41. Color Reproduction Check (Indoor SD: ND 2)
RadarW
RadarW
RadarW
RadarW
RadarW
Subject
Measurement Point
Measuring Instrument
Specified Value
Note 1: Perform "Color Reproduction Adjustment" before this
adjustment.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, select page: 6, address: 01, set data: 00, and press
PAUSE (Write) button.
Switch setting
1) POWER ......................................................... CAMERA mode
2) ND FILTER ............................................................................ 2
3) D. EXTENDER (Menu setting) ...................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) REC FORMAT (Menu setting) ......................................... DV
HVR-V1J/V1U/V1N/V1E/V1P/V1C
Color bar chart (Color reproduction
adjustment frame)
Video terminal of Adjusting remote
A/V jack
commander
(75 Ω terminated)
Vectorscope
All color
Data of page: 6
luminance
address: 0C is
points should
"00"
settle within each
color
reproduction
frame.
Checking method:
Order Page Address Data
1
0
01
2
0
10
E
3
8C
(AE)
4
0
10
5
6
15
6
6
C9
7
6
CA
8
6
D0
9
6
01
10
6
02
11
6
0C
12
13
Processing after Completing Adjustment:
Order Page Address Data
1
6
01
2
6
CA
3
6
C9
4
6
15
5
0
10
E
6
8C
(AE)
7
0
10
8
0
01
6-67
Procedure
01
0A
01
Press PAUSE (Write) button.
00
86
10
04
47
4D
Press PAUSE (Write) button.
Check the data changes to
"01".
Check the data is "00".
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst lumi-
nance point to the burst
position of color reproduc-
tion frame.
Check that the each color
luminance point is in each
color reproduction frame.
Procedure
00
Press PAUSE (Write) button.
00
00
00
0A
00
Press PAUSE (Write) button.
00
00