8.1.2.1 – SUMMARY TABLE OF ERROR CODES / ACTIONS
ERROR
BLOCK
CODE
0
BURNER
1
2
BURNER
3
BURNER
4
BURNER
5
BURNER
6
BURNER
7
BURNER
8
BURNER
9
SYSTEM
10
BURNER
11
SYSTEM
12
SYSTEM
BURNER
14
15
SYSTEM
16
SYSTEM
17
SYSTEM
SYSTEM
18
19
SYSTEM
20
SYSTEM
21
SYSTEM
22
SYSTEM
SYSTEM
23
24
SYSTEM
SOI 04.05 FV
SUMMARY TABLE ERROR CODE / ACTION
--
--
1 Verify the presence of sparks.
2 Verify the presence of gas.
3 Verify the sparks.
4 Verify the position of the burner cap and that the flame warms up the
thermocouple.
5 Verify the thermocouple connections.
6 Verify the main electric valve.
7 Verify the burner electric valve.
8 Replace the power board.
1 Verify board connections / electric valve of relative burner.
2 Replace the power board.
1 Verify board connections / electric valve of relative burner.
2 Replace the power board.
1 Verify board connections / electric valve of relative burner.
2 Replace the power board
1 Verify board connections / electric valve of relative burner.
2 Replace the power board
1 Verify board connections / electric valve of relative burner.
2 Replace the power board
1 Verify board connections / electric valve of relative burner.
2 Replace the power board
1 Replace the power board.
1 Wait cooling down.
2 Replace the power board.
1 Unlock the burner.
1 Replace the power board.
1 Replace the power board.
1 Verify the thermocouple connections.
2 Replace the thermocouple.
3 Replace the power board.
1 Replace the power board.
1 Replace the power board.
1 Replace the power board.
1 Replace the power board.
1 Replace the power board.
1 Replace the power board.
1 Replace the power board.
1 Replace the power board.
1 Replace the power board.
1 Replace the power board.
ACTION
41/57
599 36 62-62