Siemens RVD230 Manuals
Manuals and User Guides for Siemens RVD230. We have
1
Siemens RVD230 manual available for free PDF download: Basic Documentation
Siemens RVD230 Basic Documentation (130 pages)
District Heating and Domestic Hot Water Controller
Brand:
Siemens
| Category:
Controller
| Size: 1.61 MB
Table of Contents
Table of Contents
3
1 Summary
13
Brief Description and Key Features
13
Type Summary
13
Equipment Combinations
13
Suitable Sensors
13
Suitable Room Units
14
Suitable Valve Actuators
14
Communication
14
Documentation
14
2 Use
15
Types of Plant
15
Types of Houses and Buildings
15
Types of Heating Systems
15
Heating Circuit Functions
15
Functions
16
Auxiliary Functions
16
3 Fundamentals
17
Key Technical Features
17
Function Blocks
17
Plant Types
17
Operating Modes
23
Heating Circuit Control
23
Heating
23
Manual Operation
23
4 Acquisition of Measured Values
24
General
24
Flow Temperature (B1, B12)
24
Types of Sensors
24
Handling Faults
24
Outside Temperature (B9)
24
Room Temperature (A6)
25
Types of Sensors
25
Handling Faults
25
Room Model
25
Flow Temperature (B3 and B12)
25
Measuring Variable
25
Handling Faults
26
Storage Tank Temperature (B31)
26
Measuring Variable
26
Types of Sensors
26
Storage Tank or Return Temperature (B32)
27
Measuring Variable
27
Types of Sensors
27
Handling Faults
27
Primary Return Temperature (B7, B71 and B72)
27
Measurement
27
Secondary Return Temperature (B7 and B71)
28
Measurement
28
Types of Sensors
28
Handling Faults
28
5 Function Block Space Heating
29
Operating Lines
29
Settings and Displays
29
Heating Program
30
6 Function Block Clock Settings
31
Operating Lines
31
Entries
31
7 Function Block End-User D.h.w
32
Operating Lines
32
Heating Program
32
Adjustment of Setpoints
32
8 Function Block Display of Actual Sensor Values
33
Operating Lines
33
Displays
33
9 Function Block Holiday Settings
34
Operating Lines
34
Holiday Program
34
10 Function Block Indication of Errors
35
Operating Line
35
Indication of Errors
35
11 Function Block Plant Configuration
36
Operating Lines
36
Parameters to be Set
36
Plant Type
36
Input B71 / U1
36
Circulating Pump
37
Input H5
37
Control of Variable Speed Pump
37
12 Function Block Space Heating
41
Operating Lines
41
Compensating Variables
41
Outside Temperature
41
Room Temperature
42
Heating Curve
43
Generation of Setpoint
44
Display of Setpoint
44
Setpoint of Weather-Compensated Control
44
Setpoint of Room-Compensated Control
45
Setpoint of Weather-Compensated Control with Room Influence
45
Heating Circuit Control
46
Weather-Compensated Control
46
Room-Compensated Control
46
Weather-Compensated Control with Room Influence
46
Automatic ECO Function
47
Fundamentals
47
Compensating Variables and Auxiliary Variables
47
Heating Limit
48
Mode of Operation of ECO Function 1
48
Mode of Operation of ECO Function 2
48
Pump Overrun
48
Maximum Limitation of the Room Temperature
48
Optimization
49
Definition and Purpose
49
Fundamentals
49
Process
50
Room Model Temperature
50
Optimum Stop Control
51
Quick Setback
51
Optimum Start Control
51
Maximum Rate of Flow Temperature Increase
52
Frost Protection for the Building
52
General
52
Mode of Operation with Room Sensor
52
Mode of Operation Without Room Sensor
53
Protective Functions
53
Pump Kick
53
Valve Kick
53
Shutdown of Pump
53
13 Precontrol
54
General
54
Heat Demand
54
Control
54
Pump Q1
54
Pump and Mixing Valve Overrun
54
Frost Protection
55
Other Functions
55
Room Unit
56
14 Function Block Valve Actuator Heat Converter / Primary Controller
57
Operating Lines
57
Mode of Operation
57
Control Process
57
Maximum Limitation of the Flow Temperature
57
Minimum Limitation of the Flow Temperature
58
External Heat Demand at Input H5
58
External Heat Demand at Input U1
58
15 Function Block Valve Actuator Heating Circuit
60
Operating Lines
60
Mode of Operation
60
Control Process
60
Maximum Limitation of the Flow Temperature
60
Minimum Limitation of the Flow Temperature
61
16 Function Block D.h.w. Heating
62
Operating Lines
62
Release of D.h.w. Heating
62
Control of the Circulating Pump
63
Switching Differential of D.h.w. Control
63
Legionella Function
63
Priority of D.h.w. Heating
63
General
63
Absolute Priority
64
Shifting Priority
64
No Priority
65
Pump Overrun
65
General
65
Intermediate Circuit Pump
65
Storage Tank Charging Pump
65
Frost Protection for D.h.w
66
Switching D.h.w. Heating off
66
17 H.w. Heating
67
Heating with Storage Tanks
67
General
67
Maximum Charging Time
67
Manual Storage Tank Charging
67
Forced Charging
67
Protection against Discharging
68
Heating with Diverting Valve
68
Protection against Overtemperatures
68
Storage Tank with Electric Immersion Heater
68
Heating with Stratification Storage Tank
69
General
69
Heating with One Flow Sensor
69
Heating with 2 Flow Sensors
69
Feeding the Circulating Water into the Heat Exchanger
70
Direct D.h.w. Heating
70
General
70
Heating
70
Protection against Cooling down
70
Siting the Sensors
71
Flow Switch
71
Compensation of Heat Losses through Control
72
Cold Water Sensor
73
Plant Type 8-4
73
18 Function Block Extra Legionella Functions
74
Operating Lines
74
Legionella Function
74
Setpoint
74
Time
74
Dwelling Time
74
Operation of Circulating Pump
75
Maximum Limitation of the Return Temperature
75
Mode of Operation
75
19 Function Block Valve Actuator D.h.w
77
Operating Lines
77
Mode of Operation
77
Control Process
77
Setpoint Boost
78
Charging Boost
78
Flow Temperature Boost
78
Maximum Setpoint of the D.h.w. Temperature
78
Heating with 2 Storage Tank Sensors
78
Adjustable Load Limit
79
Adjustment to the Time of Year
79
Load Limit
79
Child-Proofing
79
20 Function Block Assignment of D.h.w. Heating
80
Operating Line
80
Assignment of D.h.w. Heating
80
21 Function Block LPB Parameters
81
Operating Lines
81
LPB Parameters
81
Addressing the Devices
81
Source of Time of Day
81
Bus Power Supply
82
Outside Temperature Source
82
22 Locking Signals
83
Fundamentals
83
Critical Locking Signals
83
Uncritical Locking Signals
84
General
84
Controller-Internal Uncritical Locking Signals
84
Uncritical Locking Signals from the Data Bus
84
23 Function Block Device Functions
85
Operating Lines
85
Actuator Pulse Lock
85
Frost Protection for the Plant
85
Principle
85
Mode of Operation with Outside Sensor
85
Mode of Operation Without Outside Sensor
86
Frost Protection for the Heating Circuit Flow
86
Flow Alarm
86
Heating Circuit and D.h.w. Circuit with Storage Tanks
86
Direct D.h.w. Heating Via Heat Exchanger
87
Winter- / Summertime Changeover
88
Pump Kick
88
24 Function Block M-Bus Parameters
89
Operating Lines
89
General
89
Addressing and Identification
89
Baud Rate
89
Load Management
89
Load Management of D.h.w
89
Load Management of the Heating System
90
Resetting the Load Control Signals
90
Use on the LPB
90
Resolution of M-Bus Signals
90
25 Function Block PPS Parameters
91
Operating Line
91
Function
91
26 Function Block Test and Display
92
Operating Lines
92
Sensor Test
92
Setpoint Test
92
Relay Test
93
Display of Pump Speed
93
Display of Digital Inputs
93
Limitations
94
Software Version
94
27 Function Block DRT and Maximum Limitation of the Return Temperature
95
Operating Lines
95
Maximum Limitation of the Primary Return Temperature
95
General
95
Maximum Limitation in Heating Mode
96
Maximum Limitation in D.h.w. Heating Mode
97
Maximum Limitation of the Secondary Return Temperature
97
Maximum Limitation of the Temperature Differential (DRT Function)
98
Mode of Operation
98
Purpose
98
Integral Action Time of the Limitation Functions
99
28 Function Block Miscellaneous
100
Operating Lines
100
Limitation Function at Contact H5
100
Suppression of Hydraulic Creep
101
Mode of Operation
101
Raising the Reduced Room Temperature Setpoint
101
29 Function Block Operation Locking Functions
103
Operating Lines
103
Locking Settings on the Software Side
103
Locking of Setting Level "Locking Functions" on the Hardware Side
103
30 Combination with PPS Devices
104
General
104
Combination with Room Unit QAW50
104
Overriding the Operating Mode
104
Knob for Room Temperature Readjustments
105
Controller with Operation Lock
105
Combination with Room Unit QAW70
105
General
105
Overriding the Operating Mode
106
Knob for Readjusting the Room Temperature
106
Effects of the Individual QAW70 Operating Lines on the RVD230
106
Controller with Operation Lock
107
Entry of Holiday Periods
107
Room Temperature Sensor QAA10
107
31 Manual Operation
108
32 Handling
109
Operation
109
General
109
Analog Operating Elements
110
Digital Operating Elements
110
Controller in "Nonoperated State
111
Safety Concept
111
Setting Levels and Access Rights
111
Commissioning
111
Installation Instructions
111
Operating Lines
112
Installation
112
Mounting Location
112
Mounting Choices
112
Electrical Installation
112
33 Engineering
113
Connection Terminals
113
Relays
114
PWM Output
114
Lightning Protection in M-Bus Plants
114
Connection Diagrams
115
Low-Voltage Side
115
Mains Voltage Side
115
34 Mechanical Design
116
Basic Design
116
Dimensions
116
35 Technical Data
117
Advertisement
Advertisement
Related Products
Siemens RVD110
Siemens RVD130
Siemens RVS61.843
Siemens RVA63.242
Siemens RVA63.280
Siemens RVP36
Siemens RVP540
Siemens RVP360
Siemens RVP201.0
Siemens RVP211
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL