6.10

RESET for time relay K1T

There is a contactor K3A in the e-box (see E-plan attached). At a reactor temperature of> +
130 °C ... + 150 °C it is possible, in consultation with the service technician of
BEKO TECHNOLOGIES, to actuate the RESET key of the K3A and thus to bridge the time
relay.
When the RESET button is pressed, the incline seat valves V1 and V2 open. This can be
utilised to wait for e.g. shorten a short-term voltage drop.
R
RESET button for relay K1T
DANGER
Observe temperature
V01 / 11-043
At a reactor temperature of <+ 130 °C ... + 150 °C the time of K1T of
approx. 21 hours must be kept.
Only after reaching a reactor temperature> + 130 °C ... + 150 °C can
the possibility of the RESET key (R) on the relay K3A be used.
A reactor temperature > + 250 °C it is a fault and the system must be
shut down and checked.
The RESET button (R) must not be pressed in this case.
Commissioning of the BEKOKAT
and approval by authorised skilled technical personnel.
Installation and Operation Manual BEKOKAT
®
is only permitted after inspection
®
77 / 88