1) Introduction
The BExCL150-05D is a flameproof combined loudspeaker /
beacon which is certified to meet the requirements of the
ATEX directive 94/9/EC and the IECEx Scheme. The
loudspeaker section produces a 15 watt audio signal and the
beacon section produces a synchronised visual warning
signal. There are three loudspeaker section versions, 8 ohm,
16 ohm or 100V Line transformer. On 100V line transformer
units there are four output tappings and the unit produces
output levels in the 112dB(A) range. The unit can be used in
hazardous areas where potentially flammable atmospheres
may be present. The unit can be used in Zone 1 and Zone 2
areas with gases in groups IIA and IIB and with Temperature
Classifications of T1, T2, T3 and T4.
2) Marking
All units have a rating label, which carries the following
important information:-
BExCL15-05D
Unit Type No.
Loudspeaker
8 ohm or 16 ohm
Impedance:
100V Line
Beacon Input
DC Units
Voltage:
AC Units
Ex d IIB T4 for T
Code:
KEMA 01ATEX2223X
Certificate No.
IECEx KEM 10.0025X
Epsilon x:
Equipment Group
and Category:
CE Marking:
Notified Body No.
"Warnings"
DO NOT OPEN WHEN AN EXPLOSIVE
GAS ATMOSPHERE IS PRESENT
COVER BOLTS CLASS A4-80
USE HEAT RESISTING CABLES AND
CABLEGLANDS (Rated 110ºC) AT
AMB. TEMPERATURES OVER 40ºC
Year of Construction /
Serial No.
3)
Type Approval Standards
The units have an EC Type examination certificate issued by
KEMA and have been approved to the following standards:-
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. IS 2442-P
INSTRUCTION MANUAL (ATEX / IECEx)
Flameproof Combined Loudspeaker / Beacon
12V or 24V or 48V
230V or 115V
°
°
–50
C to +70
C
a
II 2G
0518
i.e. 10 / 1CL21000001
Issue E
23-04-10
BExCL15-05D
EN60079-0:2006 IEC60079-0:2004 (Ed4)
EN60079-1:2007 IEC60079-1:2007 (Ed6)
4)
Installation Requirements
The unit must be installed in accordance with the latest
issues of the relevant parts of the EN60079 specifications or
the equivalent IEC specifications – Selection, Installation and
maintenance of electrical apparatus for use in potentially
explosive atmospheres (other than mining applications or
explosive processing and manufacture):-
EN60079-14:2008
IEC60079-14:2007 (Ed4)
EN60079-10:2003
IEC60079-10:2008 (Ed1)
The installation of the unit must also be in accordance with
any local codes that may apply and should only be carried
out by a competent electrical engineer who has the
necessary training.
5)
Zones, Gas Group, Category and Temperature
Classification
The BExCL15-05D unit has been certified Ex d IIB T4 for Ta
–50ºC to +70ºC. This means that the units can be installed in
locations with the following conditions:-
Area Classification:
Zone 1
Zone 2
Gas Groupings:
Equipment Category:
Temperature Classification:
Ambient Temperature Range:
Sheet 1 of 5
Electrical Installations in Hazardous
Areas (other than mines)
Classification of Hazardous Areas
Explosive gas air mixture likely to occur in
normal operation.
Explosive gas air mixture not likely to occur,
and if it does, it will only exist for a short time.
Group IIA
Propane
Group IIB
Ethylene
2G
o
T1
400
C
o
T2
300
C
o
T3
200
C
o
T4
135
C
-50°C to +70°C
sales@e-2-s.com
Tel: +44 (0)208 743 8880
www.e-2-s.com
Fax: +44 (0)208 740 4200
General Requirements
Flameproof Enclosure 'd'