Digital I/O for On
Street Peripherals
Spur connector
RAG Node Status
LEDs
RAG
Node
Connectors
4.2.2
RAG Node Interfaces: Power and Comms (PL4)
The main physical interface to the RAG node is via the Bypass to Node ribbon cable. This cable can
only be connected one way.
Assuming an operational system, once the Bypass cable is pushed into place, the Node will be
provided with power and data.
Assuming correct configuration at the controller, the Node may begin operation immediately.
4.2.3
RAG Node Interfaces: LED signals
SK1 – 4 are used for the LED signal interfaces. For basic RAG installations;
RED is connected to SK4
Amber is connected to SK3
Green is connected to SK2 (also referred to as Green1)
If there is a requirement for a second filter (Second Green);
Extra Green must be connected to SK1 (also referred to as Green2).
ST950 Plus+ User Manual
Figure 38 : Bypass Module and RAG Node
Page 75 of 176
667/HE/53000/000
Bypass Module
Bypass to Node
cable
Connector
for
Regulatory Signs
Issue 2
Unrestricted