Sign In
Upload
Manuals
Brands
Siemens Manuals
Industrial PC
SIMOTION P320-4 S
Siemens SIMOTION P320-4 S Manuals
Manuals and User Guides for Siemens SIMOTION P320-4 S. We have
4
Siemens SIMOTION P320-4 S manuals available for free PDF download: Commissioning And Hardware Installation Manual, Manual
Siemens SIMOTION P320-4 S Commissioning And Hardware Installation Manual (222 pages)
Brand:
Siemens
| Category:
Controller
| Size: 9.17 MB
Table of Contents
Industrial Security
3
Preface
3
Description of the Installation, Mounting and Assembly of the SIMOTION P320
4
Table of Contents
7
1 Safety Notes
13
Fundamental Safety Instructions
13
General Safety Instructions
13
Safety Instructions for Electromagnetic Fields (EMF)
16
Handling Electrostatic Sensitive Devices (ESD)
16
Industrial Security
17
Danger to Life Due to Software Manipulation When Using Removable Storage Media
18
Residual Risks of Power Drive Systems
18
Specific Safety Instructions for SIMOTION P320-4
19
General Safety Instructions for the SIMOTION P320-4
19
Notes on Use
22
2 Industrial Security
23
Security Concept for SIMOTION P320-4
23
Security
23
Why Is Industrial Security so Important
25
Trends in the IT Sector
26
Possible Corporate Security Holes
26
General Security Measures
27
Overview
27
Plant Security
29
Physical Protection of Critical Production Areas
29
Network Security
30
Network Segmentation
30
System Integrity
33
System Hardening
33
Product-Specific Measures
35
Virus Scanners, Windows Security Patches, SIMOTION P
35
Changing the Windows User Password
36
Changing the Autologin
40
SIMOTION P Autologin
40
Deactivating the Remote Desktop Connection
47
3 Description
51
System Overview
51
SIMOTION P320-4 Product Description
52
SIMOTION P320-4 Overview
52
Features
53
SIMOTION P320-4 (Hardware) Structure
55
Interfaces and Operating Elements
56
SIMOTION P Runtime (Software) Structure
56
Components
57
HMI and SIMOTION SCOUT
59
HMI and SIMOTION SCOUT Overview
59
Local HMI or es on SIMOTION P320-4
60
Setting up a Network Bridge - MAC Bridge Miniport
61
HMI or es Via PROFINET
72
HMI or es Via Ethernet
73
HMI or es Via Isoprofibus (Optional)
75
4 Use Planning
77
5 Mounting
79
Installation Overview
79
Headless Operation
79
SIMOTION P320-4 - Headless Operation
79
Deactivating the Remote Desktop Connection
80
Decentralized Structure
82
Important Information about Installation
82
Withdrawing/Inserting the Cfast Card
83
Automatic Restart for SIMOTION P Runtime
86
Installing the SIMOTION P320-4 in the Control Cabinet
87
Notes on Installation
87
Standard Rail Mounting
88
Vertical Mounting
91
SIMOTION P Autologin
91
6 Connection
99
Connection Requirements
99
Overview of Connections
100
Connecting PROFINET
101
PROFINET Onboard
101
Connection
102
Mounting a Strain Relief
103
Connecting PROFIBUS
104
Requirement
104
SYNC I/O Connecting Cable / Plugging in the Isoprofibus Board
105
Connecting the Isoprofibus Board
107
Isoprofibus Board and PROFIBUS DP
110
Connecting the Bus Connectors for the X101 and X102 Interfaces (Isoprofibus)
110
PROFIBUS Cable
111
Connecting Ethernet
112
Connecting the Keyboard and Mouse
113
Connecting the Power Supply
113
Safety Rules
113
Standards and Regulations
114
Connecting the Power Supply
114
Protective Conductor Connection and Potential Equalization
115
7 Power on and Software Installation
117
Power-Up
117
Additional Software for HMI
118
Customer-Specific Software
118
8 Operator Control (Hardware)
119
SIMOTION P State Application
119
SIMOTION P State Application Overview
119
LED Display
120
Mode Selector
121
Current Operating Status
122
Function Elements
122
SIMOTION P State - Menus
123
9 Parameter Assignment/Addressing
127
Parameter Assignment / Addressing Requirements
127
Factory Settings
127
Factory Settings Overview
127
Ethernet - TCP/IP Local
127
SIMOTION P Control Manager
128
Requirement
128
SIMOTION P Control Manager Overview
128
Calling SIMOTION P Control Manager from the Control Panel
128
Administration Tab
129
Start SIMOTION P
131
Automatic Restart by Plug-In External Memory Card
132
Runtime Network Connections
133
License Tab
135
Local Communication Via PC Internal
137
Local Communication (PC-Internal) Overview
137
Checking the PC-Internal Settings
137
Station Configurator
138
Ethernet Communication
140
Ethernet Communication Overview
140
Ethernet Interface
141
Default IP Addresses for Windows and SIMOTION P Runtime
143
Communication Via an Ethernet Interface
143
Establishing the Active Flag for an External PG/PC
147
PROFINET Communication
148
Documentation
148
PROFIBUS Communication
148
Project Download
149
Battery Monitoring
151
10 Commissioning (Software)
153
Note before Commissioning
153
Basic Commissioning - Initial Startup
153
Commissioning Requirements
153
Notes on Commissioning
154
Recommended Order for First Commissioning
154
Data Backup
155
Memory Media
155
SIMATIC Data Backup
156
Restore DVD
156
Power-Up of the SIMOTION P Kernel
157
Data Storage Concept
157
Data Storage Concept Overview
157
Memory Model
160
Project Update
160
Overview
160
SIMOTION Project Download Online
161
SIMOTION SCOUT - Download of the Project Data (File Structure)
161
SIMOTION SCOUT - Download of the Project Data with SIMOTION IT (ZIP File)
162
Backing up and Restoring Project Data (File Structure)
164
Single Backups
165
Overview
165
Back Up/Restore SRAM
165
Backing up Non-Volatile SIMOTION Data (Retain Data)
166
Restoring Non-Volatile SIMOTION Data (Retain Data)
167
Save Unit Variables and Global Device Variables
168
Defined States
169
Overview
169
Restore the Factory Setting Using SIMOTION P State
169
Overall Reset Using SIMOTION P State - Operating Mode Switch Setting MRES
170
Delete SRAM Via SIMOTION P State - Button Restart (Del. SRAM)
171
SIMOTION P Overall Reset
172
SIMOTION P Overall Reset Overview
172
Overall Reset Using the Mode Selector (on Screen)
174
Deleting User Data on the Cfast Card
177
Switching off
178
11 Service and Maintenance
181
Recording Diagnostic Data
181
Restoring Factory Settings
182
Overview of Restoring the Factory Settings
182
Resetting the SIMOTION P320-4 to the Delivery Status
182
Reset SIMOTION P320-4 to the Initial State
183
Upgrading Runtime and Firmware
184
Installing/Removing the Back-Up Battery of the SIMOTION P320-4
185
Preventive Maintenance
185
Replacing the Backup Battery
185
Special Power-Up Situations
189
Special Startup Situations Overview
189
Non-Volatile Data and SRAM Handling
189
After New Installation / Update of the SIMOTION P Kernel
191
After Restoring a Backup Copy
191
After a Power Failure/Power FAIL
192
12 Alarm, Error and System Messages
193
Diagnosis Using the Leds
193
Temperature Alarm
196
Battery Alarm
197
Power Failure / POWER FAIL
197
PROFINET Bus Error Occurs
199
Under-Licensing
200
Boot Error Messages
200
13 Troubleshooting/Faqs
201
Error Correction
201
Hotplug Enabled BIOS Settings
203
Standards and Approvals
209
General Rules
209
A.1 General Rules
209
ESD Guidelines
211
ESD Definition
211
Electrostatic Charging of Individuals
211
B.1 ESD Definition
211
Basic Measures for Protection against Discharge of Static Electricity
212
List of Abbreviations
213
Commissioning Manual, Abbreviations
213
Index
215
Advertisement
Siemens SIMOTION P320-4 S Commissioning And Hardware Installation Manual (148 pages)
Brand:
Siemens
| Category:
Industrial PC
| Size: 5.08 MB
Table of Contents
Preface
3
Table of Contents
5
1 Safety Notes
9
Fundamental Safety Instructions
9
General Safety Instructions
9
Safety Instructions for Electromagnetic Fields (EMF)
12
Handling Electrostatic Sensitive Devices (ESD)
12
Industrial Security
13
Residual Risks of Power Drive Systems
13
Specific Safety Instructions for SIMOTION P320-4
15
General Safety Instructions for the SIMOTION P320-4
15
Notes on Use
17
2 Description
19
System Overview
19
SIMOTION P320-4 Product Description
20
SIMOTION P320-4 Overview
20
Features
21
SIMOTION P320-4 (Hardware) Structure
23
Interfaces and Operating Elements
24
SIMOTION P Runtime (Software) Structure
24
Components
25
HMI and SIMOTION SCOUT
27
HMI and SIMOTION SCOUT Overview
27
Local HMI or es on SIMOTION P320-4
28
HMI or es Via PROFINET
29
HMI or es Via Ethernet (External Access)
30
HMI or es Via Isoprofibus (Optional)
31
3 Use Planning
33
4 Mounting
35
Installation Overview
35
Important Information about Installation
35
Decentralized Structure
35
Installing and Removing Cfast Cards
36
Installing the SIMOTION P320-4 in the Control Cabinet
39
Notes on Installation
39
Standard Rail Mounting
39
Vertical Mounting
42
5 Connection
45
Connection Requirements
45
Overview of Connections
46
Connecting PROFINET
47
PROFINET Onboard
47
Connection
48
Mounting a Strain Relief
49
Connecting PROFIBUS
50
Requirement
50
SYNC I/O Connecting Cable / Plugging in the Isoprofibus Board
51
Connecting the Isoprofibus Board
53
Isoprofibus Board and PROFIBUS DP
56
Connecting the Bus Connectors for the X101 and X102 Interfaces (Isoprofibus)
56
PROFIBUS Cable
57
Connecting Ethernet
58
Connecting the Keyboard and Mouse
59
Connecting the Power Supply
59
Safety Rules
59
Standards and Regulations
60
Connecting the Power Supply
60
Protective Conductor Connection and Potential Equalization
61
6 Power on and Software Installation
63
Power-Up
63
Additional Software for HMI
63
Customer-Specific Software
64
7 Operator Control (Hardware)
65
SIMOTION P State Application
65
SIMOTION P State Application Overview
65
LED Display
66
Mode Selector
67
Current Operating Status
68
Function Elements
69
SIMOTION P State - Menus
69
8 Parameter Assignment/Addressing
73
Parameter Assignment / Addressing Requirements
73
Factory Settings
73
Factory Settings Overview
73
PC Internal
73
SIMOTION P Control Manager
74
Requirement
74
SIMOTION P Control Manager Overview
74
Calling SIMOTION P Control Manager from the Control Panel
74
Administration Tab
75
License Tab
78
Local Communication Via PC Internal
80
Local Communication (PC-Internal) Overview
80
Checking the PC-Internal Settings
80
Station Configurator
81
Ethernet Communication
83
Ethernet Communication Overview
83
Ethernet Interface
84
Default IP Addresses for Windows and SIMOTION P Runtime
86
Communication Via an Ethernet Interface
86
Establishing the Active Flag for an External PG/PC
90
PROFINET Communication
91
Documentation
91
PROFIBUS Communication
91
Battery Monitoring
91
9 Commissioning (Software)
93
Note before Commissioning
93
Basic Commissioning - Initial Startup
93
Commissioning Requirements
93
Notes on Commissioning
94
Recommended Order for First Commissioning
94
Data Backup
95
Memory Media
95
SIMATIC Data Backup
96
Restore DVD
96
Power-Up of the SIMOTION P Kernel
97
Data Storage Concept
97
Data Storage Concept Overview
97
Memory Model
99
Project Update
99
Overview
99
SIMOTION Project Download Online
100
SIMOTION SCOUT - Download of the Project Data (File Structure)
101
SIMOTION SCOUT - Download of the Project Data with SIMOTION IT (ZIP File)
102
Backing up and Restoring Project Data (File Structure)
103
Single Backups
104
Overview
104
Back Up/Restore SRAM
104
Backing up Non-Volatile SIMOTION Data (Retain Data)
105
Restoring Non-Volatile SIMOTION Data (Retain Data)
106
Save Unit Variables and Global Device Variables
106
Defined States
107
Overview
107
Restore the Factory Setting Using SIMOTION P State
108
Overall Reset Using SIMOTION P State - Operating Mode Switch Setting MRES
108
Delete SRAM Via SIMOTION P State - Button Restart (Del. SRAM)
109
SIMOTION P Overall Reset
110
SIMOTION P Overall Reset Overview
110
Overall Reset Using the Mode Selector (on Screen)
112
Deleting User Data on the Cfast Card
113
Switching off
113
10 Service and Maintenance
115
Recording Diagnostic Data
115
Restoring Factory Settings
116
Overview of Restoring the Factory Settings
116
Resetting the SIMOTION P320-4 to the Delivery Status
116
Reset SIMOTION P320-4 to the Initial State
117
Installing/Removing SIMOTION P320-4 Components
118
Preventive Maintenance
118
Replacing the Backup Battery
118
Special Power-Up Situations
123
Special Startup Situations Overview
123
Non-Volatile Data and SRAM Handling
123
After New Installation / Update of the SIMOTION P Kernel
125
After Restoring a Backup Copy
125
After a Power Failure/Power FAIL
125
11 Alarm, Error and System Messages
127
Diagnosis Using the Leds
127
Temperature Alarm
129
Battery Alarm
130
Power Failure / POWER FAIL
131
PROFINET Bus Error Occurs
132
Under-Licensing
132
Boot Error Messages
133
12 Troubleshooting/Faqs
135
Error Correction
135
Standards and Approvals
137
General Rules
137
A.1 General Rules
137
ESD Guidelines
139
ESD Definition
139
Electrostatic Charging of Individuals
139
B.1 ESD Definition
139
Basic Measures for Protection against Discharge of Static Electricity
140
List of Abbreviations
141
Commissioning Manual, Abbreviations
141
Index
143
Siemens SIMOTION P320-4 S Manual (166 pages)
Brand:
Siemens
| Category:
Controller
| Size: 5.54 MB
Table of Contents
Description
3
Preface
3
Simotion P320
4
Table of Contents
7
1 Safety Instructions
11
Fundamental Safety Instructions
11
General Safety Instructions
11
Safety Instructions for Electromagnetic Fields (EMF)
14
Handling Electrostatic Sensitive Devices (ESD)
14
Security Information
15
Danger to Life Due to Software Manipulation When Using Removable Storage Media
15
Residual Risks of Power Drive Systems
16
Specific Safety Instructions for the SIMOTION P320-4
17
General Safety Instructions for the SIMOTION P320-4
17
Notes on Use
19
2 Industrial Security
21
Security Concept for SIMOTION P320-4
21
Security
21
Why Is Industrial Security so Important
24
Trends in the IT Sector
24
Possible Corporate Security Holes
25
General Security Measures
26
Overview
26
Plant Security
27
Physical Protection of Critical Production Areas
27
Network Security
28
Network Segmentation
28
System Integrity
31
System Hardening
31
Patch Management
32
Product-Specific Measures
33
Virus Scanners, Windows Security Patches, SIMOTION P
33
Changing the Windows User Password
34
Changing the Autologin
38
Deactivating the Remote Desktop Connection
45
3 Description
49
System Overview
49
SIMOTION P320-4 Product Description
51
SIMOTION P320-4 Overview
51
Features
52
SIMOTION P320-4 (Hardware) Structure
54
Interfaces and Operating Elements
55
SIMOTION P Runtime (Software) Structure
55
Components
56
HMI and SIMOTION SCOUT
59
HMI and SIMOTION SCOUT Overview
59
Local HMI or es on SIMOTION P320-4
59
Setting up a Network Bridge - MAC Bridge Miniport
61
HMI or es Via PROFINET
72
HMI or es Via Ethernet
73
HMI or es Via Isoprofibus (Optional)
74
4 Application Planning
77
Unpacking and Checking the Delivery
77
Identification Data of the Device
79
Permissible Mounting Positions
82
Environmental Conditions
83
Electromagnetic Compatibility
85
5 Interfaces
87
Hardware Components of the SIMOTION P320-4
87
Overview of Operator Control and Display Elements
89
Control Elements
90
Status Displays
91
Overview of the SIMOTION P320-4 Interfaces
93
PROFINET Onboard
94
Ethernet
95
DVI-I
96
Displayport
98
Usb 3.0
99
Cfast Card
100
Com1
101
Isoprofibus Board (Optional)
102
6 Installation/Mounting
103
Installing the Device
103
Permissible Mounting Positions
104
Standard Rail Mounting and Vertical Mounting
105
Standard Rail Mounting
105
Vertical Mounting
107
Installation Notes
109
Overview of Operating Modes for the SIMOTION P320-4
111
Decentralized Structure
112
7 Connection
113
Requirements
113
Overview of Connections
114
Notes on Connecting
116
Protective Conductor Connection and Potential Equalization
118
Connecting Peripheral Equipment
120
Connecting the Power Supply (24 VDC)
121
Connecting the Device to Networks
123
Installing the Strain Relief
124
8 Troubleshooting/Faqs
125
Error Correction
125
Hotplug Enabled BIOS Settings
127
9 Technical Data
133
Overview of the Technical Specifications
133
General Technical Specifications
134
Ambient Conditions
136
Technical Data of the Isoprofibus Board
138
Power Requirements of the Components
140
Integrated DC Power Supply
141
Technical Data for the SITOP Smart 24 V/10 a
142
Typical Power Consumption
144
10 Dimension Drawings
145
Overview of the Dimensional Drawings
145
Device Dimension Drawing for Standard Rail Mounting
146
Device Dimension Drawing for Vertical Mounting
148
Dimension Drawing of Device with One Expansion Card
151
11 Spare Parts
153
Available Spare Parts for SIMOTION P320-4
153
Standards and Approvals
155
General Rules
155
A.1 General Rules
155
ESD Guideline
157
ESD Definition
157
B.1 ESD Definition
157
Electrostatic Charging of Individuals
158
Basic Measures for Protection against Discharge of Static Electricity
159
Index
161
Advertisement
Siemens SIMOTION P320-4 S Manual (118 pages)
Brand:
Siemens
| Category:
Controller
| Size: 3.18 MB
Table of Contents
Manual
2
Preface
3
Description
3
Table of Contents
7
1 Safety Instructions
11
Fundamental Safety Instructions
11
General Safety Instructions
11
Connection
11
Safety Instructions for Electromagnetic Fields (EMF)
14
Handling Electrostatic Sensitive Devices (ESD)
14
Industrial Security
15
Residual Risks of Power Drive Systems
15
Specific Safety Instructions for the SIMOTION P320-4
18
General Safety Instructions for the SIMOTION P320-4
18
Notes on Use
20
2 Description
21
System Overview
21
SIMOTION P320-4 Product Description
23
SIMOTION P320-4 Overview
23
Features
24
SIMOTION P320-4 (Hardware) Structure
26
Interfaces and Operating Elements
27
SIMOTION P Runtime (Software) Structure
27
Components
28
HMI and SIMOTION SCOUT
31
HMI and SIMOTION SCOUT Overview
31
Local HMI or es on SIMOTION P320-4
31
HMI or es Via PROFINET
32
HMI or es Via Ethernet (External Access)
33
HMI or es Via Isoprofibus (Optional)
34
3 Application Planning
37
Unpacking and Checking the Delivery
37
Identification Data of the Device
39
Permissible Mounting Positions
42
Environmental Conditions
43
Electromagnetic Compatibility
45
4 Interfaces
47
Hardware Components of the SIMOTION P320-4
47
Overview of Operator Control and Display Elements
49
Control Elements
50
Status Displays
51
Overview of the SIMOTION P320-4 Interfaces
53
PROFINET Onboard
54
Ethernet
55
DVI-I
56
Usb 3.0
58
Cfast Card
59
Com1
60
Isoprofibus Board (Optional)
61
5 Installation/Mounting
63
Installing the Device
63
Permissible Mounting Positions
64
Standard Rail Mounting and Vertical Mounting
65
Standard Rail Mounting
65
Vertical Mounting
67
Installation Notes
69
Overview of Operating Modes for the SIMOTION P320-4
71
Decentralized Structure
72
6 Connection
73
Requirements
73
Overview of Connections
74
Notes on Connecting
76
Protective Conductor Connection and Potential Equalization
78
Connecting Peripheral Equipment
80
Connecting the Power Supply (24 VDC)
81
Connecting the Device to Networks
83
Installing the Strain Relief
84
7 Troubleshooting/Faqs
85
Error Correction
85
8 Technical Data
87
Overview of the Technical Specifications
87
General Technical Specifications
88
Ambient Conditions
90
Technical Data of the Isoprofibus Board
92
Power Requirements of the Components
94
Integrated DC Power Supply
95
Technical Data for the SITOP Smart 24 V/10 a
96
Typical Power Consumption
98
9 Dimension Drawings
99
Overview of the Dimensional Drawings
99
Device Dimension Drawing for Standard Rail Mounting
100
Device Dimension Drawing for Vertical Mounting
102
Dimension Drawing of Device with One Expansion Card
105
10 Spare Parts
107
Available Spare Parts for SIMOTION P320-4
107
Standards and Approvals
109
General Rules
109
A.1 General Rules
109
ESD Guideline
111
ESD Definition
111
B.1 ESD Definition
111
Electrostatic Charging of Individuals
112
Basic Measures for Protection against Discharge of Static Electricity
113
Index
115
Advertisement
Related Products
Siemens SIMOTION P320-4 E
Siemens SIMATIC Rack PC 840 V2
Siemens SIMATIC Box PC 840
Siemens SIMATIC PC 847B
Siemens SIMATIC PC RI25/45
Siemens SIMATIC PCS 7 BOX
Siemens SIMATIC PC FI45 V2
Siemens SIMATIC Box PC 627
Siemens SIMATIC Rack PC 547B
Siemens SIMOTION ET 200S
Siemens Categories
Industrial Equipment
Controller
Control Unit
Oven
Washer
More Siemens Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL