing paths • Redundancy mode Yes; Manager Auto is permanently set in TIA. • Max. 50 nodes are possible, 16 are recommend- MRPD •...
Page 41
Technical specifications Article number 6ES7515-2RM00-0AB0 Media redundancy 200 ms; PROFINET MRP Switchover time on line break, typ. • 50; Only 16 are recommended, however Number of stations in the ring, max. • Isochronous mode Isochronous operation (application synchro- nized up to terminal) Equidistance S7 message functions Number of login stations for message func-...
Page 42
Technical specifications Article number 6ES7515-2RM00-0AB0 Traces Number of configurable Traces • 512 kbyte Memory size per trace, max. • Interrupts/diagnostics/status information Diagnostics indication LED RUN/STOP LED • ERROR LED • MAINT LED • Connection display LINK TX/RX • Supported technology objects Motion Control Controller Yes;...
Page 43
830 g General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc. in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1515R-2 PN (6ES7515-2RM00-0AB0) Equipment Manual, 11/2019, A5E42009914-AB...
Dimension drawing Dimension drawing This section contains the dimensional drawing of the module on the mounting rail, as well as a dimensional drawing with the front panel open. Keep to the dimensions when installing in cabinets, control rooms, etc. Dimension drawings of the CPU 1515R-2 PN Figure A-1 Dimension drawing of the CPU 1515R-2 PN, front and side view CPU 1515R-2 PN (6ES7515-2RM00-0AB0)
Page 45
Dimension drawing A.1 Dimension drawing Figure A-2 Dimension drawing CPU 1515R-2 PN, side view with open front panel CPU 1515R-2 PN (6ES7515-2RM00-0AB0) Equipment Manual, 11/2019, A5E42009914-AB...