Page 1
CDP-XE530 3 7 63 1515 0 SERVICE MANUAL AEP Model UK Model Photo : SILVER Model Name Using Similar Mechanism CD Mechanism Type CDM14FL-5BD25 Base Unit Type BU-5BD25 Optical Pick-up Type KSS-213BA/F-NP SPECIFICATIONS L 13942296513 Compact Disc Player General Laser Semiconductor laser (λ...
COMPONENTS IDENTIFIED BY MARK ! OR DOTTED LINE WITH MARK ! ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY.
http://www.xiaoyu163.com SECTION 1 SERVICING NOTE 3 7 63 1515 0 HOW TO OPEN THE DISC TRAY WHEN POWER SWITCH NOTES ON HANDLING THE OPTICAL PICK-UP BLOCK TURNS OFF OR BASE UNIT Insert a tapering driver into the aperture of the unit bottom, and turn The laser diode in the optical pick-up block may suffer in the direction of arrow.
Page 4
http://www.xiaoyu163.com 3 7 63 1515 0 CD-TEXT TEST DISC This unit is able to display the TEXT data (character information) written in the CD on its fluorescent indicator tube. The CD-TEXT TEST DISC (TGCS-313: J-2501-126-A) is used for checking the display. To check, perform the following procedure.
Page 5
http://www.xiaoyu163.com 3 7 63 1515 0 Table 2: CD-TEXT TEST DISC Recorded Contents and Display (In this unit, some special characters cannot be displayed. This is not a fault.) TRACK Recorded contents Display ···· ! ” # $ % & are not displayed ! ”...
http://www.xiaoyu163.com SECTION 3 DISASSEMBLY 3 7 63 1515 0 Note : Follow the disassembly procedure in the numerical order given. 3-1. FRONT PANEL • In order to remove the front panel block when the power supply does not turn on, rotate the cam with tapering driver as the figure shows, and the loading part will be moved.
http://www.xiaoyu163.com SECTION 4 TEST MODE 3 7 63 1515 0 4-1. AF MODE Button No. Button No. Button Button The following checks can be performed in the AF mode, which is Displayed Displayed set by connecting the JW617 (AFADJ) terminal on MAIN LANGUAGE board to the Ground and turning on the power.
Page 9
http://www.xiaoyu163.com 3 7 63 1515 0 4-3. AGING MODE [ MAIN BOARD ] – Component Side – This unit is equipped with an aging mode to check operations of the mechanism deck. • When faults occur: Aging stops, and the state when aging stopped is displayed on the fluorescent display tube.
http://www.xiaoyu163.com SECTION 5 ELECTRICAL BLOCK CHECKING 3 7 63 1515 0 Note: CD Block is basically designed to operate without adjustment. symmetry Therefore, check each item in order given. S-curve waveform Use YEDS-18 disc (3-702-101-01) unless otherwise indicated. Use an oscilloscope with more than 10MΩ impedance. Clean the object lens by an applicator with neutral detergent Within 3.8 ±...
Page 11
http://www.xiaoyu163.com 3 7 63 1515 0 Adjustment Location : 1 track jump waveform Center of the waveform [ MAIN BOARD ] – Component Side – A (DC voltage) + 0.7 CN621 level : 1.3 Vp-p symmetry – 0.6 E-F Balance Check (With general remote commander) oscilloscope BD board JW613 (ADJ)
Page 21
http://www.xiaoyu163.com 3 7 63 1515 0 • IC501 SYSTEM CONTROL (CXP82832-012Q)(DISPLAY board) Pin No. Pin Name Function FL grid signal output FL grid signal output – Connected to VDD – Power supply (+5V) SCOR Sub code sync input 6, 7 –...
Page 22
http://www.xiaoyu163.com 3 7 63 1515 0 Pin No. Pin Name Function – Ground – Not used – Connected to ground VDD (+5V) – Power supply (+5V) VFDP (–30V) – Pull down voltage (–30V) XSEL Not used — – Not used LP CONTROL LP control hold output 49 to 66...
Page 24
http://www.xiaoyu163.com 3 7 63 1515 0 IC102 BA6392FP BUFF CH1 OUT F 28 GND BUFF BUFF CH1 OUT R 27 CH4 OUT F LEVEL SHIFT CAPA IN 1 26 CH4 OUT R BUFF CH1 R IN 25 VB IN INTERFACE CH1 F IN 24 VS IN BUFF...
http://www.xiaoyu163.com 3 7 63 1515 0 • MAIN SECTION IC631 LB1641 IC601 LA5602 T.S.D O.C.P V IN MOTOR MOTOR ERROR DRIVE DRIVE REFERENCE VOLTAGE OVER CURRENT LIMITTER FWD/REV/STOP OVER HEAT CONTROL LOGIC PROTECTION ON/OFF RESET CDEL V OUT IC661 CXD8567AM L 13942296513 INIT D Vdd 2...
Page 26
http://www.xiaoyu163.com SECTION 7 EXPLODED VIEWS 3 7 63 1515 0 NOTE: • -XX, -X mean standardized parts, so they may • The mechanical parts with no reference number • Color Indication of Appearance Parts have some differences from the original one. in the exploded views are not supplied.
http://www.xiaoyu163.com SECTION 8 ELECTRICAL PARTS LIST 3 7 63 1515 0 NOTE: • Due to standardization, replacements in the • CAPACITORS: • SEMICONDUCTORS parts list may be different from the parts uF: µF In each case, u: µ, for example: specified in the diagrams or the components •...