THE INSTALLATION INSTRUCTIONS IN THIS 2. INSTALLING THE HEATER MANUAL APPLY TO THE NECTRE 15 LE. Fitting rear heat shield IT HAS BEEN TESTED FOR EMISSIONS AND EFFICIENCY The rear outer heat shield should be fitted with spacers AND COMPLIES ACCORDING TO AS/NZS 4012:1999 &...
Page 3
Positioning the Heater 2.2.2 Corner Installation: First review the necessary clearances specified below before considering where to position the heater along with the appliance dimensions in Section “8. Technical Drawings”. Also check the practicability of installing the flue system in relation to any obstructing roof beams before positioning the heater.
Tab bent in For example: Side wall clearance for the Nectre 15 LE is 750 mm. A 12mm gapped shield on the wall with a factor of 0.40. Tabs bent out Calculate:- 750 mm x 0.40 = 300 mm.
Page 5
Use the two ‘Z’ spacers supplied in the plastic If the draft is insufficient or periodic down drafting occurs packet in the heater to support the decro-mesh and and the heater smokes or only burns slowly, extending the inner shield up off the top of the heater. It is flue or fitting a specialist cowl will usually resolve the issue.
5. INSTALLING BAFFLE PLATE & FIRE BRICKS 6. TECHNICAL DRAWINGS 1) Remove the box of bricks from inside the heater. Legs Model: 2) Ensure that the 6mm steel baffle plate is orientated inside the firebox so that the 75mm fold is at the front and directed upwards.