4. Empty the drain pump. Refer to the
emergency drain procedure.
5. When the drain pump is empty, install the
inlet hose again.
14. TROUBLESHOOTING
WARNING!
Refer to Safety chapters.
14.1 Alarm Codes and Potential failures
The appliance does not start or it stops during operation. First try to find a solution to the problem
(refer to the tables).
WARNING!
Deactivate the appliance before carrying out any check.
With some problems, the display shows an alarm code and the Start/
Pause
button may flash continuously:
Alarm Codes
The appliance does not fill with
water properly.
The appliance does not drain the
water.
The appliance lid is open or not
closed correctly.
Make sure that the temperature is higher
than 0 °C before you use the appliance
again.
The manufacturer is not responsible for
damages caused by low temperatures.
Possible solution
•
Make sure that the water tap is open.
•
Make sure that the pressure of the water supply is not too low. For this
information, contact your local water authority.
•
Make sure that the water tap is not clogged.
•
Make sure that the inlet hose has no kinks, damages or bends.
•
Make sure that the connection of the water inlet hose is correct.
•
Make sure that the filter of the inlet hose and the filter of the valve are not
clogged. Refer to 'Care and cleaning'.
•
Make sure that the sink spigot is not clogged.
•
Make sure that the drain hose has no kinks or bends.
•
Make sure that the drain filter is not clogged. Clean the filter, if necessa‐
ry. Refer to "Care and cleaning".
•
Make sure that the connection of the drain hose is correct.
•
Set the drain programme if you set a programme without drain phase.
•
Set the drain programme if you set an option which ends with water in
the tub.
•
Make sure that the lid is properly closed.
WARNING!
ENGLISH
29