APPLICATION
The H46C,E Humidity Controllers are used with portable
and central unit dehumidifiers to maintain relative
humidity. The H46 has an spst, snap-acting switch
designed for line voltage circuits. The H46C has two
leadwires for switch box mounting. The H46E has an
electric cord with an interrupter plug.
INSTALLATION
When Installing this Product...
1.
Read these instructions carefully. Failure to follow
them could damage the product or cause a hazard­
ous condition.
2.
Check the ratings given in the instructions and on
the product to make sure the product is suitable for
your application.
3.
Installer must be a trained, experienced service
technician.
4.
After installation is complete, check out product
operation as provided in these instructions.
A CAUTION
Electrical Shock Hazard.
Can cause electrical shock or equipment
damage.
Disconnect power supply before connecting
wiring.
Location
Select a location about 5 ft (1.5 m) above the floor in an
area with good circulation at average temperature and
humidity for the area to be controlled. Avoid locations
near hot or cold air ducts and discharge air from the
controlled equipment.
® U .S . R e g i s t e r e d T r a d e m a r k
C o p y r i g h t © 2 0 0 3 H o n e y w e l l I n t e r n a t i o n a l In c .
H46C,E Humidity Controllers
• All Rights Reserved
INSTALLATION INSTRUCTIONS
Mounting H46C
1.
Remove the setting knob.
2.
Pull the cover forward from the device to remove.
3.
Install a 2 in. x 3 in. (51 mm x 76 mm) vertical
switch box at the selected location.
4.
Using the two screws provided, fasten the adapter
plate to the switch box as shown. See Fig. 1.
5.
Pull the wires from the switch box through the
opening in the adapter plate and connect to the
H46 leadwires with the solderless connectors
(provided). See Fig. 4-6 for typical hookups.
6.
Push the wires back into the switch box.
7.
Place the H46 against the adapter plate, making
certain the tab at the bottom of the plate fits into the
notch on the H46.
8.
Fasten the H46 to the adapter plate by tightening
the captive screw.
9.
Replace the cover and the setting knob.
Mounting H46E
1.
At the selected location, insert the two wood
screws (provided) into the wall 2 in. (51 mm)
vertically apart and protruding 1/16 in. (2 mm) from
the wall. See Fig. 2.
2.
Position the H46 on the screws and slide it down
until the screws are in the slots.
3.
Insert the dehumidifier plug into the end of the
interrupter plug. See Fig. 3.
4.
Insert the interrupter plug into the electrical outlet.
NOTE: H46E has a 3-prong plug. When connecting to
the 2-prong receptacle, use the converter plug
(not included) and connect the pigtail lead to the
ground screw.
Honeywell
6 9 -1 0 0 0 B -1

Advertisement

loading

Summary of Contents for Honeywell H46E

  • Page 1 The H46C has two plate to the switch box as shown. See Fig. 1. leadwires for switch box mounting. The H46E has an Pull the wires from the switch box through the electric cord with an interrupter plug.
  • Page 2: Connections And Operation

    M7908 setting and control moisture using the dehumidistat. Fig. 2. Mounting H46E with two screws. H 46C ,E H U M ID IT Y C O N T R O LLE R...
  • Page 3 H46C,E HUMIDITY CONTROLLERS H 46C T87F/Q539A INTERNALSCHEMATIC HEATING RELAY OR VALVE COIL COOLING FAN RELAY PROVID E O VERLOAD PROTECTIO N AN D DISCONNECT MEANS CONTACTOR COIL COIL AS REQUIRED. H EATING DAMPER M OTOR, IF USED. CLOGGED FILTER SW ITCH OR COOLIN G PANEL CONNECTIO N. M7913 Fig.
  • Page 4: Settings And Adjustment

    ON position. Turn the knob counterclockwise to the motor stops. stop to place the H46 in the Off position. Honeywell Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422...
  • Page 5: Notice D'installation

    Insérer la fiche-prise dans la prise de courant. Risque de choc électrique. Peut causer des chocs électriques ou des NOTE: L’hygrostat H46E est muni d’une fiche à trois dommages matériels. broches. Pour le brancher sur une prise pour Couper l’alimentation avant d’effectuer le fiche à...
  • Page 6 MURAL propriétaire devrait régler le thermostat à un réglage relativement bas pour arriver à maîtriser l’humidité en se servant du déshumidistat. MF7908 D'ALIMENTATION Fig. 2. Montage du H46E au moyen des deux vis. HAUSSE HYGROSTAT D'HUMIDITÉ H46 C, E VENTILATEUR D'EXTRACTION .
  • Page 7 HYGROSTATS H46C,E H46C SCHÉMA INTERNE DE Q539A T87F Fig. 5. Schéma de câblage parallèle type du H46C et du T87F/Q539A pour assurer la déshumidification et empêcher le développement de moisissure. •1000B-1...
  • Page 8 H46 à la position Off. Honeywell Solutions de régulation et d'automatisation Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35, Dynamic Drive Golden Valley, MN 55422...

This manual is also suitable for:

H46c