Operating Instructions (Compact) SIMATIC Industrial PC SIMATIC Panel PC 677 Operating Instructions (Compact) Edition 07/2006 A5E00877730-01...
Page 2
Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Warning Make sure that a damaged device is not installed nor put into operation. 8. Note the identification information as described in the chapter "Identification data of the device". SIMATIC Panel PC 677 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Ethernet addresses: BIOS Setup (F2 Key) under Main > Hardware Options > Ethernet Address Product Documentation The detailed operating instructions for Panel PC 677 can be downloaded as a PDF file on the Internet under the following address: http://www.ad.siemens.com Safety instructions...
Permitted mounting positions Mounting Positions Only vertical installation with a deviation of up to +20° and -20° in the specified directions is permitted for the device. Figure 1-1 Permitted mounting positions SIMATIC Panel PC 677 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
120 in the seal area Setscrews Seal area Note Installed dimensions can be read from the dimension overview or they can be transferred to the cabinet from the mounting template supplied. SIMATIC Panel PC 677 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Page 7
Otherwise the mounting cut-out is useless. Complete the mounting cut-out in accordance with the dimensions SIMATIC Panel PC 677 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
124 mm Touch panel with 19" 130 mm Note Additional mounting depth with optical drive The installation depth increases by 21 mm when an optical drive is installed in the device. SIMATIC Panel PC 677 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Secure the control unit in the mounting cut-out from behind with the clamps, as shown in the mounting cut-out in the dimensions. Tighten the setscrews to a torque of 0.4-0.5 Nm SIMATIC Panel PC 677 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Page 10
1. The material strength at the mounting cut-out must be at least 2 mm. 2. The deviation from the plane in relation to the external dimensions for an installed HMI device is ≤ 0.5 mm. SIMATIC Panel PC 677 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Deburr the holes from the front of the control unit Notice Risk of Damage Ensure that no metal cuttings enter the device when the holes are drilled. Cover the device with film or when drilling, use removal by suction. SIMATIC Panel PC 677 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Page 12
Carefully drill the respective holes in the control unit at the designated location from the rear Working from the front, insert the device into the mounting cut-out Secure the control unit by inserting suitable screws through the holes and attaching nuts SIMATIC Panel PC 677 1-10 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Page 13
1. The material strength at the mounting cut-out must be at least 2 mm. 2. The deviation from the plane in relation to the external dimensions for an installed HMI device is ≤ 0.5 mm SIMATIC Panel PC 677 1-11 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
The On / Off switch does not disconnect the device from mains. When the switch is in the 0 position, the device is still connected to the auxiliary voltage. SIMATIC Panel PC 677 1-12 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Page 15
• Peripherals are developed and marketed by individual vendors. The respective manufacturers offer support for the peripherals. Moreover, the terms of liability of the individual vendors or suppliers apply here. SIMATIC Panel PC 677 1-13 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Always ensure free and easy access to the power inlet on the device or that the safety power outlet of the building installation is freely accessible and located close to the device. SIMATIC Panel PC 677 1-14 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Depending on the size of the display and taking into account 15 W per PCI slot, the power consumption for devices with 12" and 15" operator control units is max. 140 W, and with 19" operator control units it is max. 163 W. SIMATIC Panel PC 677 1-15 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Page 18
24 V power supply Switch off the 24 V DC power supply Connect the DC connector (1) 24 V DC (2) ground (3) protective conductor SIMATIC Panel PC 677 1-16 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Connect the equipotential bonding connection (M4 thread) (1) on the device (large surface, large-area contact) with the central grounding point of the control cabinet. The minimum permissible cross-section is 5 mm SIMATIC Panel PC 677 1-17 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
The device may not be switched off at any time during the installation process. Do not change the default BIOS settings, otherwise the operating system setup may become corrupted. SIMATIC Panel PC 677 1-18 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Page 21
To prevent data loss, it is advisable to create an image of your system partition after initial commissioning. Switching Off the Device. When you work with Windows 2000 / Windows XP Professional, always shut down the PC with the command Start > Turn Off Computer. SIMATIC Panel PC 677 1-19 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
1. In the "Panel Wizard" dialog, click the type of panel that corresponds to your device. Figure 1-5 Panel Wizard, selection of the panel type 2. Follow the instructions on the screen. SIMATIC Panel PC 677 1-20 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Page 23
F11 to F20 and S1 to S16 are used or if own key code tables are used. SIMATIC Panel PC 677 1-21 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
Calling up TouchInput Call up the "TouchInput" application on the desktop. The screen keyboard is displayed. Key for selecting the keyboard layouts for specific countries: German, English, Italian, Spanish, French SIMATIC Panel PC 677 1-22 Operating Instructions (Compact), Edition 07/2006, A5E00877730-01...
The online catalog and the online ordering system is available at: http://mall.automation.siemens.com/ Training center Siemens offers a number of training courses to familiarize you with the SIMATIC automation system. Please contact your regional Training Center, or the central Training Center in D90327 Nuremberg.
Page 26
• A forum is available for users and specialists from all over the world to exchange experiences • Your local Siemens partner for Automation & Drives in our partner database • Information about on-site service, repairs, spare parts. Lots more is available under ”Services”...