2-2. Adjustment
m
. In the adjustment using CameraAdjustmentTool.exe
(hereafter referred to as "adjustment tool"), if "OK" is
not displayed in the upper right area of the window, quit
the adjustment software and turn the power of this unit
off and on, and then perform the adjustment from the
beginning again.
When replacing the BI board and SY board, perform all
adjustments.
. In this section, the window of SNC-DM110 is used for
description unless otherwise stated.
2-2-1. Connection
1. Connect each equipment according to the connection
diagram in Section 2-1-3.
2. Turn on the power of each device.
3. Click "CameraAdjustmentTool.exe" to start the
camera adjustment software.
4. Type the IP address of camera, and then click the
[Connect] button.
n
If "Failed to connect" message is displayed on the
window, check if the network connection and IP
address are correct. After waiting for a while, click the
[Connect] button again.
n
If you want to start the adjustment over again after
clicking the [Connect] button, quit the adjustment
software once, and then turn the power of this unit off
and on again.
SNC-DS10/DM110
5. The dialog box is displayed. Then, select NTSC or
PAL radio button according to the measurement
device to be used.
6. Check that all check boxes are checked, and then click
the [OK] button.
In the case of SNC-DM110
In the case of SNC-DS10
n
The adjustment of item whose check box is checked can be
performed.
7. Check that the image is output on the video monitor.
n
If no image is output on the video monitor, press the
[VIDEO|OUT] button several times so that the image
can be output on the video monitor.
2-3