2
Converting SCSI Configuration from
Simplex to Duplex
Safety Information
Follow the procedures listed below to ensure safe handling of components and to prevent harm to both you
and the HP Server:
•
Use an antistatic wrist strap and a grounding mat, such as those included in the Electrically Conductive
Field Service Grounding Kit (HP 9300-1155).
•
Handle accessory boards and components by the edges only. Do not touch any metal-edge connectors or
any electrical components on accessory boards.
•
Do not wear clothing subject to static charge build-up, such as wool or synthetic materials.
WARNING
Hazardous voltages are present inside the HP Server. Always remove AC power
from the server and associated assemblies while working inside the unit. Serious
injury may result if this warning is not observed.
Service Tools Required
Service of this product may require one or more of the following tools:
•
Electrically Conductive Field Service Kit (P/N 9300-1155)
•
1/4 inch Flat Blade Screwdriver
•
ACX-15 Torx® Screwdriver
Accessing a Rack Mounted Server
The hp Integrity rx4640 server is designed to be rack mounted. The following procedure explains how to gain
access to an hp Integrity rx4640 server that is mounted in an approved rack. For rack installation
instructions, review the document titled hp Integrity rx4640 Server Rack Installation Guide.
WARNING
Ensure that all anti-tip features (front and rear anti-tip feet installed; adequate
ballast properly placed, etc.) are employed prior to extending the server.
Chapter 2
9