Description
3.6 Mounting and options
Releasing the brake
Procedure
• Press the manual release lever toward the NDE. The spring-loaded brake is mechanically
released.
You have deactivated the braking force.
Securing the manual brake release
In the unactuated state, the manual release lever must be in the vertical position, see the
diagram. Only in this position is the brake fully closed and the full braking effect ensured. The
manual release lever can only be removed in the vertical position.
Procedure
Figure 3-4
1. Place the manual release lever in the vertical position.
2. Remove the manual release lever.
You have secured the spring-loaded brake against unintended actuation.