hit counter script
Lenovo S3200 Product Manual
Hide thumbs Also See for S3200:

Advertisement

Lenovo Storage S3200
Lenovo Press Product Guide
The Lenovo® Storage S3200 (as shown in the following figure) is a versatile storage system that provides
simplicity, speed, scalability, security, and high availability for small to large businesses. The S3200 SAN
array delivers enterprise-class storage management technology in a cost-effective solution with a wide
choice of host connectivity options, flexible drive configurations, and enhanced data management
features.
The S3200 is a perfect fit for for a wide range of workloads, from specialized workloads (such as big data
and analytics, video surveillance, media streaming, and private clouds) to general purpose workloads
(such as file and print serving, web serving, email and collaboration, and OLTP databases). The S3200 is
also well-suited for secure archive storage or a consolidated backup solution.
Figure 1. Lenovo Storage S3200
The S3200 offers the flexible choice of storage connectivity protocols: 6/12 Gb SAS, 1 G,b or 10 Gb
iSCSI, and 4/8/16 Gb Fibre Channel (FC). The Converged Network Controller (CNC) design of the S3200
makes the selection of iSCSI or FC host connectivity (or both FC and iSCSI) as simple as attaching
corresponding transceivers or 10 GbE SFP+ Direct-Attach Copper (DAC) cables to the SFP/SFP+ ports
on the RAID controller.
The S3200 supports up to 192 drives with up to seven external expansion enclosures and it offers flexible
drive configurations with the choice of 2.5-inch and 3.5-inch drive form factors, 10 K or 15 K rpm SAS and
7.2K rpm NL SAS hard disk drives (HDDs) and self-encrypting drives (SEDs), and SAS solid-state drives
(SSDs). The S3200 can be scaled up to 576 TB of raw storage capacity.
Did you know?
The S3200 supports Intelligent Real-time Tiering capabilities that help optimize system performance,
reduce costs, and simplify management. The base software includes the ability to move data dynamically
between SAS HDDs that are optimized for cost per IOPS and NL SAS HDDs that are optimized for cost
per GB. With the optional software license, the S3200 supports hybrid tiering across HDDs and SSDs.
With flexibility of the Converged Network Controllers, the S3200 supports hybrid iSCSI and Fibre Channel
connectivity at the same time.
The S3200 supports battery-free cache protection, which reduces maintenance costs and provides
permanent backup of unwritten cache data if there is a power failure.
Lenovo Storage S3200
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo S3200

  • Page 1 The S3200 is a perfect fit for for a wide range of workloads, from specialized workloads (such as big data and analytics, video surveillance, media streaming, and private clouds) to general purpose workloads (such as file and print serving, web serving, email and collaboration, and OLTP databases).
  • Page 2: Key Features

    Lenovo Storage E1012 expansion enclosure (12x LFF drives each) or up to 192 SFF drives per system with the attachment of Lenovo Storage E1024 expansion enclosure (24x SFF drives each) to satisfy growing needs for storage capacity and performance.
  • Page 3 The S3200 storage system offers high levels of system and data availability with the following technologies: Dual-active RAID controllers with low latency cache mirroring  Dual-port drives (HDDs and SSDs) with automatic drive failure detection and rapid RAID rebuild with ...
  • Page 4 The S3200 storage capabilities can be expanded with optional licensed functions. Each optional S3200 function is licensed on a per-system basis and covers controller enclosure and all attached expansion units. The following optional licensed functions are available: Intelligent Real-time Tiering for SSDs ...
  • Page 5 Components The following figure shows the front of the S3200 SFF chassis and E1024 drive expansion enclosure. Figure 2. Front view of the S3200 SFF chassis and E1024 drive enclosure The following figure shows the front of the S3200 LFF chassis and E1012 drive expansion enclosure.
  • Page 6 The following figure shows the rear of the S3200 with FC or iSCSI host interfaces with dual RAID controllers. Single RAID controller configurations also are supported. Figure 4. Rear view of the S3200 with FC or iSCSI host interfaces The following figure shows the rear of the S3200 with SAS host interfaces with dual RAID controllers.
  • Page 7: Technical Specifications

    The following figure shows the rear of the E1012 and E1024 drive enclosures with dual I/O expansion modules. Single I/O module configurations also are supported with the single-controller S3200. Figure 6. Rear view of the E1012 and E1024 drive enclosures Note: The RAID controllers (as shown in Figure 4 and Figure 5) and expansion modules (as shown in Figure 6) have extra service ports with a specialized connector.
  • Page 8 Host connectivity S3200 SAS controller: 4x 6/12 Gb SAS host ports (Mini-SAS HD, SFF-8644) S3200 FC and iSCSI controller: 4x SFP/SFP+ host ports with two built-in dual-port CNCs (each port on the same CNC must have the same connectivity type, different CNCs might have...
  • Page 9: Controller Enclosures

    4-hour response time, 1-year or 2-year warranty extensions, Hard Drive Retention. Dimensions S3200 LFF and E1012: Height: 87 mm (3.4 in), width: 447 mm (17.6 in), depth: 523 mm  (20.6 in) S3200 SFF and E1024: Height: 89 mm (3.5 in), width: 447 mm (17.6 in), depth: 519 mm ...
  • Page 10: Raid Controller Modules

     S3200 SAS RAID Controllers provide direct SAS attachment for up to four hosts with a supported SAS HBA that is installed in the host. Each S3200 SAS Controller has four 6/12 Gb SAS ports with Mini-SAS HD (SFF-8644) connectors.
  • Page 11 FC and iSCSI controller host connectivity options Lenovo Storage S2200/S3200 1G RJ45 iSCSI SFP+ Module 1 pack 00WC086 AT2C Lenovo Storage S2200/S3200 10G SW Optical iSCSI SFP+ Module 1 pack 00WC087 AT2A Lenovo Storage S2200/S3200 8G Fibre Channel SFP+ Module 1 pack 00WC088 AT28...
  • Page 12: Expansion Enclosures

    Each expansion module has two 6 Gb SAS x4 ports (Mini-SAS SFF-8088 connectors) that are labelled IN and OUT. These ports are used for connections to the S3200 and for daisy chaining the E1012 and E1024 enclosures between each other. The expansion port on the S3200 controller is connected to the IN port on the expansion module.
  • Page 13 The expansion connectivity topology for dual controller configurations is shown in the following figure. For single controller configurations, only Controller A path is present. Figure 7. Expansion connectivity topology Lenovo Storage S3200...
  • Page 14: Drive Options

    * One cable per SAS expansion module Drive options The S3200 LFF chassis and the E1012 expansion enclosure support up to 12 LFF hot-swap drives. The S3200 SFF chassis and the E1024 expansion enclosure support up to 24 SFF hot-swap drives.
  • Page 15: Software Options

    The following table lists drive options for the S3200 SFF chassis and the E1024 expansion enclosure. Table 7. LFF drive options Feature code Maximum (MTM qty per one Part 6411-HC2, S3200 SFF number 6411-HC3) or E1024 Description 2.5-inch SAS hot-swap HDDs Lenovo Storage 2.5"...
  • Page 16: Power Cables

    AT2J Power cables The S3200, E1012, and E1024 ship standard with two 4.3 m, 10 A/100 - 250 V, C13 to IEC 320-C14 Rack Power Cables. Other power cable options are also available. The part numbers and feature codes to order the power cables (two power cables are required per each S3200, E1012, and E1024) are listed in the following table.
  • Page 17: Operating Environment

    Operating: 8% - 85% (non-condensing)  Storage: 5% - 90% (non-condensing)  Electrical: 100 - 240 (nominal) V AC; 50 Hz - 60 Hz  BTU output: 1488 Btu/hr (436 W)  Noise level: 6.8 bels  Lenovo Storage S3200...
  • Page 18: Warranty Options

    Lenovo system. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands.
  • Page 19: Regulatory Compliance

    Lenovo provides end-to-end storage compatibility testing to deliver interoperability throughout the network. The S3200 supports attachment to Lenovo System x®,ThinkServer®, and Flex System™ hosts by using SAS, iSCSI, FC, or FC over Ethernet (FCoE) (via the FCoE gateway) storage connectivity protocols.
  • Page 20 The S3200 supports iSCSI attachments via standard 1 Gb or 10 Gb Ethernet network. Any compatible Ethernet switch, including Lenovo RackSwitch™ top of rack (TOR) switches and integrated Flex System Ethernet I/O modules, can be used to provide iSCSI connectivity with the S3200 iSCSI storage.
  • Page 21 Table 12. S3200 FC adapter interoperability (Part 2) Description Part number System x servers - 8 Gb FC Brocade 8Gb FC Dual-port HBA 46M6050 Brocade 8Gb FC Single-port HBA 46M6049 Emulex 8Gb FC Dual-port HBA 42D0494 Emulex 8Gb FC Single-port HBA...
  • Page 22 Lenovo support web site (http://support.lenovo.com) or ask a Lenovo representative. Networking switches The following table lists the Ethernet and Fibre Channel rack mount switches that are offered by Lenovo that can be used in S3200 storage solutions. Table 13. Ethernet and Fibre Channel rack mount switches...
  • Page 23 Cisco Nexus B22 Fabric Extender with FET bundle for Flex System* 94Y5355 Converged 10 GbE and 8 Gb FC (FCoE gateways) Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch 00FM510 Converged 10 GbE and 16 Gb FC (FCoE gateways)
  • Page 24: Rack Cabinets

    Rack cabinets The following table lists the rack cabinets that are offered by Lenovo that can be used in S3200 storage solutions. Table 15. Rack cabinets Description Part number 11U Office Enablement Kit 201886X 25U Standard Rack 93072RX 25U Static S2 Standard Rack...
  • Page 25: Power Distribution Units

    Power distribution units The following table lists the the power distribution units (PDUs) that are offered by Lenovo that can be used in S3200 storage solutions. Table 16. Power distribution units (Part 1) Description Part number Switched and Monitored PDUs...
  • Page 26 0U 12 C19/12 C13 60A 3 Phase PDU 46M4140 0U 12 C19/12 C13 32A 3 Phase PDU 46M4143 For more information, see the list of Product Guides in the Power infrastructure category that is available at this website: http://lenovopress.com/systemx/power Lenovo Storage S3200...
  • Page 27: Uninterruptible Power Supply Units

    Uninterruptible power supply units The following table list the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in S3200 storage solutions. Table 17. Uninterruptible power supply units Description Part number RT1.5kVA 2U Rack or Tower UPS (100-125VAC) 55941AX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
  • Page 28: Lenovo Financial Services

    For you, this dedication provides a high-quality, easy, and positive financing experience. For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website: http://www.lenovo.com/services_warranty/us/en/financial_services.html...
  • Page 29 Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment.
  • Page 30 Trademarks Lenovo, For Those Who Do and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. These and other Lenovo trademarked terms are marked on their first occurrence in this information with the appropriate symbol (® or ™), indicating US registered or common law trademarks owned by Lenovo at the time this information was published.

Table of Contents