SIMOTICCS A 1FU9
User Manuals: Siemens SIMOTICCS A 1FU9 Motor
Manuals and User Guides for Siemens SIMOTICCS A 1FU9 Motor. We have
1
Siemens SIMOTICCS A 1FU9 Motor manual available for free PDF download: Operating Instructions Manual
Siemens SIMOTICCS A 1FU9 Operating Instructions Manual (126 pages)
Synchronous
Brand:
Siemens
| Category:
Engine
| Size: 2.89 MB
Table of Contents
Table of Contents
5
1 Introduction
11
About These Instructions
11
Compiling Personal Documents
11
2 Safety Information
13
Information for those Responsible for the Plant or System
13
The 5 Safety Rules
13
Qualified Personnel
14
Safe Handling
14
Dangerous Voltage When the Rotor Rotates
16
Electromagnetic Fields When Operating Electrical Power Engineering Installations
16
Electrostatic Sensitive Devices
16
Interference Immunity
17
Interference Voltages When Operating the Converter
18
Thermal Hazard
18
Information about Electromagnetic Fields
18
Special Designs and Construction Versions
19
3 Description
21
Area of Application
21
Correct and Intended Use
21
CE Marking
21
Rating Plates
22
Rating Plate
22
Installation
23
Machine Version Synchronous Machines
23
Regulations for Synchronous Motors
23
Cooling and Ventilation
24
Machines with a Fan
24
Machines Without a Fan (Optional)
25
Bearings of Synchronous Machines
25
Balancing
25
Types of Construction/Method of Installation
26
Degree of Protection
27
Environmental Conditions
27
Optional Built-On and Built-In Accessories
27
Paint Finish
28
4 Preparing for Use
29
Introduction
29
Safety-Related Aspects to Consider When Configuring the Plant
29
Observing the Operating Mode
29
Delivery
29
Transport and Storage
30
Reference to Chapter Safety Instructions
30
Transporting Certain Frame Sizes
31
Types of Construction on the Rating Plate
31
Storage
31
Commissioning after Storage
33
Insulation Resistance and Polarization Index
33
Lubricating the Rolling Bearings
33
Regreasing Rolling Bearings after Storage Periods of up to Two Years
34
Releasing the Rotor Shipping Brace before Commissioning
34
Ensure Adequate Cooling
34
Noise Emission
36
Rotational Speed Limit Values
36
System-Inherent Frequencies
36
Electromagnetic Compatibility
37
EMC and Interference Immunity
37
Converter Operation
37
Parameterizing the Converter
38
Converter Input Voltage
38
Reducing Bearing Currents During Operation with Converter (Low Voltage)
38
Insulated Bearings for Converter Operation
40
Speed Limits for Converter Operation
41
5 Assembly
43
Reference to Chapter Safety Instructions
43
Loss of Conformity with European Directives
43
Preparing for Installation
43
Requirements for Installation
43
Safety Instructions
43
Insulation Resistance
44
Insulation Resistance and Polarization Index
44
Checking the Insulation Resistance and Polarization Index of the Winding
45
Installing the Machine
48
Preparing the Assembly Area
48
Safety Instructions for Installation
48
Lift the Machine to Where It will be Mounted and Position It
49
Machines with Type of Construction IM B15, IM B9, IM V8 and IM V9
49
Foot Mounting
50
Alignment and Fastening
50
Flatness of the Supporting Surfaces for Conventional Motors
51
Machine Frame Mounting Feet (Special Design)
51
Installing the Machine
52
Preconditions for Smooth, Vibration-Free Operation
52
Aligning the Machine to the Driven Machine and Mounting
52
Selecting Bolts
52
Horizontal Types of Construction with Mounting Feet
52
Horizontal Types of Construction with Flange
53
Vertical Types of Construction with Flange
53
Removing the Rotor Shipping Brace
54
Recommended Alignment Accuracy
54
Mounting the Drive Output Elements
54
Axial and Radial Forces
57
6 Electrical Connection
59
Reference to Chapter Safety Instructions
59
Connected Parts Can Become Loose
59
Preparation
59
Selecting Cables
59
Connecting the Machine
60
Terminal Box
61
Terminal Designations
62
Circuit Diagram Inside the Terminal Box Cover
62
Cable Entry
62
Versions
62
Protruding Connection Cables
63
Connecting Protruding Cables
63
Connection With/Without Cable Lugs
63
Minimum Air Clearances
64
Cable Glands
65
Mounting Position of Sheet Metal Nuts in Screw-Type Connections
65
Tightening Torques
66
Cable Entries, Sealing Plugs and Thread Adapters
66
Connecting the Grounding Conductor
66
General Information on Connecting the Grounding Conductor
66
Minimum Surface Area of Grounding Conductor
67
Grounding Connection Type
67
Size of Grounding Conductor Screw
68
Connecting the Temperature Sensor
68
Connecting Optional Integrated Devices and Equipment
68
Auxiliary Circuit Connection
69
Conductor Connection
69
General Information on Conductor Connection
69
Type of Conductor Connection
70
Connecting Aluminum Conductors
71
Connecting Converters
71
Final Checks
72
7 Commissioning
73
Reference to Chapter Safety Instructions
73
Measures before Commissioning
73
Checks to be Carried out Prior to Commissioning
73
Mechanical Checks
74
Insulation Resistance and Polarization Index
75
Testing the Cooling of the Machine
75
Commissioning an External Fan
76
Further Documents
76
Setpoint Values for Monitoring the Bearing Temperature
77
Dangerous Voltage When the Rotor Rotates
77
Switching on
78
Measures Required for Commissioning and Test Operation
78
8 Operation
81
Reference to Chapter Safety Instructions
81
Safety Instructions for Operation
81
Safety Instructions Relating to Ventilation and Cooling
84
Safety Instruction for Forced Ventilation (Option)
84
Safety Instructions When Operating Machines with Fan
84
Machines with Fan for the Textile Industry
84
Dangerous Voltage When the Rotor Rotates
85
Switching on the Machine
85
Switch off the External Fan
85
Switching on Again after an Emergency Switching-Off
86
Stoppages
86
Avoidance of Damage to Rolling Bearings During Stoppages
87
Decommissioning the Machine
87
Re-Commissioning the Machine
87
Faults
88
Inspections in the Event of Faults
88
Electrical Faults
88
Mechanical Faults
89
Rolling Bearing Faults
89
Faults at the External Fan
90
Deactivating
90
9 Maintenance
91
General
91
Reference to Chapter Safety Instructions
91
Service Center
91
Safety Instructions for Inspection and Maintenance
91
Preparation and Notes
93
Danger When Openly Storing Rotors
93
Touch up any Damaged Paintwork
93
Inspection and Maintenance
94
Safety Instructions for Inspection and Maintenance
94
Inspections in the Event of Faults
95
First Inspection after Installation or Repair
95
General Inspection
96
Assessing the Rolling Bearings
97
Maintenance Intervals
97
Re-Greasing
98
Cleaning
99
Cleaning the Fan Cover of Machines for the Textile Industry
99
Drain Condensate
100
Insulation Resistance and Polarization Index
100
Servicing the External Fan
101
Corrective Maintenance
101
Reference to Chapter Safety Instructions
101
Rolling Bearings
102
Bearing Bushes
103
Installing Rolling Bearings
104
Mounting Dimension "X
105
Fan
106
Metal Fan Disassembly
106
Mounting Fans
107
Screw Lock Washers
107
Links
107
Reassembly: Miscellaneous Information
107
Optional Add-On Units
107
O-Ring Seal
108
10 Spare Parts
109
11 Disposal
111
Introduction
111
Country-Specific Legislation - LV Machines
111
Rohs - Restricting the Use of Certain Hazardous Substances
111
Information According to Article 33 of the REACH Regulation
111
Preparing for Disassembly
112
Dismantling the Machine
112
Disposal of Components
113
Service & Support
115
Siemens Industry Online Support
115
SIOS App
116
Further Documents
116
Technical Data
117
Tightening Torques
117
Tightening Torques for Screw and Bolt Connections
117
Terminal Board and Grounding
118
Terminal Boxes, End Shields, Grounding Conductors, Sheet Metal Fan Covers
118
Cable Glands
118
Additional Connecting Terminals for Monitoring Equipment
119
Index
121
Advertisement
Advertisement
Related Products
Siemens SIMOTICS A 1FU8
Siemens SIMOTICS A-1FV5
Siemens SIMOTICS A-1PV5
Siemens AH 180
Siemens A5E00215729A
SIEMENS Gigaset A160
SIEMENS Gigaset A165
SIEMENS Gigaset A120
SIEMENS Gigaset A100
Siemens Gigaset A18H
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL