Sign In
Upload
Manuals
Brands
Siemens Manuals
Relays
Argus 7SR12
Siemens Argus 7SR12 Manuals
Manuals and User Guides for Siemens Argus 7SR12. We have
3
Siemens Argus 7SR12 manuals available for free PDF download: Manual
Siemens Argus 7SR12 Manual (406 pages)
Overcurrent Relay Energy Management
Brand:
Siemens
| Category:
Protection Device
| Size: 4.73 MB
Table of Contents
Table of Contents
7
Description of Operation
5
Section 1: Introduction
12
Table 1-1 7SR11 Ordering Options
13
Figure 1-1 Functional Diagram of 7SR1101-1_A12-_CA0 Relay
15
Figure 1-2 Functional Diagram of 7SR1101-3_A12-_CA0 Relay
15
Figure 1-3 Functional Diagram of 7SR1103-1_A
15
Figure 1-4 Functional Diagram of 7SR1103-3_A
16
Figure 1-5 Connections Diagram for 7SR11 Relay
17
Table 1-2 7SR12 Ordering Options
18
Figure 1-6 Functional Diagram of 7SR1204-2_A12-_CA0 Relay
19
Figure 1-7 Functional Diagram of 7SR1204-4_A12-_CA0 Relay
19
Figure 1-8 Functional Diagram of 7SR1205-2_A
19
Figure 1-9 Functional Diagram of 7SR1205-4_A
20
Figure 1-10 Connections Diagram for 7SR12 Relay
21
Section 2: Hardware Description
22
General
22
Table 2-1 Summary of 7SR1 Relay Configurations
22
Case
23
Figure 2-1 E4 Relay Shown Withdrawn
23
Front Cover
24
Figure 2-2 Rear View of Relay (E6 Case with Optional IEC61850 Module)
24
Figure 2-3 Earth Connection Symbol
24
Figure 2-4 Relay with Standard Transparent Cover (E6 Case with Optional IEC61850 Module)
24
Power Supply Unit (PSU)
25
Figure 2-5 Relay with Transparent Cover and Push Buttons
25
Table 2-2 Power Supply Unit (PSU) Options
25
Operator Interface/ Fascia
26
Figure 2-6 Relay with Transparent Cover Removed (E6 Case with Optional IEC61850 Module)
26
Figure 2-7 Close up of Relay Label
26
Figure 2-8 Close up of Relay Identifier
27
Current Inputs
29
Voltage Inputs
29
Binary Inputs
29
Figure 2-9 LED Indication Label
29
Binary Outputs (Output Relays)
30
Figure 2-10 Binary Input Logic
30
Virtual Input/Outputs
31
Figure 2-11 Binary Output Logic
31
Self Monitoring
32
Figure 2-12 Start-Up Counter Meter
32
Figure 2-13 Unexpected Restarts Lockout Text
32
Figure 2-14 Start-Up Events
33
Protection Healthy/Defective
34
Section 3: Protection Functions
35
Current Protection: Phase Overcurrent (67, 51, 50)
35
Directional Control of Overcurrent Protection (67) - 7SR12
35
Figure 3-1 Logic Diagram: Directional Overcurrent Element (67)
36
Time Delayed Overcurrent Protection (51)
37
Figure 3-2 Logic Diagram: Instantaneous Over-Current Element
37
Applications Guide
37
Figure 3-3 Logic Diagram: Time Delayed Overcurrent Element
38
Siemens Protection Devices Limited
38
Current Protection: Voltage Controlled Overcurrent (51V) - 7SR12
39
Figure 3-4 Logic Diagram: Voltage Controlled Overcurrent Protection
39
Current Protection: Derived Earth Fault (67N, 51N, 50N)
40
Figure 3-5 Logic Diagram: Derived Directional Earth Fault Element
40
Time Delayed Derived Earth Fault Protection (51N)
41
Figure 3-6 Logic Diagram: Derived Instantaneous Earth Fault Element
41
Figure 3-7 Logic Diagram: Derived Time Delayed Earth Fault Protection
42
Current Protection: Measured Earth Fault (67G, 51G, 50G)
43
Figure 3-8 Logic Diagram: Measured Directional Earth Fault Protection
43
Figure 3-9 Logic Diagram: Measured Instantaneous Earth-Fault Element
44
Time Delayed Measured Earth Fault Protection (51G)
45
Figure 3-10 Logic Diagram: Measured Time Delayed Earth Fault Element (51G)
45
Current Protection: Sensitive Earth Fault (67SEF, 51SEF, 50SEF)
46
Directional Control of Sensitive Earth Fault Protection (67SEF) - 7SR12
46
Instantaneous Sensitive Earth Fault Protection (50SEF)
47
Figure 3-11 Logic Diagram: SEF Directional Element (67SEF)
47
Figure 3-12 Logic Diagram: 7SR11 SEF Instantaneous Element
47
Figure 3-13 Logic Diagram: 7SR12 SEF Instantaneous Element
48
Time Delayed Sensitive Earth Fault Protection (51SEF)
49
Figure 3-14 Logic Diagram: 7SR11 SEF Time Delayed Element (51SEF)
49
Figure 3-15 Logic Diagram: 7SR12 SEF Time Delayed Element (51SEF)
50
Current Protection: High Impedance Restricted Earth Fault - (64H)
51
Current Protection: Cold Load (51C)
51
Figure 3-16 Logic Diagram: High Impedance REF (64H)
51
Current Protection: Negative Phase Sequence Overcurrent - (46NPS)
52
Figure 3-17 Logic Diagram: Cold Load Settings (51C)
52
Current Protection: Under-Current (37)
53
Figure 3-18 Logic Diagram: Negative Phase Sequence Overcurrent (46NPS)
53
Current Protection: Thermal Overload (49)
54
Figure 3-19 Logic Diagram: Phase Current Inputs Undercurrent Detector (37)
54
Figure 3-20 Logic Diagram: Earth Current Inputs Undercurrent Detector (37G)
54
Figure 3-21 Logic Diagram: Sensitive Earth Current Inputs Undercurrent Detector (37SEF)
54
Current Protection: Line Check 50LC, 50G LC and 50SEF LC - Only Software Option 'C
55
Figure 3-22 Logic Diagram: Thermal Overload Protection (49)
55
Figure 3-23 Logic Diagram: 50G Line Check Elements (50G LC)
56
Figure 3-24 Logic Diagram: 50SEF Line Check Elements (50SEF LC)
56
Figure 3-25 Logic Diagram: 50 Line Check Elements (50LC)
56
Current Protection: Arc Flash Detector (50 AFD)
57
Figure 3-26 Logic Diagram: Arc Flash Detector (50 AFD)
57
Voltage Protection: Phase Under/Over Voltage (27/59) - 7SR12
58
Figure 3-27 Logic Diagram: Under/Over Voltage Elements (27/59)
58
Voltage Protection: Negative Phase Sequence Overvoltage (47) - 7SR12
59
Voltage Protection: Neutral Overvoltage (59N) - 7SR12
59
Figure 3-28 Logic Diagram: NPS Overvoltage Protection (47)
59
Figure 3-29 Logic Diagram: Neutral Overvoltage Element (59N)
60
Voltage Protection: Under/Over Frequency (81) - 7SR12
61
Figure 3-30 Logic Diagram: Under/Over Frequency Detector (81)
61
Power Protection: Power (32) - 7SR12
62
Figure 3-31 Logic Diagram: Power Protection (32)
62
Power Protection: Sensitive Power (32S) - 7SR12
63
Figure 3-32 Logic Diagram: Sensitive Power Protection (32S)
63
Power Protection: Power Factor (55) - 7SR12
64
Figure 3-33 Logic Diagram: Power Factor Protection (55)
64
Section 4: Control & Logic Functions
65
Auto-Reclose (79) Optional Function
65
Overview
65
Auto Reclose Sequences
66
Autoreclose Prot'n Menu
67
Autoreclose Config Menu
67
Figure 4-1 Typical AR Sequence with 3 Inst and 1 Delayed Trip
67
P/F Shots Sub-Menu
69
E/F Shots Sub-Menu
69
SEF Shots Sub-Menu
69
Extern Shots Sub-Menu
70
Figure 4-2 Basic Auto-Reclose Sequence Diagram
71
Manual CB Control
72
Circuit Breaker
73
Figure 4-3 Logic Diagram: Circuit Breaker Status
74
Quick Logic
75
Figure 4-4 Sequence Diagram: Quick Logic PU/DO Timers (Counter Reset Mode Off)
76
Section 5: Supervision Functions
77
Circuit Breaker Failure (50BF)
77
Figure 5-1 Logic Diagram: Circuit Breaker Fail Protection (50BF)
77
VT Supervision (60VTS) - 7SR1205 & 7SR1206
78
Figure 5-2 Logic Diagram: VT Supervision Function (60VTS)
79
CT Supervision (60CTS)
80
60CTS for 7SR12
80
Figure 5-3 Logic Diagram: CT Supervision Function (60CTS) - 7SR11
80
Broken Conductor (46BC)
81
Figure 5-4 Logic Diagram: CT Supervision Function (60CTS) - 7SR12
81
Figure 5-5 Logic Diagram: Broken Conductor Function (46BC)
81
Trip/ Close Circuit Supervision (74TCS & 74CCS)
82
Figure 5-6 Logic Diagram: Trip Circuit Supervision Feature (74TCS)
82
Figure 5-7 Logic Diagram: Close Circuit Supervision Feature (74CCS)
82
2Nd Harmonic Block/Inrush Restraint (81HBL2) Phase Elements Only
83
Figure 5-8 Functional Diagram for Harmonic Block Feature (81HBL2)
83
Section 6: Other Features
84
Data Communications
84
IEC 61850 Communications
84
Maintenance
84
Output Matrix Test
84
CB Counters
85
I 2 Tcb Wear
85
General Pickup
85
Data Storage
85
General
85
Demand
85
Event Records
86
Waveform Records
86
Fault Records
86
Energy Storage - 7SR12
87
Figure 6-1 Energy Direction Convention
87
Disk Activity Warning
88
Metering
88
Operating Mode
89
Control Mode
89
Table 6-1 Operating Mode
89
Real Time Clock
90
Time Synchronisation - Data Communication Interface
90
Time Synchronisation - Binary Input
90
Settings Groups
90
Password Feature
91
The Copyright and Other Intellectual Property Rights in this Document, and in any Model or Article Produced from It (and Including
93
Section 1: Introduction/Section 2: Setting & Configuring the Relay Using Reydisp Evolution
95
Section 1: Introduction
96
Relay Menus and Display
96
Operation Guide
98
User Interface Operation
98
Setting Mode
100
Instruments Mode
101
Fault Data Mode
107
Section 2: Setting & Configuring the Relay Using Reydisp Evolution
108
Physical Connection
108
Front USB Connection
108
Rear RS485 Connection
108
Optional Rear EN100 Ethernet Module (COM3)
109
Configuring Relay Serial Data Communication
110
Connecting to the Relay for Setting Via Reydisp
111
Configuring the User Texts Using Reydisp Language Editor
112
The Copyright and Other Intellectual Property Rights in this Document, and in any Model or Article Produced from It (and Including
113
Section 1: Common Functions/Section 2: Protection Functions
115
Section 1: Common Functions
118
General
118
CE Conformity
118
Reference
118
Dimensions
118
Weights
119
Energising Quantities
120
Auxiliary Power Supply
120
AC Analogue Current
122
AC Analogue Voltage
122
Binary (Digital) Outputs
123
Binary (Digital) Inputs
123
Functional Performance
124
Instrumentation
124
Real Time Clock
124
Data Communication Interfaces
125
USB 2.0 Data Communication Interface
125
RS485 Data Communication Interface
125
Fibre Optic Ethernet Data Communication Interface (IEC 61850 Option)
125
Electrical Ethernet Data Communication Interface (IEC 61850 Option)
125
Environmental Performance
126
General
126
Emissions
127
Immunity
127
Mechanical
129
Section 2: Protection Functions
130
27/59 Under/Over Voltage
130
Reference
130
Operate and Reset Level
130
Operate and Reset Time
130
Power
131
Reference
131
Operate and Reset Level
131
Operate and Reset Time
131
Operate Threshold
131
Sensitive Power
132
Reference
132
Operate and Reset Level
132
Operate and Reset Time
132
Operate Threshold
132
Undercurrent
133
Reference
133
Operate and Reset Level
133
Operate and Reset Time
133
Negative Phase Sequence Overcurrent
134
Reference (46DT)
134
Operate and Reset Level (46DT)
134
Operate and Reset Time (46DT)
134
Reference (46IT)
134
Operate and Reset Level (46IT)
134
Operate and Reset Time (46IT)
135
Negative Phase Sequence Voltage
136
Reference (47)
136
Operate and Reset Level (47)
136
Operate and Reset Time (47)
136
Thermal Overload
137
Reference
137
Operate and Reset Level
137
Operate and Reset Time
137
Instantaneous Overcurrent
139
Reference
139
Operate and Reset Level
139
Operate and Reset Time
139
Instantaneous Measured Earth Fault
140
Reference
140
Operate and Reset Level
140
Operate and Reset Time
140
Instantaneous Derived Earth Fault
141
Reference
141
Operate and Reset Level
141
Operate and Reset Time
141
50SEF Instantaneous Sensitive Earth Fault
142
Reference
142
Operate and Reset Level
142
Operate and Reset Time
142
Time Delayed Overcurrent
143
Reference
143
Operate and Reset Level
143
Operate and Reset Time
143
Time Delayed Measured Earth Fault
149
Reference
149
Operate and Reset Level
149
Operate and Reset Time
149
Time Delayed Derived Earth Fault
151
Reference
151
Operate and Reset Level
151
Operate and Reset Time
151
51SEF Time Delayed Sensitive Earth Fault
153
Reference
153
Operate and Reset Level
153
Operate and Reset Time
153
Voltage Controlled Overcurrent
155
Reference
155
Operate and Reset Level
155
50AFD ARC Flash Detector
156
Reference
156
Operate and Reset Level
156
Operate and Reset Time
156
Power Factor
157
Reference
157
Operate and Reset Level
157
Operate and Reset Time
157
Operate Threshold
157
Neutral Voltage Displacement
158
Reference (59NDT)
158
Operate and Reset Level (59NDT)
158
Operate and Reset Time (59NDT)
158
Reference (59NIT)
158
Operate and Reset Level (59NIT)
158
Restricted Earth Fault Protection
160
Reference
160
Operate and Reset Level
160
Operate and Reset Time
160
67/67N Directional Overcurrent & Earth Fault
161
Reference
161
Operate Angle
161
Operate Threshold
161
Operate and Reset Time
161
Directional SEF - Wattmetric
162
Reference
162
Operate and Reset Level
162
Operate and Reset Time
162
Under/Over Frequency
163
Reference
163
Operate and Reset Level
163
Operate and Reset Time
163
Section 3: Supervision Functions
164
46BC Broken Conductor
164
Reference
164
Operate and Reset Level
164
Operate and Reset Time
164
50BF Circuit Breaker Fail
165
Reference
165
Operate and Reset Level
165
Operate and Reset Time
165
60CTS & 60CTS-I Current Transformer Supervision
166
Reference
166
Current & Voltage Threshold
166
Operate and Reset Time
166
60VTS Voltage Transformer Supervision
167
Reference
167
Operate and Reset Level
167
Operate and Reset Time
167
74TCS & 74CCS Trip & Close Circuit Supervision
168
Reference
168
Operate and Reset Time
168
81HBL2 Inrush Detector
168
The Copyright and Other Intellectual Property Rights in this Document, and in any Model or Article Produced from It (and Including
169
Table of Contents
171
Introduction
173
Chapter 4 - 7SR120 · Data Communications Definitions
175
Introduction
175
Physical Connection
175
RS485 Interface (COM1)
176
USB Interface (COM2)
176
IEC 60870-5-103 Definitions
179
Introduction
179
Cause of Transmission
180
Application Service Data Unit (ASDU) Type
181
Point List
182
Event Function (FUN) & Information (INF) Numbers
182
Measurands
195
Disturbance Recorder Actual Channel (ACC) Numbers
195
MODBUS Definitions
197
Introduction
197
MODBUS Register Data Types
198
Float_Ieee_754
198
Fp_32Bits_3Dp
199
Uint32
199
Uint16
199
Event
200
Eventcount
201
Str32 & Str64
201
Bitstring
201
Point List
203
Coils (Read Write Binary Values)
203
Inputs (Read Only Binary Values)
204
Input Registers (Read Only Registers)
208
Holding Registers (Read Write Registers)
211
DNP3 Definitions
215
Device Profile
215
Implementation Table
218
Point List
224
Binary Input Points
224
Counters
236
Analog Inputs
236
Additional Settings
240
Not Applicable
241
IEC61850 Protocol Support
243
Introduction
243
Serial Modems
245
Introduction
245
Connecting a Modem to the Relay(S)
245
Setting the Remote Modem
245
Connecting to the Remote Modem
245
Configuration
247
Glossary
249
The Copyright and Other Intellectual Property Rights in this Document, and in any Model or Article Produced from It (and Including
253
Table of Contents
255
Section 1: Installation
257
Packaging
257
Unpacking, Storage and Handling
257
Recommended Mounting Position
257
Wiring
257
Earthing
258
Ancillary Equipment
258
Disposal
258
Section 2: Equipment Operating Conditions
259
Current Transformer Circuits
259
External Resistors
259
Front Cover
259
Section 3: Dimensions and Panel Fixings
260
Relay Dimensions and Weight
260
Fixings
262
Crimps
262
Panel Fixings
262
Section 4: Rear Terminal Drawings
263
Case
263
Section 5: Connection/Wiring/Diagrams
265
Wiring Diagram: 7SR1101 EF Relay with 3BI & 5BO
265
Wiring Diagram: 7SR1102 OC/EF Relay with 3BI & 5BO
266
Wiring Diagram: 7SR1103 OC/EF Relay with 6 BI & 8BO
267
Wiring Diagram: 7SR1107 OC/EF Relay with 4 BI & 8BO
268
Wiring Diagram: 7SR1204 Directional EF Relay with 3BI & 5BO
269
Wiring Diagram: 7SR1205 Directional OC/EF Relay with 3BI & 5BO
270
Wiring Diagram: 7SR1206 Directional OC/EF Relay with 6BI & 8BO
271
Wiring Diagram: 7SR1208 Directional OC/EF Relay with 4BI & 8BO
272
Current Transformer Configurations
273
Voltage Transformer Configurations
279
Section 6: Data Comms Connections
280
RS485 Connection
280
Additional (Optional) Ethernet Connection for IEC 61850
281
Ethernet Network Redundancy IEC 61850
282
RSTP - Rapid Spanning Tree Protocol
282
PRP - Parallel Redundancy Protocol
283
HSR - High Availability Seamless Redundancy Protocol
284
The Copyright and Other Intellectual Property Rights in this Document, and in any Model or Article Produced from It (and Including
285
Table of Contents
287
Section 1: Common Functions
290
Overview
290
Before Testing
290
Safety
290
Sequence of Tests
290
Test Equipment
291
Use of PC to Facilitate Testing
291
Precautions
291
Applying Settings
291
Tests
292
Inspection
292
Secondary Injection Tests
292
Primary Injection Tests
292
Putting into Service
292
AC Analogue Energising Quantities
293
Binary Inputs
293
Binary Outputs
294
Relay Case Shorting Contacts
294
Section 2: Protection Functions
295
Phase Directional Polarity Check
296
Out of 3 Logic
297
Phase Overcurrent (67/50,67/51)
298
Definite Time Overcurrent (50)
298
Inverse Time Overcurrent (51)
299
Voltage Controlled Overcurrent (51V)
301
Cold Load (51C)
303
Inverse Time Overcurrent (51C)
304
Arc Flash Detection (50AFD)
307
Directional Earth Fault Polarity Check (67N)
308
Derived Earth Fault (67/50N, 67/51N)
309
Directional Polarity
310
Definite Time Overcurrent (50N)
310
Inverse Time Overcurrent (51N)
310
Measured Earth Fault (67/50G,67/51G)
313
Directional Polarity
314
Definite Time Overcurrent (67/50G)
314
Inverse Time Overcurrent (67/51G)
314
Sensitive Earth Fault (67/50S,67/51S)
317
Directional Polarity
317
(50Sef)
318
Wattmetric Protection
318
Inverse Time Overcurrent (51SEF)
319
Restricted Earth Fault (64H)
321
Negative Phase Sequence Overcurrent (46NPS)
323
Definite Time NPS Overcurrent (46DT)
324
Inverse Time NPS Overcurrent (46IT)
324
Undercurrent (37)
326
Thermal Overload (49)
328
Over/Under Voltage
330
Phase Under/Over Voltage (27/59)
330
Undervoltage Guard (27/59UVG)
332
NPS Overvoltage (47)
332
Undervoltage Guard (47 U/V Guard)
333
Neutral Overvoltage (59N)
334
Definite Time (59NDT)
334
Inverse Time (59NIT)
334
Under/Over Frequency (81)
336
Power (32)
338
Sensitive Power (32S)
340
Power Factor (55)
342
Section 3: Supervision Functions
344
CB Fail (50BF)
344
Element Blocking
345
Voltage Transformer Supervision (60VTS)
346
Or 2 Phase VT Fail
346
Phase VT Fail
347
Current Transformer Supervision (60CTS)
348
7Sr11
348
7Sr12
349
Broken Conductor (46BC)
350
Trip/Close Circuit Supervision (74T/CCS)
352
Magnetising Inrush Detector (81HBL)
353
Section 4: Control & Logic Functions
354
Autoreclose (79)
354
Quick Logic
354
Section 5: Testing and Maintenance
355
Periodic Tests
355
Maintenance
355
Troubleshooting
356
The Copyright and Other Intellectual Property Rights in this Document, and in any Model or Article Produced from It (and Including
357
Table of Contents
359
Section 1: Common Functions
361
Multiple Settings Groups
361
Binary Inputs
362
Alarm and Tripping Inputs
362
AC Rejection
362
Use of Binary Inputs in Control and Tripping Circuits
364
Capacitance Discharge Current in Centre Tapped Battery Installations
364
Binary Outputs
366
Leds
366
Section 2: Protection Functions
367
Time Delayed Overcurrent (51/51G/51N)
367
Selection of Overcurrent Characteristics
368
Reset Delay
369
Voltage Dependent Overcurrent (51V)
370
Cold Load Settings (51C)
370
Arc Flash Detection (50AFD)
371
Instantaneous Overcurrent (50/50G/50N)
372
Blocked Overcurrent Protection Schemes
372
Sensitive Earth-Fault Protection (50SEF)
374
Directional Protection (67)
375
Out of 3 Logic
377
Directional Earth-Fault (50/51G, 50/51N, 50/51SEF)
378
Compensated Coil Earthing Networks
378
Isolated Networks
381
Minimum Polarising Voltage
381
High Impedance Restricted Earth Fault Protection (64H)
382
Negative Phase Sequence Overcurrent (46NPS)
383
Undercurrent (37)
384
Thermal Overload (49)
384
Under/Over Voltage Protection (27/59)
385
Neutral Overvoltage (59N)
386
Application with Capacitor Cone Units
387
Derived NVD Voltage
387
Negative Phase Sequence Overvoltage (47)
387
Power (32)
389
Sensitive Power (32S)
389
Power Factor (55)
389
Section 3: CT Requirements
390
CT Requirements for Overcurrent and Earth Fault Protection
390
Overcurrent Protection Cts
390
Earth Fault Protection Cts
390
CT Requirements for High Impedance Restricted Earth Fault Protection
390
Section 4: Control Functions
391
Auto-Reclose Applications
391
Auto-Reclose Example 2, Simple Multishot Sequence
393
Auto-Reclose Example 3, Simple Single Shot Sequence
394
Auto-Reclose Example 4 (Use of Quicklogic with AR)
395
Auto-Changeover Scheme Example
396
Section 5: Supervision Functions
397
Circuit-Breaker Fail (50BF)
397
Settings Guidelines
397
Current Transformer Supervision
399
Voltage Transformer Supervision (60VTS)
400
Trip/Close Circuit Supervision (74T/CCS)
401
Trip Circuit Supervision Connections
401
Close Circuit Supervision Connections
403
Inrush Detector (81HBL2)
403
Broken Conductor / Load Imbalance (46BC)
403
Broken Conductor Example
404
Circuit-Breaker Maintenance
404
Advertisement
Siemens Argus 7SR12 Manual (76 pages)
Brand:
Siemens
| Category:
Relays
| Size: 2.35 MB
Table of Contents
Table of Contents
2
Section 1: Introduction
7
Current Transformer Circuits
7
1.2 External Resistors
7
1.3 Front Cover
7
Table 1-1 7SR11 Ordering Options
8
Figure 1-1 Functional Diagram of 7SR1101-1_A12-_CA0 Relay
9
Figure 1-2 Functional Diagram of 7SR1101-3_A12-_CA0 Relay
9
Figure 1-3 Functional Diagram of 7SR1103-1_A12-_DA0 Relay
9
Figure 1-4 Functional Diagram of 7SR1103-3_A12-_DA0 Relay
9
Figure 1-5 Connections Diagram for 7SR11 Relay
10
Table 1-2 7SR12 Ordering Options
11
Figure 1-6 Functional Diagram of 7SR1204-2_A12-_CA0 Relay
12
Figure 1-7 Functional Diagram of 7SR1204-4_A12-_CA0 Relay
12
Figure 1-8 Functional Diagram of 7SR1205-2_A12-_DA0 Relay
13
Figure 1-9 Functional Diagram of 7SR1205-4_A12-_DA0 Relay
13
Figure 1-10 Connections Diagram for 7SR12 Relay
14
Section 2: Hardware Description
15
General
15
Case
15
Table 1-3 Summary of 7SR1 Relay Configurations
15
Front Cover
16
Figure 1-11 Relay Shown Withdrawn
16
Figure 1-12 7SR11 Rear View of 7SR11 Relay
16
Figure 1-13 Earth Connection Symbol
16
Power Supply Unit (PSU)
17
Figure 1-14 Relay with Standard Transparent Cover
17
Figure 1-15 Relay with Transparent Cover and Push Buttons
17
Operator Interface/ Fascia
18
Figure 1-16 Relay with Transparent Cover Removed
18
Figure 1-17 Close up of Relay Label
18
Figure 1-18 Close up of Relay Identifier
19
Current Inputs
21
Voltage Inputs
21
Binary Inputs
21
Figure 1-19 LED Indication Label
21
Binary Outputs (Output Relays)
22
Figure 1-20 Binary Input Logic
22
2.10 Virtual Input/Outputs
23
Figure 1-21 Binary Output Logic
23
2.11 Self Monitoring
24
2.11.1 Protection Healthy/Defective
24
Figure 1-22 Start-Up Counter Meter
24
Figure 1-23 Start-Up Events
25
Section 3: Protection Functions
26
Current Protection: Phase Overcurrent (67, 51, 50)
26
Directional Control of Overcurrent Protection (67) - 7SR12
26
Instantaneous Overcurrent Protection (50)
27
Figure 1-24 Logic Diagram: Directional Overcurrent Element (67)
27
Time Delayed Overcurrent Protection (51)
28
Figure 1-25 Logic Diagram: Instantaneous Over-Current Element
28
Figure 1-26 Logic Diagram: Time Delayed Overcurrent Element
29
Current Protection: Voltage Controlled Overcurrent (51V) - 7SR12
30
Figure 1-27 Logic Diagram: Voltage Controlled Overcurrent Protection
30
Current Protection: Derived Earth Fault (67N, 51N, 50N)
31
Directional Control of Derived Earth Fault Protection (67N) - 7SR12
31
Figure 1-28 Logic Diagram: Derived Directional Earth Fault Element
31
Instantaneous Derived Earth Fault Protection (50N)
32
Time Delayed Derived Earth Fault Protection (51N)
32
Figure 1-29 Logic Diagram: Derived Instantaneous Earth Fault Element
32
Figure 1-30 Logic Diagram: Derived Time Delayed Earth Fault Protection
33
Current Protection: Measured Earth Fault (67G, 51G, 50G)
34
Directional Control of Measured Earth Fault Protection (67G) - 7SR12
34
Figure 1-31 Logic Diagram: Measured Directional Earth Fault Protection
34
Instantaneous Measured Earth Fault Protection (50G)
35
Figure 1-32 Logic Diagram: Measured Instantaneous Earth-Fault Element
35
Time Delayed Measured Earth Fault Protection (51G)
36
Figure 1-33 Logic Diagram: Measured Time Delayed Earth Fault Element (51G)
36
Current Protection: Sensitive Earth Fault (67SEF, 51SEF, 50SEF)
37
Directional Control of Sensitive Earth Fault Protection (67SEF) - 7SR12
37
Instantaneous Sensitive Earth Fault Protection (50SEF)
38
Figure 1-34 Logic Diagram: SEF Directional Element (67SEF)
38
Figure 1-35 Logic Diagram: 7SR11 SEF Instantaneous Element
38
Figure 1-36 Logic Diagram: 7SR12 SEF Instantaneous Element
39
Time Delayed Sensitive Earth Fault Protection (51SEF)
40
Figure 1-37 Logic Diagram: 7SR11 SEF Time Delayed Element (51SEF)
40
Figure 1-38 Logic Diagram: 7SR12 SEF Time Delayed Element (51SEF)
41
Current Protection: High Impedance Restricted Earth Fault - (64H)
42
Current Protection: Cold Load (51C)
42
Figure 1-39 Logic Diagram: High Impedance REF (64H)
42
Current Protection: Negative Phase Sequence Overcurrent - (46NPS)
43
Figure 1-40 Logic Diagram: Cold Load Settings (51C)
43
Current Protection: Under-Current (37)
44
Figure 1-41 Logic Diagram: Negative Phase Sequence Overcurrent (46NPS)
44
Figure 1-42 Logic Diagram: Phase Current Inputs Undercurrent Detector (37)
44
Current Protection: Thermal Overload (49)
45
Figure 1-43 Logic Diagram: Earth Current Inputs Undercurrent Detector (37G)
45
Figure 1-44 Logic Diagram: Sensitive Earth Current Inputs Undercurrent Detector (37SEF)
45
Current Protection: Line Check 50LC, 50G LC and 50SEF LC - Only Software Option 'C
46
Figure 1-45 Logic Diagram: Thermal Overload Protection (49)
46
Figure 1-46 Logic Diagram: 50G Line Check Elements (50G LC)
46
Voltage Protection: Phase Under/Over Voltage (27/59) - 7SR12
47
Figure 1-47 Logic Diagram: 50SEF Line Check Elements (50SEF LC)
47
Figure 1-48 Logic Diagram: 50 Line Check Elements (50LC)
47
Figure 1-49 Logic Diagram: Under/Over Voltage Elements (27/59)
48
Voltage Protection: Negative Phase Sequence Overvoltage (47) - 7SR12
49
3.13 Voltage Protection: Neutral Overvoltage (59N) - 7SR12
49
Figure 1-50 Logic Diagram: NPS Overvoltage Protection (47)
49
3.14 Voltage Protection: Under/Over Frequency (81) - 7SR12
50
Figure 1-51 Logic Diagram: Neutral Overvoltage Element (59N)
50
Figure 1-52 Logic Diagram: Under/Over Frequency Detector (81)
51
Section 4: Control & Logic Functions
52
Auto-Reclose (79) Optional Function
52
Overview
52
Auto Reclose Sequences
53
Autoreclose Prot'n Menu
54
Autoreclose Config Menu
54
Figure 4-1 Typical AR Sequence with 3 Inst and 1 Delayed Trip
54
P/F Shots Sub-Menu
56
E/F Shots Sub-Menu
56
SEF Shots Sub-Menu
56
Extern Shots Sub-Menu
56
Figure 4-2 Basic Auto-Reclose Sequence Diagram
58
Manual CB Control
59
Circuit Breaker (CB)
59
Figure 4-3 Logic Diagram: Circuit Breaker Status
60
Quick Logic
62
Figure 4-4 Sequence Diagram: Quick Logic PU/DO Timers (Counter Reset Mode Off)
63
Section 5: Supervision Functions
64
Circuit Breaker Failure (50BF)
64
Figure 4-5 Logic Diagram: Circuit Breaker Fail Protection (50BF)
64
VT Supervision (60VTS) - 7SR1205 & 7SR1206
65
Figure 4-6 Logic Diagram: VT Supervision Function (60VTS)
66
CT Supervision (60CTS)
67
60CTS for 7SR11 (60CTS-I for 7SR12)
67
60CTS for 7SR12
67
Figure 4-7 Logic Diagram: CT Supervision Function (60CTS) - 7SR11
67
Broken Conductor (46BC)
68
Trip/ Close Circuit Supervision (74TCS & 74CCS)
68
Figure 4-9 Logic Diagram: CT Supervision Function (60CTS) - 7SR12
68
Figure 4-10 Logic Diagram: Broken Conductor Function (46BC)
68
Figure 4-11 Logic Diagram: Trip Circuit Supervision Feature (74TCS)
69
Figure 4-12 Logic Diagram: Close Circuit Supervision Feature (74CCS)
69
2Nd Harmonic Block/Inrush Restraint (81HBL2) Phase Elements Only
70
Figure 4-13 Functional Diagram for Harmonic Block Feature (81HBL2)
70
Section 6: Other Features
71
Data Communications
71
Maintenance
71
Output Matrix Test
71
CB Counters
71
I 2 T CB Wear
71
Data Storage
71
General
71
Demand
72
Event Records
72
Waveform Records
72
Fault Records
73
Energy Storage - 7SR12
73
Figure 4-14 Energy Direction Convention
73
Metering
74
Operating Mode
75
Control Mode
75
Real Time Clock
75
Table 4-1 Operating Mode
75
2012 Siemens Protection Devices Limited Chapter
76
Time Synchronisation - Data Communication Interface
76
Time Synchronisation - Binary Input
76
Settings Groups
76
Password Feature
76
Siemens Argus 7SR12 Manual (21 pages)
Overcurrent Relays, Answers for energy
Brand:
Siemens
| Category:
Relays
| Size: 1.27 MB
Table of Contents
Monitoring Functions
2
Function Matrix
3
Description of Functionality
4
Serial Communications
7
User Interface
9
Technical Data
10
Inputs and Outputs
10
Unit Design
10
Serial Interface
11
Electrical Tests
11
Data Storage
11
Mechanical Tests
11
Climatic Tests
12
Case Dimensions
15
Advertisement
Advertisement
Related Products
Siemens Argus 7SR11
Siemens 7SR18 Solkor
Siemens 7SR105 Rho
Siemens 7SR10 Argus Series
Siemens 7SR1003 Argus
Siemens 7SR1002 Argus
Siemens 7SR1004 Argus
Siemens 7SR158 Argus
Siemens 7SR17 Rho
Siemens 7SR23 DAD
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL