Powering on the Dell Edge Gateway .......... 16 Mounting the Dell Edge Gateway on the wall ........19 Mounting the Dell Edge Gateway on a DIN rail ..21 Inserting a micro-SIM card and activating your mobile broadband ................23 Removing the micro-SIM card Setting up your operating system..........
Page 4
Setting up the Power Module ........... 46 Power module — Connecting a battery ...............48 Specifications - Power Module Enclosure Overview..............51 ......................51 Features ................. 53 Setting up the Enclosure ................60 Specifications - Enclosure Setting up the ZigBee Dongle ..........62 Contacting Dell................64...
The system can be either mounted on the wall using the Dell approved wall mount kit or mounted into your existing rack infrastructure using the DIN-rail mounting bracket. The system is running on Windows 10 Enterprise, Ubuntu Snappy, and Wind River Linux operating systems.
System Features Feature USB 2.0 port For USB 2.0 devices USB 2.0 port For USB 2.0 devices HDMI port Connect a Monitor or another HDMI‑in enabled device. Provides video and audio output. Wi-Fi antenna port (port four) Connect an antenna to increase the range and strength of the Wi-Fi signals.
Page 7
Feature Micro-SIM card slot Insert a micro-SIM card to connect to a mobile broadband network. Mobile broadband antenna Connect an antenna to increase the port (port one) range and strength of the mobile broadband signals. 10. Power module expansion port Connect an external power module for increased power options.
System LEDs Feature Serial port status LED Provide the status of the serial port connection. CANbus port status LED Provide the status of the CANbus port connection. RS422/485 port status LED Provide the status of the RS422/485 port connections. RS485 port status LED Provide the status of the RS485 port connections.
DIP switches Feature RS422/RS485 port toggle Toggle between RS422 or RS485 switch standard RS422/RS485 port resistor Enable/disable the differential switch termination resistor RS422/RS485 port bias Enable/disable the bias resistor for the resistor switch RS422/RS485 port RS422/RS485 port diagnostic Enable or disable the RS422/RS485 switch port RS485 port resistor switch...
WARNING: Always make sure that the available power source matches the required input power of the Dell Edge Gateway, check the input power markings next to power connector(s) before making connections. The 24 V power source must be compliant with local Electrical Codes and Regulations.
WARNING: When installing the Power Module, use a cable appropriate for the load currents: 3-core cable rated 15 A at 90 °C (194 °F) minimum, which conform to either IEC60227 or IEC 60245. The Gateway accepts cables of 14 AWG minimum. WARNING: Before installing that all of three power inputs (Terminal Block/Power Jack/Battery Input) in power module shall be protected by the 20 A fuses or circuit-breakers(over current protection device) in...
Instructions d'installation professionnelles Le personnel d'installation Ce produit est conçu pour des applications spécifiques et doit être installé par un personnel qualifié avec RF et connaissances connexes réglementaire. L'utilisateur ne doit pas tenter générale d'installer ou de modifier le réglage. Lieu d'installation Le produit doit être installé...
and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Page 14
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. This device complies with RSS-310 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference. Cet appareil est conforme à la norme RSS-310 d'Industrie Canada. L'opération est soumise à...
5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. Powering on the Dell Edge Gateway Install the Gateway on the wall mount using the Dell approved wall mounting kit.
RS422/R485 ports. Mounting the Dell Edge Gateway on the wall You can mount the Dell Edge Gateway on a wall by using mounting brackets. The brackets secure the Dell Edge Gateway to the wall. Secure the two mounting brackets to the rear of the Dell Edge Gateway...
Page 17
Drill four holes in the wall that correspond to the holes in the mounting bracket, then place the Dell Edge Gateway against the wall and align the holes in the mounting brackets with the holes in the wall.
Page 18
Tighten the screws to secure the Dell Edge Gateway to the wall.
Dell Edge Gateway. Align the screw holes on the DIN rail mount to the back of the Dell Edge Gateway, place the screws on the DIN rail mount and secure it to the Dell...
Page 20
Pull down on the tab to release the latch on the DIN rail mount. Mount the Dell Edge Gateway on a DIN rail.
Secure the Dell Edge Gateway by pressing the latch. Inserting a micro-SIM card and activating your mobile broadband CAUTION: It is recommended to insert the micro-SIM card before powering on the Dell Edge Gateway. Shutdown your system. Locate the micro-SIM card slot.
Page 22
Close the micro-SIM card tray. Power on your Gateway.
Connect to a Network NOTE: To activate your mobile broadband service, please contact the service provider with the following information: Windows OS Select the Network icon from the taskbar and then select Cellular. The Cellular page displays. Select your Mobile Broadband Carrier to expand the options. Select Advanced Options.
NOTE: For more information on setting up your Wind River operating system, see http://www.windriver.com/support. Power on the Gateway. The Wind River splash screen is displayed after the Dell Edge Gateway boots completes POST. The operating system will take around twenty seconds to complete the loading process.
• 64 GB SSD Dimensions Height 228.4 mm (8.99 inches) Width 216 mm (8.50 inches) Depth • Dell Edge Gateway 5000: 64.20 mm (2.52 inches) • Dell Edge Gateway 5100: 74.50 mm (2.93 inches) Memory Type LPDDR3 Speed 1600 MHz...
Page 26
Power adapter input voltage/current 19.5 VDC / 3.33A Environmental requirements Ingress Protection Rating IP50 Temperature range: Dell Edge Gateway 5000 Operating (with a maximum temperature gradation of 15°C • 0°C to 50°C (32°F to 122°F) when (59°F) per hour) connected to a 24V AC/DC power source.
Page 27
Environmental requirements • 0°C to 40°C (32°F to 104°F) when connected to a power adapter. NOTE: The maximum operating temperature is derated 1°C/ 305m (1000ft) above sea level altitude Non-operating (with a -40°C to 70°C (-40°F to 158 °F) maximum temperature gradation of 15°C (59°F) per hour) Relative humidity (maximum):...
The I/O module allows you to install a PCIe x1 card and adds additional ports to your Dell Edge Gateway. NOTE: The power module is required to be installed with the Dell Edge Gateway to enable and use the I/O expansion module.
Push both the top and bottom release- latch to disconnect the power module from the Dell Edge Gateway. I/O module expansion Connect the I/O module to the Dell connector and guide pin Edge Gateway. Power status light Indicates the power state of the I/O module and the Dell Edge Gateway.
Page 31
Remove the dust cap and loosen the access cover screw that secures the I/O Expansion Module to the cover, slide in the direction shown and carefully lift it off the module. Install the PCIe card on the PCIe expansion card slot on the I/O Expansion Module.
Page 32
Replace the cover on the I/O Expansion Module. NOTE: Replace the dust-caps on any unused ports and connectors. Tighten the screw that secures the cover to the I/O Expansion Module. Remove the dust-cap covering the I/O Module expansion port on the Dell Gateway connector.
Page 33
Align the I/O Module guide pin to port on the Dell Edge Gateway. Slide the I/O Module until it is fully seated into the Dell Edge Gateway.
Page 34
10 Lock the top and bottom latches to secure the module to the Dell Edge Gateway. 11 Install the Dell Edge Gateway and the I/O Module along with the Power Module at a desired location using wall-mount bracket or the DIN rail mount.
Power Module. NOTE: The power adapter and sealed lead-acid battery is sold separately. NOTE: The power module is required to be installed with the Dell Edge Gateway to enable and use the I/O expansion module. Specifications - I/O Module...
Page 36
Power requirements Phoenix connector input voltage/ 24 VAC (50 Hz–60 Hz) or 24 VDC / current Power adapter input voltage/current 19.5 VDC / 6.67A Battery connector port 12 VDC / 15A Environmental requirements Ingress Protection Rating IP50 NOTE: Enclosure meets IP50 with the pre-installed PCIe blank bracket.
Page 37
Environmental requirements Relative humidity (maximum): Operating (with maximum 10% to 90% (non-condensing) humidity gradation of 10% per hour) Non-operating ((with maximum 5% to 95% (non-condensing) humidity gradation of 10% per hour) Altitude (maximum, unpressurized): Operating -15.2m to 5000m (-50ft to 16,404ft) NOTE: The maximum operating temperature is derated 1°C/ 305m (1000ft) above sea level...
Page 38
System ambient Maximum Maximum Maximum after altitude supported power supported power supported power derating (°C) dissipation (W) dissipation (W) dissipation (W) for 85° C or for 70° C still air for 55°C still air above still air rated PCIe cards rated PCIe cards rated PCIe cards Not supported...
Power Module Overview The power module allows you to connect additional power sources to your Dell Edge Gateway. The power module allows you to connect to all three power sources, that is, the 24V AC/DC, 19.5 VDC, and a battery.
Features Feature Top release-latch Push both the top and bottom release- latch to disconnect the power module from the Dell Edge Gateway. Power status LED Indicates the power‑state of the power module and the Dell Edge Gateway.
Connect the power module to the Dell port Edge Gateway for increased power options and to power the I/O expansion module. Setting up the Power Module WARNING: Before installng the Power Module shutdown the Dell Edge Gateway and disconnect the power cable.
Page 42
NOTE: The power module is required to be connected with the Dell Edge Gateway to enable and use the I/O expansion module. Remove the dust-cap covering the Power Module expansion port on the Dell Gateway connector.
Page 43
Align the Power Module guide pins to the power module port on the Dell Edge Gateway and slide the Power Module until it is fully seated in the Dell Edge Gateway...
Page 44
Ensure the top and bottom latches are locked to secure the module to the Dell Edge Gateway...
Page 45
Install the Dell Edge Gateway and the Power Module at a desired location using wall-mount bracket or the DIN rail mount. Wall-mount bracket DIN rail...
Connect the power sources and press the power button on the Dell Edge Gateway. NOTE: You can connect the power cable to the 24V AC/DC, 19 VDC, and a battery simultaneously. NOTE: The power adapter and sealed lead-acid battery are sold separately.
Page 47
WARNING: Make sure the battery is installed in a secure location and follows all local fire codes and regulation. Read the safety instructions that is shipped with the battery. WARNING: Only a trained technician should setup/replace the battery. WARNING: Only install the battery inside an enclosure that meets fire safety requirements.
• Calculate the total length of wire from the battery to the system. • Determine current-carrying capacity in the wire. • Determine correct wire gauge in the intersection of amps and feet. Specifications - Power Module Dimensions Height 117.80 mm (4.64 inches) Width 216 mm (8.50 inches) Depth...
Page 49
Power requirements Terminal block connector input 24 VAC (50 Hz–60 Hz) or 24 VDC / voltage/current Power adapter input voltage/current 19.5 VDC / 6.67A Battery connector port 12VDC / 15A Environmental requirements Ingress Protection Rating IP50 Temperature range: Operating (with a maximum •...
Page 50
Environmental requirements Storage -15.20 m to 10,668 m (-50 ft to 35,000 ft)
Enclosure Overview The rugged enclosure allows you to install the Dell Edge Gateway in harsh environment’s, like locations that are subjected to high temperature variation, dust particle, and humidity. Features Feature Rugged Enclosure install the Dell Edge Gateway in the rugged enclosure when using in harsh environments condition.
Page 52
Feature door securing latch (3) secure the enclosure thermal ribs dissipates the heat generated by the system latch lock-out secure the system with a pad lock cable tie-off (17) to prevent accidental cable disconnection, tie all cables to the cable tie-off guides. cable conduit openings (8) route the cables through the conduits (1 inch and .75 inch diameter)
Setting up the Enclosure Install the Enclosure’s wall mount bracket at a desired location and secure it to the wall using the wall mount screws. NOTE: Ensure the notch on the bracket is on the top.
Page 54
Open the Enclosure. Place the Enclosure on the wall mount bracket and align the tab on the Enclosure to fit into the notch on the wall bracket.
Page 55
Place and tighten the screws with rubber washers to secure the Enclosure to the wall brackets. Align the screw holes on the wall mount brackets with the screw holes on the Dell Edge Gateway, place and tighten the screws to secure the wall mount brackets to the Gateway.
Page 56
Align the screw holes on the Dell Edge Gateway’s wall mount brackets with the screw holes on the Enclosure by positioning the Gateway onto the Enclosure’s two locator pins, place and tighten the screws to secure the Gateway to the enclosure...
Page 57
Connect the intrusion switch to the Gateway.
Page 58
Remove the desired conduits opening plugs on the bottom or the left side of the enclosure and install the wiring conduits. NOTE: To ensure that dust and water does not enter the enclosure install a conduit rated as IP65.
Page 59
Route your cables through the cable conduits on the bottom or the left side of the enclosure. NOTE: To reduce the risk of accidental cable disconnection, tie all cables to the cable tie-off guides.
10 Close and securely latch the Enclosure door. Specifications - Enclosure Dimensions Height 397 mm (15.62 inches) Width 443.40 mm (17.46 inches) Depth 79.80 mm (3.14 inches) NOTE: The dimensions do not include the latches and wall bracket on back of enclosure; the wall bracket adds 5 mm to the depth. Environmental requirements IP65 Ingress Protection Rating...
Page 61
Environmental requirements Operating (with a maximum • Dell Edge Gateway 5000: 0°C to temperature gradation of 15°C 45°C (32°F to 113°F) (59°F) per hour) • Dell Edge Gateway 5100: -30°C to 70°C (-22°F to 158°F) NOTE: The maximum operating temperature is derated 1°C/ 305m (1000ft) above sea level altitude.
NOTE: Do not connect the ZigBee dongle to the internal USB port of the I/O expansion module. Shut down your Dell Edge Gateway. Connect the ZigBee dongle to any external USB port on your Dell Edge Gateway. Connect the ZigBee dongle to any external USB port on the I/O module.
Page 63
Turn on the Dell Edge Gateway and complete setup. NOTE: For ZigBee development information go to SiLabs developer website at www.silabs.com/ or contact the system’s application provider.
Select the appropriate service or support link based on your requirement or choose the method of contacting Dell that is convenient for you. Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area.