Table of Contents
Table of Contents
10
Chapter 1 Overview
16
Overview
18
Inspection of the Purchased Product
18
Inspecting the Product
18
Instruction Manual (this Manual)
18
Method of Inquiry and Product Warranty
19
Method of Inquiry
19
Product Warranty
19
Exterior Views and Names of Parts
20
Chapter 2 Installation and Wiring
21
Installation
23
Precautions for Installation
24
Operation
24
Backing Plate
26
Wiring
27
Terminal Connection Diagram and Explanation of Terminals and Switch Settings
28
Wiring of the Main Circuit
36
Wiring of the Control Circuit
44
Wiring of the Digital Operator
45
Selection and Wiring of Regenerative Braking Resistor (on 5.5 Kw to 22 Kw Models)
46
Chapter 3 Operation
47
Operating Methods
49
How to Operate the Digital Operator
52
Names and Functions of Components
52
Code Display System and Key Operations
53
How to Make a Test Run
59
Chapter 4 Explanation of Functions
62
Monitor Mode
64
Output Frequency Monitoring (D001)
64
Output Current Monitoring (D002)
64
Rotation Direction Minitoring (D003)
64
Process Variable (PV), PID Feedback Monitoring (D004, A071, A075)
64
Intelligent Input Terminal Status (D005)
65
Intelligent Output Terminal Status (D006)
65
Scaled Output Frequency Monitoring (D007, B086)
65
Torque Command Monitoring (D009, P033, P034)
66
Torque Bias Monitoring (D010, P036 to P038)
66
Torque Monitoring (D012)
66
Output Voltage Monitoring (D013)
66
Power Monitoring (D014)
66
Cumulative Power Monitoring (D015, B078, B079)
67
Cumulative Operation RUN Time Monitoring (D016)
67
Cumulative Power-On Time Monitoring (D017)
67
Heat Sink Temperature Monitoring (D018)
67
Motor Temperature Monitoring (D019, B98)
67
Life-Check Monitoring (D022)
68
Program Counter Display (Easy Sequence Function) (D023)
68
Program Number Monitoring (Easy Sequence Function) (D024)
68
User Monitors 0 to 2 (Easy Sequence Function)
68
Pulse Counter Monitor
68
Position Command Monitor (in Absolute Position Control Mode)
68
Current Position Monitor (in Absolute Position Control Mode)
68
Trip Counter (D080)
68
Programming Error Monitoring (D090)
69
DC Voltage Monitoring (D102)
69
BRD Load Factor Monitoring (D103, B090)
69
Electronic Thermal Overload Monitoring (D104)
69
Error Codes
69
Function Mode
70
Output Frequency Setting (F001, A001, A020, C001 to C008)
70
Keypad Run Key Routing (F004)
70
Rotational Direction Restriction (B035)
70
Frequency Source Setting (A001)
70
Run Command Source Setting (A002, C001 to C008, C019, F004)
71
Stop Mode Selection (B091, F003, B003, B007, B088)
72
STOP Key Enable (B087)
72
Acceleration/Deceleration Time Setting (F002, F003, A004, P031, C001 to C008)
73
Base Frequency Setting (A003, A081, A082)
74
Maximum Frequency Setting (A004)
74
External Analog Input Setting (O, O2, and OI) (A005, A006, C001 to C008)
75
Frequency Addition Function (A145, A046, C001 to C008)
77
Start/End Frequency Setting for External Analog Input
77
External Analog Input (O/OI/O2) Filter Setting (A016)
78
V/F Gain Setting (A045, A082)
78
V/F Characteristic Curve Selection (A044, B100, B101)
79
Torque Boost Setting (A041, A042, A043, H003, H004)
81
Frequency Upper Limit Setting (A061, A062)
87
Jump Frequency Function (A063 to A068)
88
Acceleration Stop Frequency Setting (A069, A070, A097)
88
PID Function
89
C044)
89
Acceleration/Deceleration Curve Selection (A097, A098, A131, A132)
94
Energy-Saver Operation (A085, A086)
95
Retry or Trip after Instantaneous Power Failure
96
Phase Loss Power Input Protection (B006)
99
Electronic Thermal Protection (B012, B013, B015, B016, C021 to C026, C061)
100
Overload Restriction/Overload Notice
102
Overcurrent Restraint (B027)
103
Start Frequency Setting (B082)
105
Reduced Voltage Start Function (B036, B082)
105
Cooling-Fan Operation Setting (B092)
108
Intelligent Input Terminal Setting (SET, SET3) (C001 to C008)
109
Multispeed Select Setting (CF1 to CF4 and SF1 to SF7)
110
C001 Toc008)
113
2Nd/3Rd Motor Control Function (SET and SET3)
113
C001 to C008
114
Remote Control Function (up and DWN) (C101, C001 to C008)
119
3-Wire Interface Operation Function (STA, STP, and F/R) (C001 to C008)
120
Control Gain Switching Function (CAS)
121
Analog Command Holding Function (AHD) (C001 to C008)
122
Intelligent Pulse Counter (PCNT and PCC)
122
Intelligent Output Terminal Setting (C021 to C026)
123
Running Signal (RUN) (C021 to C025)
123
Over-Torque Signal (OTQ) (A044, C021 to C025, C055 to C058)
123
Alarm Code Output Function (AC0 to AC3) (C021 to C025, C062)
128
Logical Output Signal Operation Function (LOG1 to LOG6)
129
Cooling-Fan Speed Drop Signal (WAF) (C021 to C026, B092 to D022)
131
Starting Contact Signal (FR) (C021 to C026)
131
Heat Sink Overheat Warning Signal (OHF) (C021 to C026, C064)
131
Low-Current Indication (LOC) Signal (C021 to C026, C038, C039)
132
Inverter Ready Signal (IRDY) (C021 to C026)
132
Forward Rotation Signal (FWR) (C021 to C026)
132
Reverse Rotation Signal (RVR) (C021 to C026)
133
Major Failure Signal (MJA) (C021 to C026)
133
Window Comparators (WCO/WCOI/WCO2)
134
Odc/Oidc/O2Dc)
134
Output Signal Delay/Hold Function (C130 to C141)
135
Input Terminal Response Time
135
External Thermistor Function (TH) (B098, B099, C085)
135
FM Terminal (C027, B081)
136
AM and AMI Terminals (C028, C029, C106, C108 to C110)
137
Initialization Setting (B084, B085)
138
Initial-Screen Selection
141
Power-On) (B038)
141
Automatic User-Parameter Setting (B039, U001 to U012)
142
Stabilization Constant Setting (H006)
142
Selection of Operation at Option Board Error (P001, P002)
142
Brake Control Function (B120 to B127, C001 to C008, C021, C025)
144
Deceleration and Stopping at Power Failure
146
Online Auto-Tuning Function
150
Secondary Resistance Compensation (Temperature Compensation) Function
150
Motor Constants Selection
151
Sensorless Vector Control
153
Sensorless Vector, 0 Hz Domain Control
154
Torque Monitoring Function (A044, C027 to C029, H003, H004)
155
Torque Limitation Function (A044, B040 to B044, C001 to C008, C021 to C025)
156
Reverse Run Protection Function (A044, B046)
157
Torque LAD Stop Function (A044, B040 to B045)
158
High-Torque Multi-Motor Operation
158
Easy Sequence Function (A017, P100 to P131)
159
Functions Available When the Feedback Option Board (SJ-FB) Is Mounted
160
Functions Requiring the SJ-FB
160
V2 Control Pulse Setting
160
Vector Control with Encoder Feedback
162
Torque Biasing Function
163
Torque Control Function
163
Pulse Train Position Control Mode
164
Electronic Gear Function
166
Motor Gear Ratio Setting Function
168
Position Biasing Function
168
Speed Biasing Function
168
Home Search Function
169
Absolute Position Control Mode
171
Operation in Absolute Position Control Mode
172
Multistage Position Switching Function (CP1/CP2/CP3)
174
Speed/Position Switching Function (SPD)
174
Zero-Return Function
175
Forward/Reverse Drive Stop Function (Fot/Rot)
176
Position Range Specification Function
176
Teaching Function
176
Servo-On Function
177
Pulse Train Frequency Input
178
Communication Functions
179
Communication in ASCII Mode
182
Communication in Modbus-RTU Mode
195
Chapter 5 Error Codes
231
Error Codes and Troubleshooting
233
Error Codes
233
Option Boards Error Codes
237
Trip Conditions Monitoring
241
Warning Codes
242
Chapter 6 Maintenance and Inspection
243
Precautions for Maintenance and Inspection
245
Daily Inspection
245
Cleaning
245
Periodic Inspection
245
Daily and Periodic Inspections
246
Ground Resistance Test with a Megger
247
Withstand Voltage Test
247
Method of Checking the Inverter and Converter Circuits
248
DC-Bus Capacitor Life Curve
249
Output of Life Warning
249
Methods of Measuring the Input/Output Voltages, Current, and Power
250
Chapter 7 Specifications
251
Specifications
251
External Dimensions
256
Chapter 8 List of Data Settings
259
Precautions for Data Setting
261
Monitoring Mode
261
Function Mode
262
Extended Function Mode
263
Advertisement
Advertisement
Related Products
Hitachi SJ700-110LFU2
Hitachi SJ700-110HFU2/E
Hitachi SJ700-1100HFU2/E
Hitachi SJ700-110LFF2
Hitachi SJ700-110LFUF2
Hitachi SJ700-110HFEF2
Hitachi SJ700-110HFUF2
Hitachi SJ700-185LFU2
Hitachi SJ700-150HFF2
Hitachi SJ700-150HFEF2
Hitachi Categories
Projector
Air Conditioner
Drill
Power Tool
TV
More Hitachi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual