hit counter script

Decommissioning The Machine; Re-Commissioning The Machine; Special Operating Conditions - Siemens SIMOTICS DC 1HQ7 Operating Instructions & Installation Instructions

Dc motor
Table of Contents

Advertisement

Operation

8.8 Special operating conditions

8.6

Decommissioning the machine

NOTICE
Damage as a result of an extended period out of service
If the machine is going to be out of service for longer than six months, then take the necessary
measures for preservation and storing. Otherwise damage to the machine will result.
Record the decommissioning steps. This log will be useful upon recommissioning.
See also
Transport and storage (Page 25)
8.7

Re-commissioning the machine

When you re-commission the machine, proceed as follows:
● Study the record made when the machine was decommissioned, and reverse the measures
● Perform the measures listed in the "Commissioning" section.
See also
Commissioning (Page 63)
8.8
Special operating conditions
Operating under light-load conditions
If a machine is operated continuously or over a long period under light-load conditions with
approximately half rated current or less, damage will occur. High brush wear or problems with
the commutator may result. More details are available in the chapter titled "Faults".
If the motor is to be operated continuously under light-load conditions, consult the
manufacturer.
Loading at standstill
Load stationary DC motors with armature current only for short periods so as to protect the
commutator against damage. Obtain the permissible current and time values for loading at
standstill from the manufacturer.
76
that were taken for conservation and storage.
SIMOTICS DC 1HQ7
Operating Instructions 02/2016