QuickSpecs
Technical Specifications
System Unit
Tower Dimensions
(H x W x D)
(with feet/bezel)
Rack Dimensions
(H x W x D)
(with feet/bezel)
Tower Weight
(approximate)
Rack Weight
(approximate)
Input Requirements
(per power supply)
BTU Rating
Power Supply Output
(per power supply)
System Inlet
Temperature
DA - 14226 North America — Version 41 — December 9, 2013
HP ProLiant ML350p Generation 8 (Gen8)
18.19 x 8.58 x 29.13 in (46.2 x 21.8 x 74.0 cm)
8.58 x 19.0 x 28.83 in. (21.8 x 48.26 x 73.22cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
Rated Steady-State Power 460(750) W (at 100 VAC),
Maximum Peak Power
Operating
114.84 lb (52.09 kg)
70.33 lb (31.9 kg)
110.36 lb (50.06 kg)
60.91 lb (27.63 kg)
100 to 240 VAC
7.1 Amps (at 120VAC) to 3.5 Amps (at 240 VAC)
50 to 60 Hz
852 W
460W - 1773 BTU / hr (at 120 VAC), 1715 (at 240
VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at 240
VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600 (at 240
VAC)
460(750) W (at 200 VAC)
460(750) W (at 100 VAC),
460(750) W (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3048 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
Page 63