  • Page 1 Information and Communication Mobile Mobile Phones Level 2.5 Repair Documentation V 1.0 V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 2: Table Of Contents

    IRDA ..........................23 Camera Connector ......................26 10 Joystick Switch ........................29 11 Keyboard LEDs ......................... 32 12 MMI Connector ......................... 32 13 Display Connector ......................38 V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 3: Introduction

    Information and Communication Mobile Mobile Phones 1 Introduction SX1 product family, consists of 1 tripleband (GSM900, GSM1800 and GSM1900) handset Partnumber on IMEI label: SX1: S36880-S6500-#xxx , while # may be any letter (A-Z) and xxx may be any number from 100, 101, 102..
  • Page 4: O Connector (Slim Lumberg)

    - Problems with SW booting 2.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM-Tester 2.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 5 2.4.1.3. Repair by Software booting: Not possible! 2.4.1.4. Test: Retest handset after repair. 2.4.2. List of needed material: 2.4.2.1. Components: I/O Connector SX1 Placement: X2500 Part-Number: L36334-Z93-C303 2.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 6 2.4.2.3. Special tools: None 2.4.2.4. Working materials Desolder Wick / Braid Solder 2.4.3. Drawings Figure 1: SX1 board I/O connector Figure 2: SX1 I/O connector placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 7 Information and Communication Mobile Mobile Phones Table 1: SX1 Bottom Connector Pin Description Name IN/OUT Notes POWER POWER is needed for charging batteries and for supplying the accessories TX_1 USB/Serial interface RX_1 USB/Serial interface CTS_1 Data line for accessory bus...
  • Page 8: Battery Connector

    - Error message “WRONG BATTERY” on display. 3.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM-Tester. 3.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 9 3.4.1.3. Repair by Software booting: Not possible! 3.4.1.4. Test: Retest handset after repair. 3.4.2. List of needed material: 3.4.2.1. Components: Battery Connector SX1 Placement: X2181 Part-Number: L36334-Z97-C160 3.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 10 None 3.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 3.4.3. Drawings Figure 1: SX1 board Battery connector Figure 2: SX1 Battery connector placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 11: Speaker Connector

    Fault Symptoms for customers: - Speaker malfunction 4.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM-Tester. 4.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 12 4.4.2.3. Repair by Software booting: Not possible! 4.4.2.4. Test: Retest handset after repair. 4.4.3. List of needed material: 4.4.3.1. Components: Speaker connector SX1 Placement: X2100. X2101 Part-Number: L36334-Z97-C210 4.4.3.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 13 4.4.3.4. Working materials Desolder Wick / Braid Soldering Iron 4.4.4. Drawings Figure 1: SX1 board speaker connector side Figure 2: SX1 Speaker connector spring placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 14: Antenna Connector

    - No location update possible 5.2.2. Fault Symptoms on GSM Tester: Output power problems on the internal antenna No location update possible 5.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 15 Repair by Software booting: Not possible! 5.4.1.4. Test: Retest handset after repair. 5.4.2. List of needed material: 5.4.2.1. Components: Antenna Connector SX1 Placement: X870 Part-Number: L36334-Z93-C261 5.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 16 None 5.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 5.4.3. Drawings Figure 1: SX1 board Antenna connector Figure 2: SX1 Antenna connector placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 17: Card Reader

    - Handset does not accept SIM. 6.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM-Tester 6.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 18 Repair by Software booting: Not possible! 6.4.1.4. Test: Retest handset after repair. 6.4.2. List of needed material: 6.4.2.1. Components: Card Reader SX1 Placement: X2421 Part-Number: L36334-Z97-C298 6.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 19 6.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 6.4.3. Drawings Figure 1: SX1 board Card Reader site Figure 2: SX1 Card Reader placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 20: Mmi Connector

    - Display problems 7.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM Tester 7.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 21 Repair by Software booting: Not possible! 7.4.1.4. Test: Retest handset after repair. 7.4.2. List of needed material: 7.4.2.1. Components: Board connector SX1 Placement: X1000 Part-Number: L36334-Z97-C212 7.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 22 7.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 7.4.3. Drawings Figure 1: SX1 board MMI connector side Figure 2: SX1 MMI board connector placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 23: Irda

    - No infrared connection possible 8.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM Tester 8.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 24 8.4.1.4. Test: Retest handset after repair. 8.4.2. List of needed material: 8.4.2.1. Components: IRDA SX1 Placement: V2171 Part-Number: L36810-U6030-D670 8.4.2.2. Jigs and Tools: Hot Air Blower V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 25 Special tools: None 8.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 8.4.3. Drawings Figure 1: SX1 IRDA side Figure 2: SX1 IRDA placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 26: Camera Connector

    - Problems with camera function. 9.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM Tester 9.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 27 Repair by Software booting: Not possible! 9.4.1.4. Test: Retest handset after repair. 9.4.2. List of needed material: 9.4.2.1. Components: Camera board connector SX1 Placement: X2201 Part-Number: L36197-F5008-F341 9.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 28 9.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 9.4.3. Drawings Figure 1: SX1 board camera connector side Figure 2: SX1 camera connector placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 29: Joystick Switch

    - Problem with joystick function. 10.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM Tester 10.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 30 Retest handset after repair. 10.4.2. List of needed material: 10.4.2.1. Components: Joystick SX1 Placement: S1152 Part-Number: L36315-Z77-C218 10.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 31 Special tools: None 10.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 10.4.3. Drawings Figure 1: SX1 joystick side Figure 2: SX1 joystick placement (top view) V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 32: Keyboard Leds

    - Keyboard Illumination does not work 11.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM-Tester. 11.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 33 Resolder new diode afterwards. Repair by Software booting: Not possible! 11.4.1.4. Test: Retest handset after repair. 11.4.2. List of needed material: 11.4.2.1. Components: Keyboard LEDs SX1 Placement: V1200. V1201. V1202. V1203 Part-Number: L36840-L2082-D670 11.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0...
  • Page 34 Information and Communication Mobile Mobile Phones 11.4.2.3. Special tools: None 11.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 11.4.3. Drawings Figure 1: SX1 MMI board keyboard LEDs side V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 35: Mmi Connector

    - Display problems 12.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM Tester 12.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 36 Repair by Software booting: Not possible! 12.4.1.4. Test: Retest handset after repair. 12.4.2. List of needed material: 12.4.2.1. Components: Board connector SX1 Placement: X1100 Part-Number: L36334-Z97-C211 12.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 37 Information and Communication Mobile Mobile Phones 12.4.2.3. Special tools: None 12.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 12.4.3. Drawings Figure 1: SX1 board MMI connector side V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 38: Display Connector

    - Display problems 13.2.2. Fault Symptoms on GSM Tester: This fault cannot be detected with a GSM Tester 13.3. Priority: Mandatory Repair Optional Not Yet Defined V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...
  • Page 39 Repair by Software booting: Not possible! 13.4.1.4. Test: Retest handset after repair. 13.4.2. List of needed material: 13.4.2.1. Components: Display connector SX1 Placement: X1000 Part-Number: L36197-F5004-F505 13.4.2.2. Jigs and Tools: Hot Air Blower Soldering Iron V 1.0 ICM MP CCQ GRM...
  • Page 40 Information and Communication Mobile Mobile Phones 13.4.2.3. Special tools: None 13.4.2.4. Working materials Desolder Wick / Braid Soldering Iron 13.4.3. Drawings Figure 1: SX1 board display connector side V 1.0 ICM MP CCQ GRM Page Company Confidential 06/03 Copyright 2003© Siemens AG...