hit counter script
Siemens Acvatix GLB111.9E/MO Manual

Siemens Acvatix GLB111.9E/MO Manual

Rotary actuator for ball valves modbus rtu
Hide thumbs Also See for Acvatix GLB111.9E/MO:

Advertisement

Quick Links

s
Acvatix™
Rotary Actuator for Ball Valves Modbus RTU
GLB111.9E/MO
A6V10881143_en--_c
2019-04-25
Rotary actuator for ball valves 10 Nm with Modbus communication
GLB111.9E/MO
For air-handling units (AHU) and other heating / cooling applications
Modbus RTU communication
UL listed
For 2-port and 3-port control ball valves, internally threaded connections
(VAI61.. and VBI61..) or externally threaded connections (VAG61.. and
VBG61..), DN15 to DN50
For open/close ball valves 2-port and changeover ball valves 3-port, internally
threaded connections (VAI60.. and VBI60..) or externally threaded connections
(VAG60.. and VBG60..), DN15 to DN50
For 6-port control ball valve, externally threaded connections (VWG41..),
DN20
Operating voltage AC 24 V, 10 Nm
Siemens
Smart Infrastructure

Advertisement

Table of Contents
loading

Summary of Contents for Siemens Acvatix GLB111.9E/MO

  • Page 1 For open/close ball valves 2-port and changeover ball valves 3-port, internally threaded connections (VAI60.. and VBI60..) or externally threaded connections (VAG60.. and VBG60..), DN15 to DN50 ● For 6-port control ball valve, externally threaded connections (VWG41..), DN20 A6V10881143_en--_c Siemens 2019-04-25 Smart Infrastructure...
  • Page 2: Type Summary

    Please refer to data sheet N4698 for information on accessories and spare parts. Actuator rotates Ordering (Example) Product no. Stock no. Description Amount GLB111.9E/MO S55499-D206 Rotary actuator for Ball Valves with Modbus RTU communication 2 / 14 Siemens A6V10881143_en--_c Smart Infrastructure 2019-04-25...
  • Page 3: Equipment Combinations

    Equipment combinations The rotary actuators are suitable for operation of the following Siemens ball valves: VA..61.. 2-port and VB..61.. 3-port control ball valves Control ball valves with: GLB..9E internal threads external threads G..B ‒ ‒ VAG61.15.. G 1 B 1…6.3 ‒...
  • Page 4: Product Documentation

    (5/10 Nm), incl. Modbus types basics Mounting Instruction Rotary-type Mounting / installation instruction for A6V10920701 actuator GLB111.9E/MO Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download 4 / 14 Siemens A6V10881143_en--_c Smart Infrastructure 2019-04-25...
  • Page 5 3. If the button is pressed within these 3s, the reset is cancelled. 4. After those 3s à LED shines (reset), then green (start-up). Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download 5 / 14 A6V10881143_en--_c Siemens 2019-04-25 Smart Infrastructure...
  • Page 6 1. Enter addressing mode 2. Set 1-digits: Press button 5-times à LED flashes green per button press 3. Store address: press button until LED shines à address is stored and displayed 1x for confirmation 6 / 14 Siemens A6V10881143_en--_c Smart Infrastructure 2019-04-25...
  • Page 7: Modbus Registers

    0 = Ready / 1 = Load / 2 = Discard Status See below Device information 1281 Factory Index 1282-83 Factory Date Cf. product documentation CE1Z4634 1284-85 Factory SeqNo 1409-16 TypeASN [Char_16..1] The documents can be downloaded from http://siemens.com/bt/download 7 / 14 A6V10881143_en--_c Siemens 2019-04-25 Smart Infrastructure...
  • Page 8: Supported Function Codes

    Mounting ● Do not open the rotary actuators Mounting positions, cf. mounting instr. A6V10920701 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following internet address: http://siemens.com/bt/download 8 / 14 Siemens A6V10881143_en--_c Smart Infrastructure 2019-04-25...
  • Page 9 New value (ex.) MacAddress Baudrate 0 = auto 1 = 9600 Transmission Mode 0 = 1-8-E-1 3 = 1-8-N-2 Termination 0 = Off 0 = Off BusConfigCmd 0 = Ready 1 = Load 9 / 14 A6V10881143_en--_c Siemens 2019-04-25 Smart Infrastructure...
  • Page 10 Comply with all local and currently applicable laws and regulations. Warranty Technical data on specific applications are valid only together with Siemens products listed under "Equipment combinations". Siemens rejects any and all warranties in the event that third-party products are used.
  • Page 11: Technical Data

    120 Ω electronically switchable Termination Default: Off Degree of protection Degree of protection Degree of protection acc. to EN 60529 IP54 (see mounting instruction) Safety class Safety class acc. to EN 60730 11 / 14 A6V10881143_en--_c Siemens 2019-04-25 Smart Infrastructure...
  • Page 12 (RoHS compliance, materials composition, packaging, environmental benefit, disposal). Dimensions / Weight Weight Without packaging 0.6 kg Dimensions 71 x 158 x 61 mm The documents can be downloaded from http://siemens.com/bt/download 12 / 14 Siemens A6V10881143_en--_c Smart Infrastructure 2019-04-25...
  • Page 13 100 % of the time. Dimensions Dimensions in mm Minimum clearance from ceiling or wall for mounting, = > 100 mm uu = > 200 mm connection, operation, maintenance etc. 13 / 14 A6V10881143_en--_c Siemens 2019-04-25 Smart Infrastructure...
  • Page 14 Issued by © Siemens Switzerland Ltd, 2016 Technical specifications and availability subject to change without notice. Siemens Switzerland Ltd Smart Infrastructure Global Headquarters Theilerstrasse 1a 630 Zug Switzerland Tel. +41 58-724 24 24 www.siemens.com/buildingtechnologies Dokument-ID A6V10881143_en--_c Ausgabe 2019-04-25...