5.3 Ventilation
Ensure that there is an air exchange rate of at least 300 m
3
3
2,649 ft
(75 m
5.4 Optimal Elevation
Install the machine at an elevation below 3,280.8' (1,000 m) (898.7 hPa) for
optimal machine performance.
5.5 Lighting
Canon USA recommends installing the machine in a location with at least 500 lux
of lighting 29 1/2" (750 mm) above the floor for normal operations and
maintenance.
5.6 Sunlight
Avoid installing the machine in direct sunlight. Direct sunlight has adverse effects
on toner consistency and image quality. If direct sunlight is unavoidable, use
curtains to shade the machine. Make sure that the curtains do not block the
machine's ventilation slots or louvers, or interfere with the electrical cord or power
supply.
5.7 Ammonia
Avoid installing the machine where ammonia is emitted. In a sufficient amount,
ammonia will attack the surfaces of the machine's paper feed and image quality
components, thereby shortening their useful life and increasing the need for
periodic and remedial maintenance.
A professional assessment of the air quality in the room in which the machine is to
be installed is recommended prior to its installation.
Version 1
Océ VarioPrint 6000+ Series Customer Expectations Document
) of space in the location where the machine will be installed.
Océ VarioPrint 6000+ Customer Expectations Document
3
per hour, and at least