Thinkpad edge series topseller notebooks & desktop, usb 3.0 secure 1tb hard drive, 90w ultraslim ac/dc combo adapter, ultraslim plus wireless keyboard and mouse, essential notebook stand, thinkpad mini dock plus series 3 with usb 3.0 - 90w (248 pages)
Les sikkerhetsinformasjonen (Safety Information) før du installerer dette produktet. Antes de instalar este produto, leia as Informações sobre Segurança. Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. Bu ürünü kurmadan önce güvenlik bilgilerini okuyun. Guidelines for trained service technicians This section contains information for trained service technicians.
you identify an unsafe condition, you must determine how serious the hazard is and whether you must correct the problem before you work on the product. Consider the following conditions and the safety hazards that they present: v Electrical hazards, especially primary power. Primary voltage on the frame can cause serious or fatal electrical shock.
v Before you work on the equipment, disconnect the power cord. If you cannot disconnect the power cord, have the customer power-off the wall box that supplies power to the equipment and lock the wall box in the off position. v Never assume that power has been disconnected from a circuit.
Page 11
Statement 1 DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm. v Connect all power cords to a properly wired and grounded electrical outlet. v Connect to properly wired outlets any equipment that will be attached to this product.
Page 12
Statement 2 CAUTION: When replacing the lithium battery, use only Part Number 33F8354 or an equivalent type battery recommended by the manufacturer. If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer.
You can obtain up-to-date information about the compute node at http://www.ibm.com/systems. The compute node might have features that are not described in the documentation that comes with the compute node. The documentation might be updated occasionally to include information about those features. Technical updates might also be available to provide additional information that is not included in the compute node documentation.
Safety Information document. v Lenovo Warranty Information This printed document contains the warranty terms and a pointer to the Lenovo Statement of Limited Warranty. v Environmental Notices and User Guide This document is in PDF.
use in your system and displays the documents in the language for that region (if available). If a document is not available in the language for that region, the English-language version is displayed. Use one of the following procedures to start the Documentation Browser: v If Autostart is enabled, insert the CD into the CD or DVD drive.
v Caution: These statements indicate situations that can be potentially hazardous to you. A caution statement is placed just before the description of a potentially hazardous procedure step or situation. v Danger: These statements indicate situations that can be potentially lethal or hazardous to you.
Page 18
Drives: v Support for up to two 2.5-inch hot-swap, small form factor (SFF) Serial Attached SCSI (SAS) or Serial ATA (SATA) hard disk drives, or up to two 2.5-inch hot-swap solid state drives (SSDs) v Optional support for up to four 1.8-inch hot-swap SSDs v Optional RAID controller supports up to four 1.8-inch hot-swap SSDs and up to four non-hot-swap 1.8-inch SSDs Flash DIMMs:...
– Relative humidity: 5% - 100% – Maximum dew point: 29°C (84.2°F) v Particulate contamination Attention: Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the compute node. For information about the limits for particulates and gases, see “Particulate contamination”...
Page 20
For more information, see “Using the ServerGuide Setup and Installation CD” on page 46. v Lenovo X-Architecture Lenovo X-Architecture systems combine proven, innovative designs to make your x86-processor-based compute node powerful, scalable, and reliable. For more information, see http://www.ibm.com/systems/x/hardware/enterprise/.
Page 21
– Web browser For more information, see Chapter 4, “Accessing the IMM2,” on page 49. v Large system-memory capacity The compute node supports up to 3 TB of system memory. The memory controllers provide support for up to 48 industry-standard registered ECC DDR3 on low-profile (LP) DIMMs on the system board.
Command-Line Interface Reference Guide at http://pic.dhe.ibm.com/ infocenter/flexsys/information/topic/com.ibm.acc.cmm.doc/ dw1kt_cmm_cli_book.pdf. – Flex System Manager management software is a platform-management foundation that streamlines the way you manage physical and virtual systems in a heterogeneous environment. By using industry standards, Flex System Manager management software supports multiple operating systems and virtualization technologies.
Cover Left air baffle Right air baffle Heat sinks Hard disk drive cage and backplane assembly Hot-swap I/O expansion hard disk adapter drive DIMM Center Microprocessor partition Hard disk drive filler panel Left Right filler bezel bezel Power, controls, and indicators Use this information to view power features, turn on and turn off the compute node, and view the functions of the controls and indicators.
Page 24
Hard disk drive status LED (yellow) When this yellow LED is lit, it indicates that an error has occurred with the hard disk drive. The LED turns off only after the error is corrected. You can check the CMM event log to determine the source of the condition. For more information, see “Viewing event logs without restarting the compute node”...
Page 25
v From the CMM web interface, select Compute Nodes from the Chassis Management menu. All fields and options are described in the CMM web interface online help. For more information, see http://pic.dhe.ibm.com/infocenter/flexsys/information/index.jsp?topic= %2Fcom.ibm.acc.cmm.doc%2Fcmm_product_page.html. v For more information about Flex System Manager management software, see the "Flex System Manager Software: Installation and Service Guide"...
Page 26
Reference Guide" at http://pic.dhe.ibm.com/infocenter/flexsys/ information/topic/com.ibm.acc.cmm.doc/cli_command_power.html. v From the CMM web interface, select Compute Nodes from the Chassis Management menu. For more information, see the "Flex System Chassis Management Module: User's Guide" at http://pic.dhe.ibm.com/ infocenter/flexsys/information/topic/com.ibm.acc.cmm.doc/ cmm_user_guide.html. All fields and options are described in the CMM web interface online help.
Console breakout cable Use this information for details about the console breakout cable. Attention: Use only the console breakout cable that comes with the compute node. Attempting to connect other console breakout cable types might damage the console breakout cable and the compute node. Use the console breakout cable to connect external I/O devices to the compute node.
1. Wait until the power LED on the compute node flashes slowly before you press the power button. While the IMM2 in the compute node is initializing and synchronizing with the Chassis Management Module, the power LED flashes rapidly, and the power button on the compute node does not respond.
such as a remote request to turn on the compute node. To remove all power from the compute node, you must remove it from the Flex System chassis. Before you turn off the compute node, shut down the operating system. See the operating-system documentation for information about shutting down the operating system.
DIMMs DIMMs DIMMs DIMMs expansion backplane 1 Fabric 1 (some models) expansion Micro- processor expansion Micro- processor Fabric 2 (some CMOS models) battery backplane 2 Ligthpath diagnostic Internal panel DIMMs DIMMs DIMMs DIMMs expansion USBs System-board jumpers Use this information to locate the system-board jumpers. The following illustration shows the locations of the jumpers on the system board.
Jumper number Description IMM TPM (JP2461) Two-pin jumper. The default is no jumper. Place a jumper on pins 1 and 2 to indicate a physical presence to the IMM2 TPM chip. Low Security (J2101) Three-pin jumper block. The default position is pins 2 and 3. Power permission (JP9601) Two-pin jumper block.
Page 32
On Off On Off SW8111 SW8110 switch switch The following table describes the functions of the switches. Switch number Description Switch setting Definition SW8110-1 Password override The default position is Changing this switch off. to the on position overrides the power-on password.
Page 33
Switch number Description Switch setting Definition SW8110-4 Boot backup IMM2 The default position is When the switch is in off. the default off position, the compute node will boot by using the primary IMM2 firmware. When the switch is in the on position, the compute node will boot by using a backup of the...
Switch number Description Switch setting Definition SW8111-2 IMMv2 Reset The default position is Changing this switch off. to the on position forces the compute node to reset the IMM. SW8111-3 ME Flash descriptor The default position is Changing this switch security override off.
– One partition containing two compute nodes and two partitions each containing one compute node v Stand-alone mode: The compute nodes operate independently within a multi-node complex. Each compute node uses its own UEFI settings. To partition a multi-node complex, use the IMM2 Web interface (see “Partitioning a multi-node complex”...
Page 36
Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259: Installation and Service Guide...
For more information, see Chapter 4, “Accessing the IMM2,” on page 49. Updating firmware and device drivers Lenovo periodically makes UEFI code, IMM2 firmware, diagnostic firmware updates, and device driver updates available for the compute node. Provisioning is the set of actions that you take to update the firmware and device drivers and install the operating system.
Page 38
3. If you are using a compute node that came with the Ethernet LAN-on-motherboard (LOM) controller integrated on the system board, you can find the device drivers at http://www.emulex.com/downloads/ibm/vfa- software-kits.html. 4. Follow the instructions in the readme file that comes with the firmware update. v Flex System Manager Update Manager Flex System Manager Update Manager (if installed) acquires, installs, and manages firmware and device driver updates and monitors your compute nodes...
You can use IMM2 to update some types of compute node firmware. For more information about the IMM2, see http://www.ibm.com/support/entry/portal/ docdisplay?lndocid=MIGR-5086346. Important: To avoid problems and to maintain system performance, always make sure that the UEFI code, IMM2 firmware, and diagnostic firmware levels are consistent in all compute nodes in the Flex System chassis.
Note: If the check log LED is lit, the compute node is booting from the backup image and moving the switch to backup changes nothing. 1. Before you begin, read “Safety” on page v and “Installation guidelines” on page 699. 2.
2. Set the boot protocol by using the Setup utility (see “Setting the boot protocol to boot from legacy devices using the Setup utility” on page 35). You can temporarily redefine the boot order by using the Boot Selection menu program (see “Using the Boot Selection Menu program”...
Page 42
http://pic.dhe.ibm.com/infocenter/flexsys/information/topic/ com.ibm.acc.cmm.doc/cmm_user_guide.html. All fields and options are described in the CMM web interface online help. Note: The integrated management module II (IMM2) must have a valid IP address. To start the Setup utility locally, complete the following steps: 1. If the compute node is turned on, turn off the compute node (see “Turning off the compute node”...
Page 43
Select this choice to view information about the adapters and UEFI device drivers in the compute node. Note: Before you configure a UEFI-compatible device, update the firmware for your compute node. See “Updating firmware and device drivers” on page 25 for information about how to update the firmware for your compute node. To configure a UEFI-compatible expansion adapter, complete the following steps: 1.
Page 44
- Reset IMM to Defaults Select this choice to restore the IMM2 to the manufacturing default settings. The IMM2 controller restarts after you restore the settings. - Reset IMM Select this choice to restart the IMM2 controller. – Legacy Support Select this choice to view or set legacy support.
Page 45
Select this choice to enable advanced RAS options. - Backup Bank Management Select this choice to configure the backup bank management settings. - Disk GPT Recovery Select this choice to enable or disable GUID partition table (GPT) drive recovery. - POST Attempts Select this choice to define the number of times to attempt POST before invoking the recovery procedures.
Page 46
v Boot Manager Select this choice to view, add, delete, or change the device boot priority, boot from a file, select a one-time boot, or reset the boot order to the default setting. Select Boot Modes to view or change the boot settings. You can set the boot mode and choose UEFI operating-system support only, or legacy operating-system support only.
Important: Removing the CMOS battery clears the settings in CMOS memory. v Save Settings Select this choice to save the changes that you have made in the settings. v Restore Settings Select this choice to cancel the changes that you have made in the settings and restore the previous settings.
3. When the prompt Press <F1> Setup is displayed, press F1. If you have set an administrator password, you must type the administrator password to access the full Setup utility menu. If you do not type the administrator password, a limited Setup utility menu is available.
Results The next time the compute node starts, it returns to the startup sequence that is set in the Setup utility. Updating the Universally Unique Identifier and DMI/SMBIOS data After the system board is replaced, you must update the Universally Unique Identifier (UUID) and DMI/SMBIOS data in the integrated management module II (IMM2) on the new system board.
Page 50
is the 3-digit model number of the compute node. 2. Enter the following command: asu set SYSTEM_PROD_DATA.SysInfoSerialNum zzzzzzz where zzzzzzz is the 7-character serial number of the compute node. 3. Enter the following command: asu set SYSTEM_PROD_DATA.SysEncloseAssetTag aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the 33-character asset tag number of the compute node.
Page 51
asu set SYSTEM_PROD_DATA.SysInfoSerialNum zzzzzzz [--host ipaddress] [--user userid][--password password] where zzzzzzz is the 7-character serial number of the compute node. 3. Enter the following command: asu set SYSTEM_PROD_DATA.SysEncloseAssetTag aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa [--host ipaddress] [--user userid][--password password] where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the 33-character asset tag number of the compute node.
where zzzzzzz is the 7-character serial number of the compute node. 3. Enter the following command: asu set SYSTEM_PROD_DATA.SysEncloseAssetTag aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa --host ipaddress [--user userid][--password password] where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the 33-character asset tag number of the compute node. Enabling Features on Demand RAID software This topic provides information about enabling Features on Demand RAID software.
About this task You can use the LSI Logic Configuration Utility to perform the following tasks: v Set the device boot order v Add or remove devices from the boot list v Manage the RAID configuration Note: The hard disk drive in the RAID configuration must use the same type of interface and must have identical capacity and speed.
software or hardware. Instructions for obtaining an activation key are provided with your purchase of a Features on Demand authorization code. For information about Features on Demand, see http://www.ibm.com/systems/x/ fod/. Important: 1. If the compute node is configured in the Setup utility to boot in legacy mode, you must leave UEFI option ROM initialization enabled for devices for which Features on Demand feature keys are installed.
Page 55
v ISCSI or FCoE capabilities, which can be enabled through Features on Demand. When enabled, the ISCSI or FCoE operations are supported on the second vNIC of the physical port. Separate NIC, ISCSI, and FCoE drivers are provided to support all configurations. To obtain the device drivers, go to http://www.emulex.com/downloads/ibm/vfa- software-kits.html.
Page 56
Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259: Installation and Service Guide...
The ServerGuide Scripting Toolkit is a collection of system-configuration tools and installation scripts that you can use to deploy software to your compute node in a repeatable, predictable manner (see “Using Lenovo ServerGuide Scripting Toolkit” on page 48). v Operating-system installation instructions Download the latest operating-system installation instructions and install the operating system.
In addition to the ServerGuide Setup and Installation CD, you must have your operating-system CD to install the operating system. ServerGuide features This information provides an overview of the ServerGuide features. Features and functions can vary slightly with different versions of the ServerGuide program.
Flex System compute node in a repeatable, predictable manner. When the ServerGuide Scripting Toolkit is used with Lenovo ServerGuide, it provides a total solution for deploying Flex System compute nodes in an unattended mode.
The rear of the network access tag lists the IPv6 link local address (LLA), as shown in the following illustration. The MAC address is also available through the Setup utility, the CMM cinstatus command, and the CMM web interface. v For more information about the Setup utility, see “Using the Setup utility” on page 29.
v To assign IP addresses from the CMM web interface, click Mgt Module Management > Network > Ethernet. v If the CMM and compute nodes are set to use DHCP, and the CMM loses connectivity to the network, the CMM attempts to acquire a new IP address when network connectivity is restored.
Page 64
Table 2. IMM2 actions Selection Description System Status The System Status page allows you to view system status, active system events, and hardware health information. It provides quick links to the Server Power Actions, and Remote Control functions of the Server Management tab, and allows you to view an image of the last operating-system-failure screen capture.
Page 65
Table 2. IMM2 actions (continued) Selection Description Server Management Processors The Processors page displays the microprocessors in the system, along with their status and rated speed. You can click on a microprocessor name to display events and additional hardware information for the microprocessor.
Page 66
Table 2. IMM2 actions (continued) Selection Description IMM Management IMM Properties The IMM Properties page provides access to various properties, status, and settings for your IMM2: v The Firmware tab provides a link to the Server Firmware section of Server Management. v The IMM Date and Time Settings tab allows you to view and configure date and time settings for the IMM2.
Table 2. IMM2 actions (continued) Selection Description IMM Management Security The IMM Security page provides access to security properties, status, and settings for your IMM2: v The HTTPS Server tab allows you to enable or disable the HTTPS compute node and manage the certificates. v The CIM Over HTTPS tab allows you to enable or disable CIM over HTTPS and manage the certificates.
Potential conflicts with the LAN over USB interface In some situations, the LAN over USB interface can conflict with certain network configurations, applications, or both. For example, Open MPI attempts to use all the available network interfaces on a server or compute node. Open MPI detects the IMM2 LAN over USB interface and attempts to use it to communicate with other systems in a clustered environment.
Page 69
10. Return to the Device Manager. IBM USB Remote NDIS Network Device or Lenovo USB Remote NDIS Network Device appears under Network Adapters. 11. Use the Setup utility to view or set the IP address. See Table 3 on page 55 for information about the IP addresses.
Page 70
b. Turn on the compute node (see “Turning on the compute node” on page 15). c. When the prompt Press <F1> Setup is displayed, press F1. If you have set an administrator password, you must type the administrator password to access the full Setup utility menu.
(FRUs): v Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request without a service contract, you will be charged for the installation.
Page 72
Tier 1 CRU FRU part Index Description part number number Top cover (when ordering this part, order the Label Kit part number 00AG908 00AG903) Air baffle kit 00AG905 Flex System FC3172 2-port 8 Gb FC Adapter 69Y1941 Flex System IB6132 2-port FDR Infiniband Adapter 00D8532 Flex System EN4132 2-port 10 Gb Ethernet Adapter 00D8534...
Page 74
Tier 1 CRU FRU part Index Description part number number Heat sink, microprocessor 00AG887 2 GB USB Memory Key 42D0545 Alcohol wipes 59P4739 Flex System console breakout cable (models AC1, MC1, CTO) 81Y5287 Light path LED card 81Y5290 RFID label tag assembly - EMEA 00E6323 RFID label tag assembly - US 74Y8800...
Page 75
Tier 1 CRU FRU part Index Description part number number CRM handle kit 00AG915 Rear bulkhead assembly full wide 46M2833 1.8-inch SSD cage (includes two mounting sleeves and two SSD bezels) 00AG919 ServeRAID M1200 Series 1.8-inch SSD backplane 00AG922 ServeRAID M5100 1.8-inch drive cage 00Y3881 ServeRAID M5100 Series flex paddle card and cable assembly 00FE033...
Page 76
Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259: Installation and Service Guide...
Service bulletins Lenovo continually updates the support website with tips and techniques that you can use to solve problems that you might have with the Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259.
Page 78
v If the check log LED is lit, it indicates that a condition that causes an event to log in the IMM event log has occurred. v If the fault LED is lit, it indicates that an error has occurred; view the light path diagnostics panel and LEDs to isolate the failing component.
Light path diagnostics System board Mismatch Temperature Memory Future use only The following illustration shows the locations of the light path diagnostics LEDs on the system board. Light path diagnostics LEDs Use this information to diagnose possible errors that are indicated by the light path diagnostics LEDs.
Table 4. Light path diagnostics LEDs Lit light path diagnostics LED Description None The compute node is not sufficiently charged to display the LEDs on the system board. Battery error The system CMOS battery is not installed or is not working. BMC error Future use only.
Most recent versions of the Linux operating system come with a current version of IPMItool. For information about IPMItool, complete the following steps. Note: Changes are made periodically to the Lenovo website. The actual procedure might vary slightly from what is described in this document. 1. Go to http://www.ibm.com/developerworks.
“Viewing event logs through the Setup utility” on page 68. Lenovo Dynamic System Analysis Preboot diagnostic program Lenovo Dynamic System Analysis (DSA) Preboot diagnostic program collects and analyzes system information to aid in diagnosing compute node problems. DSA Preboot performs the following tasks:...
Page 83
1. DSA Preboot might appear to be unresponsive when you start the program. This is normal operation while the program loads. 2. In a multi-node complex, each node has a unique DSA interface. You can view node-specific information, such as error logs, from the unique DSA interface. To obtain DSA code and the Dynamic System Analysis Installation and User's Guide, go to http://www.ibm.com/support/entry/portal/docdisplay?lndocid=SERV-DSA.
089-000-000 v Failed: The test detected an error. v User Aborted: You stopped the test before it was completed. v Not Applicable: You attempted to test a device that is not present in the compute node. v Aborted: The test could not proceed because of the compute node configuration. v Warning: The test could not be run.
Page 85
089-801-000 • 089-802-000 089-801-000 CPU Stress Test Aborted Explanation: CPU Stress Test Aborted. Internal Program Error. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Turn off and restart the system. 2. Make sure that the DSA Diagnostic code is at the latest level. 3.
Page 86
089-803-000 • 089-901-000 089-803-000 CPU Stress Test Aborted Explanation: CPU Stress Test Aborted. Memory size is insufficient to run the test. At least 1GB is required. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 089-804-000...
Page 87
202-000-000 • 202-802-000 202-000-000 MemStr Test Passed Explanation: Test Passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 202-801-000 MemStr Test Aborted Explanation: Internal program error. Severity: Warning Serviceable: Yes Recoverable: No...
Page 88
202-803-000 • 202-902-000 202-803-000 MemStr Test Aborted Explanation: User pressed Ctrl-C. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 202-901-000 MemStr Test Failed Explanation: Test Failed. Severity: Error Serviceable: Yes Recoverable: No...
Page 89
201-000-000 • 201-000-002 4. Run the test again. 5. Execute the standard DSA memory diagnostics to validate all memory. 6. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Related Links: IBM Support Website Latest level of DSA...
Page 90
201-000-003 • 201-811-001 201-000-003 Standalone Memory Test Passed Explanation: Quick/Full Memory Test CPU 3 Passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-000-004 Standalone Memory Test Passed Explanation: Quick/Full Memory Test CPU 4 Passed.
Page 91
201-811-002 • 201-811-003 Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 92
201-812-000 • 201-812-002 201-812-000 Standalone Memory Test Aborted Explanation: Memory test is not supported for this system. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 93
201-812-003 • 201-813-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-812-003 Standalone Memory Test Aborted Explanation: Memory test is not supported for this system. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 94
201-813-002 • 201-813-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 95
201-814-000 • 201-814-002 201-814-000 Standalone Memory Test Aborted Explanation: Chipset Error: Can not disable Scubbing feature for CPU. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 96
201-814-003 • 201-815-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-814-003 Standalone Memory Test Aborted Explanation: Chipset Error: Can not disable Scubbing feature for CPU. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 97
201-815-002 • 201-815-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 98
201-816-000 • 201-816-002 201-816-000 Standalone Memory Test Aborted Explanation: Program Error with Full Memory Menu Option Selection. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 99
201-816-003 • 201-818-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-816-003 Standalone Memory Test Aborted Explanation: Program Error with Full Memory Menu Option Selection. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 100
201-818-002 • 201-818-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 101
201-819-000 • 201-819-002 201-819-000 Standalone Memory Test Aborted Explanation: The start-end address ranges in the restricted area of the memory. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 102
201-819-003 • 201-820-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-819-003 Standalone Memory Test Aborted Explanation: The start-end address ranges in the restricted area of the memory. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 103
201-820-002 • 201-820-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 104
201-821-000 • 201-821-002 201-821-000 Standalone Memory Test Aborted Explanation: Variable range MTRR registers are larger than fixed range MTRR registers. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 105
201-821-003 • 201-822-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-821-003 Standalone Memory Test Aborted Explanation: Variable range MTRR registers are larger than fixed range MTRR registers. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 106
201-822-002 • 201-822-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 107
201-824-000 • 201-824-002 201-824-000 Standalone Memory Test Aborted Explanation: Node Interleave feature must be OFF. Go to Setup and disable Node Interleave option and then re-run the test. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 108
201-824-003 • 201-826-001 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4. Make sure that DSA and BIOS/uEFI are at the latest level. Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-824-003...
Page 109
201-826-002 • 201-826-003 Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3.
Page 110
201-827-000 • 201-827-002 201-827-000 Standalone Memory Test Aborted Explanation: BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 111
201-827-003 • 201-844-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-827-003 Standalone Memory Test Aborted Explanation: BIOS: ECC function has been disabled by BIOS. Go to Setup and enable ECC generation. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps:...
Page 112
201-844-002 • 201-844-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 113
201-845-000 • 201-845-002 201-845-000 Standalone Memory Test Aborted Explanation: Chipset Error: Problem clearing MSR machine check control registers. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 114
201-845-003 • 201-859-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-845-003 Standalone Memory Test Aborted Explanation: Chipset Error: Problem clearing MSR machine check control registers. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 115
201-859-002 • 201-859-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 116
201-860-000 • 201-860-002 201-860-000 Standalone Memory Test Aborted Explanation: No OEM0 type 1 found. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 117
201-860-003 • 201-861-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-860-003 Standalone Memory Test Aborted Explanation: No OEM0 type 1 found. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 118
201-861-002 • 201-861-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 119
201-862-000 • 201-862-002 201-862-000 Standalone Memory Test Aborted Explanation: No OEM1 structure found. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 120
201-862-003 • 201-863-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-862-003 Standalone Memory Test Aborted Explanation: No OEM1 structure found. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 121
201-863-002 • 201-863-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 122
201-864-000 • 201-864-002 201-864-000 Standalone Memory Test Aborted Explanation: No GAS located in OEM1. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 123
201-864-003 • 201-865-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-864-003 Standalone Memory Test Aborted Explanation: No GAS located in OEM1. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 124
201-865-002 • 201-865-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 125
201-866-000 • 201-866-002 201-866-000 Standalone Memory Test Aborted Explanation: EFI-SAL Invalid parameter from GetMemoryMap function. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 126
201-866-003 • 201-867-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-866-003 Standalone Memory Test Aborted Explanation: EFI-SAL Invalid parameter from GetMemoryMap function. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 127
201-867-002 • 201-867-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 128
201-868-000 • 201-868-002 201-868-000 Standalone Memory Test Aborted Explanation: EFI/SAL: Buffer allocated in GetMemoryMap too small. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 129
201-868-003 • 201-869-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-868-003 Standalone Memory Test Aborted Explanation: EFI/SAL: Buffer allocated in GetMemoryMap too small. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 130
201-869-002 • 201-869-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 131
201-870-000 • 201-870-002 201-870-000 Standalone Memory Test Aborted Explanation: CPU Doamin in ACPI not valid. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 132
201-870-003 • 201-871-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-870-003 Standalone Memory Test Aborted Explanation: CPU Doamin in ACPI not valid. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 133
201-871-002 • 201-871-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 134
201-877-000 • 201-877-002 201-877-000 Standalone Memory Test Aborted Explanation: BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 135
201-877-003 • 201-878-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-877-003 Standalone Memory Test Aborted Explanation: BIOS: Sparing in Extended PCI reg. must be OFF. Go to setup and disable sparing. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps:...
Page 136
201-878-002 • 201-878-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 137
201-885-000 • 201-885-002 201-885-000 Standalone Memory Test Aborted Explanation: Processor does not support MTRR register manipulation. Can not write to memory without cache. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 138
201-885-003 • 201-886-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-885-003 Standalone Memory Test Aborted Explanation: Processor does not support MTRR register manipulation. Can not write to memory without cache. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No User response: Complete the following steps:...
Page 139
201-886-002 • 201-886-003 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s). Reconnect it to power. 4.
Page 140
201-899-000 • 201-899-003 201-899-000 Standalone Memory Test Aborted Explanation: Memory Diagnostics Test Aborted by user. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 201-899-001 Standalone Memory Test Aborted Explanation: Memory Diagnostics Test Aborted by user.
Page 141
201-901-000 • 201-901-002 201-901-000 Standalone Memory Test Failed Explanation: Memory Diagnostics Test Failed. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2.
Page 142
201-901-003 • 215-000-000 Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Perform the actions mentioned one at a time and try the test after each action. 2. If the problem remains, contact your technical-service representative. 3.
Page 143
215-801-000 • 215-802-000 IBM Support Website Latest level of DSA Latest level of BMC/IMM 215-801-000 Optical Drive Test Aborted Explanation: Optical Drive Test Aborted. Unable to communicate with driver. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 144
215-803-000 • 215-901-000 215-803-000 Optical Drive Test Failed Explanation: Optical Drive Test Failed. Disk may be in use by the operating system. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Wait for the system activity to cease 2.
Page 145
215-902-000 • 215-903-000 2. Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if damage is present. 3. Run the test again. 4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
Page 146
264-000-000 • 264-902-000 Latest level of DSA Latest level of BMC/IMM DSA tape drive test results The following messages can result when you run the tape drive test. 264-000-000 Tape Test Passed Explanation: Tape Test Passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links:...
Page 147
264-903-000 • 264-904-000 2. Run the test again. 3. Make sure that the drive firmware is at the latest level. 4. Rerun the test after upgrading to the latest firmware level. 5. If the failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
Page 148
264-905-000 • 264-906-000 Latest level of BMC/IMM 264-905-000 Tape Test Failed Explanation: Tape Test Failed. Software error: invalid request. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. If the system has stopped responding, turn off and restart the system. 2.
Page 149
264-907-000 • 217-000-000 264-907-000 Tape Test Failed Explanation: An error was found in the block address somewhere. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Clean the tape drive using the appropriate cleaning media and install new media. Related Links: IBM Support Website Latest level of DSA...
Page 150
217-800-000 • 407-000-000 217-800-000 HDD Test Aborted Explanation: HDD Test Aborted. The test was canceled. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Check cable connections. 2. Rerun the test. 3. Verify that Hard drive supports self test and self test logging. 4.
Page 151
407-800-000 • 409-000-000 Latest level of DSA Latest level of BMC/IMM 407-800-000 LSIESG:DiskDefaultDiagnostic Test Aborted Explanation: The test was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 407-900-000 LSIESG:DiskDefaultDiagnostic Test Failed Explanation: The hard drive self-test detected a failure.
Page 152
409-003-000 • 409-006-000 409-003-000 Nvidia::DiagnosticServiceProvider::Bandwidth Test Passed Explanation: Nvidia GPU Bandwidth test passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 409-004-000 Nvidia::DiagnosticServiceProvider::Query Test Passed Explanation: Nvidia GPU Query test passed.
Page 153
409-800-000 • 409-805-000 409-800-000 NVIDIA User Diagnostic Test Aborted Explanation: NVIDIA User Diagnostic test was canceled. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 409-803-000 Nvidia::DiagnosticServiceProvider::Bandwidth Test Aborted Explanation: Nvidia GPU Bandwidth test was canceled.
Page 154
409-806-000 • 409-903-000 409-806-000 Nvidia::DiagnosticServiceProvider::Binomial Test Aborted Explanation: Nvidia GPU Binomial test was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 409-900-000 NVIDIA User Diagnostic Test Failed Explanation: NVIDIA User Diagnostic Test Failed.
Page 155
409-904-000 • 409-906-000 Latest level of DSA Latest level of BMC/IMM 409-904-000 Nvidia::DiagnosticServiceProvider::Query Test Failed Explanation: Nvidia GPU Query Test Failed. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system. 2.
Page 156
166-000-001 • 166-802-001 Automatically notify Support: No User response: Complete the following steps: 1. Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system. 2. Verify that the power connectors to the GPU are connected firmly. Then power cycle the system. 3.
Page 157
166-803-001 • 166-805-001 Recoverable: No Automatically notify Support: No User response: Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2.
Page 158
166-806-001 • 166-808-001 Automatically notify Support: No User response: Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2.
Page 159
166-809-001 • 166-811-001 User response: Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2. Make sure that DSA and BMC/IMM are at the latest level. Related Links: IBM Support Website Latest level of DSA...
Page 160
166-812-001 • 166-814-001 2. Make sure that DSA and BMC/IMM are at the latest level. Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 166-812-001 IMM I2C Test Aborted Explanation: Parameter out of range. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No...
Page 161
166-815-001 • 166-817-001 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 166-815-001 IMM I2C Test Aborted Explanation: Invalid data field in Request. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Perform the actions mentioned one at a time and try the test after each action: 1.
Page 162
166-818-001 • 166-820-001 Latest level of DSA Latest level of BMC/IMM 166-818-001 IMM I2C Test Aborted Explanation: Cannot execute duplicated request. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Perform the actions mentioned one at a time and try the test after each action: 1.
Page 163
166-821-001 • 166-823-001 166-821-001 IMM I2C Test Aborted Explanation: Command response could not be provided. BMC initialization in progress. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Perform the actions mentioned one at a time and try the test after each action: 1.
Page 164
166-824-001 • 166-902-001 166-824-001 IMM I2C Test Aborted Explanation: Cannot execute command. Severity: Warning Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2.
Page 165
166-903-001 • 166-908-001 IBM Support Website Latest level of DSA Latest level of BMC/IMM 166-903-001 IMM I2C Test Failed Explanation: IMM Indicates failure in 9545A bus (BUS 2). Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Perform the actions mentioned one at a time and try the test after each action: 1.
Page 166
180-000-000 • 180-801-000 User response: Perform the actions mentioned one at a time and try the test after each action: 1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power. 2. Make sure that DSA and BMC/IMM are at the latest level. 3.
Page 167
180-901-000 • 405-001-000 180-901-000 Check-point Panel Test Failed Explanation: Check-point Panel Test Failed. Operator reported incorrect display. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Check the operator information panel cabling for loose or broken connections at both ends or damage to the cable.
Page 168
405-002-000 • 405-005-000 405-002-000 BRCM:TestEEPROM Test Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 405-003-000 BRCM:TestInternalMemory Test Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No...
Page 169
405-006-000 • 405-801-000 405-006-000 BRCM:TestLoopbackPhysical Test Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 405-007-000 BRCM:TestLEDs Test Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No...
Page 170
405-802-000 • 405-805-000 405-802-000 BRCM:TestEEPROM Test Aborted Explanation: The EEPROM test was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 405-803-000 BRCM:TestInternalMemory Test Aborted Explanation: The internal memory test was canceled.
Page 171
405-806-000 • 405-901-000 405-806-000 BRCM:TestLoopbackPhysical Test Aborted Explanation: Loopback testing at the physical layer was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 405-807-000 BRCM:TestLEDs Test Aborted Explanation: Verification of status LEDs was canceled.
Page 172
405-902-000 • 405-903-000 Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. 2.
Page 173
405-904-000 • 405-906-000 405-904-000 BRCM:TestInterrupt Test Failed Explanation: A failure was detected while testing interrupts. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
Page 174
405-907-000 • 218-001-000 3. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action. Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 405-907-000 BRCM:TestLEDs Test Failed Explanation: A failure was detected while verifying operation of the status LEDs.
Page 175
218-002-000 • 218-005-000 IBM Support Website Latest level of DSA Latest level of BMC/IMM 218-002-000 Brocade:SerdesLoopbackTest Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 218-003-000 Brocade:PCILoopbackTest Passed...
Page 176
218-006-000 • 218-802-000 Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 218-006-000 Brocade:InternalLoopbackTest Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 218-800-000 Brocade:MemoryTest Aborted...
Page 177
218-803-000 • 218-806-000 Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 218-803-000 Brocade:PCILoopbackTest Aborted Explanation: The test was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM...
Page 178
218-900-000 • 218-902-000 Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 218-900-000 Brocade:MemoryTest Failed Explanation: A failure was detected while testing the adapter memory. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 179
218-903-000 • 218-904-000 Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Rerun the test. 2. Verify whether the firmware is at proper level. 3. Rerun the test. 4. If the problem remains, contact your IBM technical-support representative. Related Links: IBM Support Website Latest level of DSA...
Page 180
218-905-000 • 516-000-000 218-905-000 Brocade:SerdesEthLoopbackTest Failed Explanation: A failure was detected during the Loopback test. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Rerun the test. 2. Verify whether the firmware is at proper level. 3.
Page 181
516-001-000 • 516-801-000 Latest level of BMC/IMM 516-001-000 ELXUCNA: NIC PHY LoopBackTest Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 516-002-000 ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Passed Explanation: The test passed.
Page 182
516-802-000 • 516-901-000 Latest level of DSA Latest level of BMC/IMM 516-802-000 ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Aborted Explanation: Verification of status LEDs was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 516-900-000 ELXUCNA: NIC MAC LoopBackTest Failed...
Page 183
516-902-000 • 408-001-000 Latest level of DSA Latest level of BMC/IMM 516-902-000 ELXUCNA: ELXUCNA: NIC LED(Beacon)Test Failed Explanation: A failure was detected while verifying operation of the status LEDs. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1.
Page 184
408-800-000 • 408-901-000 408-800-000 MLNX:MLNX_DiagnosticTestEthernetPort Test Aborted Explanation: Port Test was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 408-801-000 MLNX:MLNX_DiagnosticTestIBPort Test Aborted Explanation: Port Test was canceled. Severity: Warning Serviceable: No Recoverable: No...
Page 185
401-000-000 • 401-802-000 User response: Complete the following steps: 1. Make sure that the physical link of the port under test in the active state and a subnet manager running on the fabric to which the port is attached. 2. If these condition was met but the test keeps failing the port's adapter might be faulty. 3.
Page 186
401-901-001 • 406-000-000 Automatically notify Support: No User response: Complete the following steps: 1. Remove power cables, wait for 45 seconds, reconnect and rerun the test. 2. Make sure that the scalability cable connections are as per specification. 3. Make sure that DSA and BIOS/uEFI are at the latest level. 4.
Page 187
406-001-000 • 406-004-000 406-001-000 IANet:EEPROM Test Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 406-002-000 IANet:FIFO Test Passed Explanation: The test passed. Severity: Event Serviceable: No Recoverable: No...
Page 188
406-800-000 • 406-803-000 406-800-000 IANet:Registers Test Aborted Explanation: Registers test was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 406-801-000 IANet:EEPROM Test Aborted Explanation: EEPROM test was canceled. Severity: Warning Serviceable: No Recoverable: No...
Page 189
406-804-000 • 406-901-000 406-804-000 IANet:Loopback Test Aborted Explanation: Loopback test was canceled. Severity: Warning Serviceable: No Recoverable: No Automatically notify Support: No Related Links: IBM Support Website Latest level of DSA Latest level of BMC/IMM 406-900-000 IANet:Registers Test Failed Explanation: A failure was detected during the Registers test. Severity: Error Serviceable: Yes Recoverable: No...
Page 190
406-902-000 • 406-904-000 406-902-000 IANet:FIFO Test Failed Explanation: A failure was detected during the FIFO test. Severity: Error Serviceable: Yes Recoverable: No Automatically notify Support: No User response: Complete the following steps: 1. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component.
1. Check the Ethernet cable for damage and ensure correct cable type and attachment. 2. Check component firmware level and upgrade if necessary. The installed firmware level can be found in the DSA Diagnostic Event Log within the Firmware/VPD section for this component. 3.
Page 192
severity - device component severity is one of the following severity levels: v Critical: A key component in the server is no longer functioning. v Warning: The event might progress to a critical level. v System: The event is the result of a system error or a configuration change.
Page 193
Table 6. Events that automatically notify Support Automatically Notify Event ID Message String Support 40000086-00000000 Test Call Home Generated by user [arg1]. 40000087-00000000 Manual Call Home by user [arg1]: [arg2]. 80010202-0701ffff Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted. 80010202-2801ffff Numeric sensor [NumericSensorElementName] going low...
Page 194
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f010c-2004ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-2005ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-2006ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 195
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f010c-200dffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-200effff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-200f02ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 196
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f010c-2017ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-201802ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-2018ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 197
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f010c-201fffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-202001ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-2020ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 198
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f010c-2028ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-202902ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-2029ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 199
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f010c-2030ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010c-2581ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f010d-0400ffff The [StorageVolumeElementName] has been disabled due to a detected fault. 806f010d-0401ffff The [StorageVolumeElementName] has been disabled due to a detected fault.
Page 200
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f020d-0402ffff Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. 806f020d-0403ffff Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. 806f020d-0404ffff Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. 806f020d-0405ffff Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName].
Page 201
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f050c-2006ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f050c-2007ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f050c-2008ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 202
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f050c-2012ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f050c-2013ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f050c-2014ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 203
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f050c-201dffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f050c-201e01ff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f050c-201effff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 204
Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f050c-2027ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f050c-2028ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. 806f050c-202902ff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 205
40000001-00000000 • 40000002-00000000 Table 6. Events that automatically notify Support (continued) Automatically Notify Event ID Message String Support 806f060d-0403ffff Array [ComputerSystemElementName] has failed. 806f060d-0404ffff Array [ComputerSystemElementName] has failed. 806f060d-0405ffff Array [ComputerSystemElementName] has failed. 806f060d-0406ffff Array [ComputerSystemElementName] has failed. 806f060d-0407ffff Array [ComputerSystemElementName] has failed.
Page 206
40000003-00000000 • 40000006-00000000 40000003-00000000 Ethernet Data Rate modified from [arg1] to [arg2] by user [arg3]. Explanation: The specified user has changed the Ethernet data rate of the Integrated Management Module external network interface to the specified value. May also be shown as 4000000300000000 or 0x4000000300000000 Severity: Info Alert Category: none Serviceable: No...
Page 207
40000007-00000000 • 40000009-00000000 Serviceable: No CIM Information: Prefix: IMM and ID: 0006 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000007-00000000 Ethernet interface [arg1] by user [arg2]. Explanation: The specified user has enabled or disabled the Ethernet interface. May also be shown as 4000000700000000 or 0x4000000700000000 Severity: Info Alert Category: none...
Page 208
4000000a-00000000 • 4000000d-00000000 4000000a-00000000 IP subnet mask of network interface modified from [arg1] to [arg2] by user [arg3]. Explanation: The specified user has changed the subnet mask of the Integrated Management Module external network interface to the specified value. May also be shown as 4000000a00000000 or 0x4000000a00000000 Severity: Info Alert Category: none Serviceable: No...
Page 209
4000000e-00000000 • 40000010-00000000 CIM Information: Prefix: IMM and ID: 0013 SNMP Trap ID: Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Make sure that the IMM network cable is connected. 2. Make sure that there is a DHCP server on the network that can assign an IP address to the IMM. 4000000e-00000000 Remote Login Successful.
Page 210
40000011-00000000 • 40000014-00000000 40000011-00000000 Security: Login ID: [arg1] had [arg2] login failures from CLI at [arg3]. Explanation: A user has exceeded the maximum allowed number of unsuccessful login attempts from the command-line interface and has been prevented from logging in for the lockout period. May also be shown as 4000001100000000 or 0x4000001100000000 Severity: Warning Alert Category: System - Remote Login...
Page 211
40000015-00000000 • 40000017-00000000 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0020 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000015-00000000 Management Controller [arg1] reset was initiated by user [arg2]. Explanation: The Integrated Management Module has been reset.
Page 212
40000018-00000000 • 4000001b-00000000 40000018-00000000 LAN: Ethernet[[arg1]] interface is no longer active. Explanation: The IMM Ethernet interface has been disabled. May also be shown as 4000001800000000 or 0x4000001800000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0024 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 213
4000001c-00000000 • 4000001d-00000000 CIM Information: Prefix: IMM and ID: 0027 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000001c-00000000 Watchdog [arg1] Screen Capture Occurred. Explanation: An operating-system error has occurred, and the screen capture was successful. May also be shown as 4000001c00000000 or 0x4000001c00000000 Severity: Info Alert Category: System - other...
Page 214
4000001e-00000000 • 40000020-00000000 “Installing the LAN over USB Linux device driver” on page 58 “Installing the LAN over USB Windows device driver” on page 56 4000001e-00000000 Running the backup Management Controller [arg1] main application. Explanation: The IMM was unable to run the primary IMM image and has resorted to running the backup image. May also be shown as 4000001e00000000 or 0x4000001e00000000 Severity: Warning Alert Category: System - other...
Page 215
40000021-00000000 • 40000023-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000021-00000000 Management Controller [arg1] clock has been set from NTP server [arg2]. Explanation: The IMM clock has been set to the date and time that are provided by the Network Time Protocol server.
Page 216
40000024-00000000 • 40000027-00000000 40000024-00000000 Flash of [arg1] from [arg2] failed for user [arg3]. Explanation: The specified firmware has not been updated. May also be shown as 4000002400000000 or 0x4000002400000000 Severity: Info Alert Category: System - other Serviceable: No CIM Information: Prefix: IMM and ID: 0036 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only;...
Page 217
40000028-00000000 • 4000002a-00000000 CIM Information: Prefix: IMM and ID: 0039 SNMP Trap ID: 21 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Reconfigure the watchdog timer to a higher value. 2. Make sure that the IMM Ethernet-over-USB interface is enabled. 3.
Page 218
4000002b-00000000 • 4000002d-00000000 Alert Category: System - Other Serviceable: No CIM Information: Prefix: IMM and ID: 0042 SNMP Trap ID: 22 Automatically notify Support: No User response: Update the IMM firmware to the latest version. Related Links: “Updating firmware and device drivers” on page 25 IBM Flex System and IBM PureFlex Firmware Updates Best Practices 4000002b-00000000 Domain name set to [arg1].
Page 219
4000002e-00000000 • 40000031-00000000 User response: Information only; no action is required. 4000002e-00000000 DDNS registration successful. The domain name is [arg1]. Explanation: The DDNS registration was successful. May also be shown as 4000002e00000000 or 0x4000002e00000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0046 SNMP Trap ID: Automatically notify Support: No...
Page 220
40000032-00000000 • 40000034-00000000 CIM Information: Prefix: IMM and ID: 0049 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000032-00000000 IPv6 DHCP enabled by user [arg1]. Explanation: The specified user has enabled DHCPv6 on the Integrated Management Module. May also be shown as 4000003200000000 or 0x4000003200000000 Severity: Info Alert Category: none...
Page 221
40000035-00000000 • 40000038-00000000 40000035-00000000 IPv6 DHCP disabled by user [arg1]. Explanation: The specified user has disabled DHCPv6 on the Integrated Management Module. May also be shown as 4000003500000000 or 0x4000003500000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0053 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 222
40000039-00000000 • 4000003b-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000039-00000000 ENET[[arg1]] DHCPv6-HSTN=[arg2], DN=[arg3], IP@=[arg4], Pref=[arg5]. Explanation: The IPv6 DHCP-assigned address is active. May also be shown as 4000003900000000 or 0x4000003900000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0057...
Page 223
4000003c-00000000 • 4000003e-00000000 4000003c-00000000 Platform Watchdog Timer expired for [arg1]. Explanation: IMM has detected an OS did not start in the expected amount of time. May also be shown as 4000003c00000000 or 0x4000003c00000000 Severity: Error Alert Category: System - Loader timeout Serviceable: No CIM Information: Prefix: IMM and ID: 0060 SNMP Trap ID: 26...
Page 224
4000003f-00000000 • 40000042-00000000 4000003f-00000000 Web-HTTP port number changed from [arg1] to [arg2] by user [arg3]. Explanation: The specified user has changed the HTTP port number. New HTTP (web) connections must use the new port number. May also be shown as 4000003f00000000 or 0x4000003f00000000 Severity: Info Alert Category: none Serviceable: No...
Page 225
40000043-00000000 • 40000045-00000000 CIM Information: Prefix: IMM and ID: 0066 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000043-00000000 SNMP Agent port number changed from [arg1] to [arg2] by user [arg3]. Explanation: The specified user has changed the Simple Network Management Protocol (SNMP) agent port number. May also be shown as 4000004300000000 or 0x4000004300000000 Severity: Info Alert Category: none...
Page 226
40000046-00000000 • 40000049-00000000 40000046-00000000 Remote Presence port number changed from [arg1] to [arg2] by user [arg3]. Explanation: A user has modified the Remote Presence port number. May also be shown as 4000004600000000 or 0x4000004600000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0070 SNMP Trap ID: Automatically notify Support: No...
Page 227
4000004a-00000000 • 4000004d-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000004a-00000000 SNMP [arg1] disabled by user [arg2] . Explanation: The specified user has disabled the SNMPv1 or SNMPv3 agent. May also be shown as 4000004a00000000 or 0x4000004a00000000 Severity: Info Alert Category: none Serviceable: No...
Page 228
4000004e-00000000 • 40000050-00000000 May also be shown as 4000004d00000000 or 0x4000004d00000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0077 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000004e-00000000 Serial Redirection set by user [arg1]: Mode=[arg2], BaudRate=[arg3], StopBits=[arg4], Parity=[arg5], SessionTerminateSequence=[arg6].
Page 229
40000051-00000000 • 40000054-00000000 Automatically notify Support: No User response: Information only; no action is required. 40000051-00000000 Server Power Off Delay set to [arg1] by user [arg2]. Explanation: A user configured the Server Power Off Delay. May also be shown as 4000005100000000 or 0x4000005100000000 Severity: Info Alert Category: none Serviceable: No...
Page 230
40000055-00000000 • 40000057-00000000 Serviceable: No CIM Information: Prefix: IMM and ID: 0084 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000055-00000000 Synchronize time setting by user [arg1]: Mode=[arg2], NTPServerHost1=[arg3]:[arg4], NTPServerHost2=[arg5]:[arg6], NTPServerHost3=[arg7]:[arg8], NTPServerHost4=[arg9]:[arg10], NTPUpdateFrequency=[arg11]. Explanation: A user configured the Date and Time synchronize settings.
Page 231
40000058-00000000 • 4000005b-00000000 40000058-00000000 DNS servers set by user [arg1]: UseAdditionalServers=[arg2], PreferredDNStype=[arg3], IPv4Server1=[arg4], IPv4Server2=[arg5], IPv4Server3=[arg6], IPv6Server1=[arg7], IPv6Server2=[arg8], IPv6Server3=[arg9]. Explanation: The specified user has configured the DNS servers. May also be shown as 4000005800000000 or 0x4000005800000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0088 SNMP Trap ID:...
Page 232
4000005c-00000000 • 4000005e-00000000 CIM Information: Prefix: IMM and ID: 0091 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000005c-00000000 Secure CIM/XML(HTTPS) [arg1] by user [arg2]. Explanation: The secure CIM-XML port has been enabled or disabled. May also be shown as 4000005c00000000 or 0x4000005c00000000 Severity: Info Alert Category: none...
Page 233
4000005f-00000000 • 40000062-00000000 4000005f-00000000 Server timeouts set by user [arg1]: EnableOSWatchdog=[arg2], OSWatchdogTimout=[arg3], EnableLoaderWatchdog=[arg4], LoaderTimeout=[arg5]. Explanation: A user configures Server Timeouts. May also be shown as 4000005f00000000 or 0x4000005f00000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0095 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 234
40000063-00000000 • 40000065-00000000 Serviceable: No CIM Information: Prefix: IMM and ID: 0098 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000063-00000000 Global Login Account Security set by user [arg1]: PasswordRequired=[arg2], PasswordExpirationPeriod=[arg3], MinimumPasswordReuseCycle=[arg4], MinimumPasswordLength=[arg5], MinimumPasswordChangeInterval=[arg6], MaxmumLoginFailures=[arg7], LockoutAfterMaxFailures=[arg8], MinimumDifferentCharacters=[arg9], DefaultIDExpired=[arg10], ChangePasswordFirstAccess=[arg11].
Page 235
40000066-00000000 • 40000069-00000000 40000066-00000000 User [arg1] password modified. Explanation: The password for the specified user account has been changed. May also be shown as 4000006600000000 or 0x4000006600000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0102 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 236
4000006a-00000000 • 4000006d-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000006a-00000000 SSH Client key added for user [arg1]. Explanation: User locally defined an SSH Client key. May also be shown as 4000006a00000000 or 0x4000006a00000000 Severity: Info Alert Category: none Serviceable: No...
Page 237
4000006e-00000000 • 40000070-00000000 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0109 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000006e-00000000 Alert Configuration Global Event Notification set by user [arg1]: RetryLimit=[arg2], RetryInterval=[arg3], EntryInterval=[arg4].
Page 238
40000071-00000000 • 40000074-00000000 40000071-00000000 The power cap value changed from [arg1] watts to [arg2] watts by user [arg3]. Explanation: The power capping level has been changed. May also be shown as 4000007100000000 or 0x4000007100000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0113 SNMP Trap ID: Automatically notify Support: No...
Page 239
40000075-00000000 • 40000077-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000075-00000000 The measured power value exceeded the power cap value. Explanation: The measured power value has exceeded the power cap value. May also be shown as 4000007500000000 or 0x4000007500000000 Severity: Warning Alert Category: Warning - Power Serviceable: No...
Page 240
40000078-00000000 • 4000007b-00000000 40000078-00000000 Power capping was deactivated by user [arg1]. Explanation: The power capping control has been disabled. May also be shown as 4000007800000000 or 0x4000007800000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0120 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 241
4000007c-00000000 • 4000007f-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 4000007c-00000000 Dynamic Power Savings mode has been turned off by user [arg1]. Explanation: Dynamic Power Savings mode turned off by user. May also be shown as 4000007c00000000 or 0x4000007c00000000 Severity: Info Alert Category: none Serviceable: No...
Page 242
40000080-00000000 • 40000082-00000000 Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0127 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000080-00000000 Remote Control session started by user [arg1] in [arg2] mode. Explanation: Remote Control session started.
Page 243
40000083-00000000 • 40000085-00000000 40000083-00000000 The new minimum power cap value has returned below the power cap value. Explanation: The new minimum power cap value has returned below the power cap value. May also be shown as 4000008300000000 or 0x4000008300000000 Severity: Info Alert Category: Warning - Power Serviceable: No CIM Information: Prefix: IMM and ID: 0131...
Page 244
40000086-00000000 • 40000089-00000000 40000086-00000000 Test Call Home Generated by user [arg1]. Explanation: The specified user has generated a test automatic support notification. May also be shown as 4000008600000000 or 0x4000008600000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0134 SNMP Trap ID: Automatically notify Support: Yes User response: Information only;...
Page 245
4000008a-00000000 • 4000008c-00000000 CIM Information: Prefix: IMM and ID: 0137 SNMP Trap ID: 22 Automatically notify Support: No User response: 1. Turn off the server and disconnect it from the power source. You must disconnect the server from ac power to reset the IMM.
Page 246
4000008d-00000000 • 4000008f-00000000 CIM Information: Prefix: IMM and ID: 0140 SNMP Trap ID: 30 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Make sure that the correct login ID and password are being used. 2.
Page 247
40000090-00000000 • 40000093-00000000 40000090-00000000 The bare metal update application reports a status of [arg1]. Explanation: Bare Metal Update Application Status May also be shown as 4000009000000000 or 0x4000009000000000 Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: IMM and ID: 0144 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only;...
Page 248
40000094-00000000 • 40000096-00000000 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 40000094-00000000 User [arg1] has generated a new encryption key pair and installed a self-signed certificate for the TKLM client. Explanation: User generated a new encryption key pair and installed a self-signed certificate for the TKLM client. May also be shown as 4000009400000000 or 0x4000009400000000 Severity: Info Alert Category: none...
Page 249
40000097-00000000 • 4000009a-00000000 40000097-00000000 User [arg1] has imported a server certificate for the TKLM server. Explanation: User imported a server certificate for the TKLM Server. May also be shown as 4000009700000000 or 0x4000009700000000 Severity: Info Alert Category: none Serviceable: No CIM Information: Prefix: IMM and ID: 0151 SNMP Trap ID: Automatically notify Support: No...
Page 250
4000009b-00000000 • 4000009e-00000000 SNMP Trap ID: 30 Automatically notify Support: No User response: Information only; no action is required. 4000009b-00000000 Security: Userid: [arg1] had [arg2] login failures from IPMI serial client. Explanation: A user was not able to log in to a Management Controller from an IPMI serial client. May also be shown as 4000009b00000000 or 0x4000009b00000000 Severity: Info Alert Category: System - Remote Login...
Page 251
4000009f-00000000 • 400000a1-00000000 Alert Category: System - Remote Login Serviceable: No CIM Information: Prefix: IMM and ID: 0158 SNMP Trap ID: 30 Automatically notify Support: No User response: Information only; no action is required. 4000009f-00000000 User [arg1] has initiated a TKLM Server Connection Test to check connectivity to server [arg2].
Page 252
400000a2-00000000 • 400000a5-00000000 400000a2-00000000 User [arg1] has [arg2] file [arg3] from [arg4]. Explanation: User has mounted/unmounted file from URL or server. May also be shown as 400000a200000000 or 0x400000a200000000 Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: IMM and ID: 0162 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only;...
Page 253
400000a6-00000000 • 400000a9-00000000 SNMP Trap ID: 22 Automatically notify Support: No User response: Install a new certificate. 400000a6-00000000 The server was restarted for an unknown reason. Explanation: The server was restarted for an unknown reason. May also be shown as 400000a600000000 or 0x400000a600000000 Severity: Info Alert Category: System - Other Serviceable: No...
Page 254
400000aa-00000000 • 400000ac-00000000 Alert Category: System - Other Serviceable: No CIM Information: Prefix: IMM and ID: 0169 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only; no action is required. 400000aa-00000000 The server was restarted when the watchdog expired.. Explanation: Server was restarted when the watchdog expired.
Page 255
400000ad-00000000 • 400000b0-00000000 400000ad-00000000 The server was automatically powered on because the power restore policy is set to restore previous power state.. Explanation: Server was automatically powered on because the power restore policy is set to restore previous power state. May also be shown as 400000ad00000000 or 0x400000ad00000000 Severity: Info Alert Category: System - Other...
Page 256
400000b1-00000000 • 400000b3-00000000 CIM Information: Prefix: IMM and ID: 0176 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only; no action is required. 400000b1-00000000 The server was powered up via Real Time Clock (scheduled power on). Explanation: Server was powered up via Real Time Clock (scheduled power on). May also be shown as 400000b100000000 or 0x400000b100000000 Severity: Info Alert Category: System - Other...
Page 257
400000b4-00000000 • 400000b7-00000000 400000b4-00000000 The server was powered off via pushbutton. Explanation: Server was powered off via pushbutton. May also be shown as 400000b400000000 or 0x400000b400000000 Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: IMM and ID: 0180 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only;...
Page 258
400000b8-00000000 • 400000bb-00000000 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only; no action is required. 400000b8-00000000 The server was popwered off via Platform Event Filter. Explanation: Server was power off via Platform Event Filter. May also be shown as 400000b800000000 or 0x400000b800000000 Severity: Info Alert Category: System - Other Serviceable: No...
Page 259
400000bc-00000000 • 400000be-00000000 Alert Category: System - Other Serviceable: No CIM Information: Prefix: IMM and ID: 0187 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only; no action is required. 400000bc-00000000 Management Controller [arg1] reset was initiated by CMM. Explanation: Management Controller reset was initiated by CMM.
Page 260
400000bf-00000000 • 80010202-2801ffff 400000bf-00000000 Operating System status has changed to [arg1]. Explanation: Operating System status change. May also be shown as 400000bf00000000 or 0x400000bf00000000 Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: IMM and ID: 0191 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only;...
Page 261
80010701-3701ffff • 80010901-3701ffff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0480 SNMP Trap ID: 1 Automatically notify Support: Yes User response: Replace the CMOS battery. 80010701-3701ffff Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted. Explanation: The inlet 1 temperature has exceeded its specified threshold. The compute node has attempted a soft shutdown.
Page 262
80010901-3702ffff • 80010b01-3701ffff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0494 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
Page 263
80010b01-3702ffff • 80030006-2101ffff May also be shown as 80010b013701ffff or 0x80010b013701ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0498 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1.
Page 264
8003010c-2581ffff • 8003010d-2b81ffff 8003010c-2581ffff Sensor [SensorElementName] has asserted. Explanation: IMM has reported a SMI Lane Failover. May also be shown as 8003010c2581ffff or 0x8003010c2581ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0508 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event.
Page 265
8003010e-2581ffff • 80030112-0601ffff Related Links: “Removing a flash DIMM” on page 730 “Installing a flash DIMM” on page 730 8003010e-2581ffff Sensor [SensorElementName] has asserted. Explanation: A sensor has been detected. May also be shown as 8003010e2581ffff or 0x8003010e2581ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0508...
Page 266
8005010d-2b81ffff • 80070101-030101ff 8005010d-2b81ffff Sensor [SensorElementName] has indicated limit exceeded. Explanation: A Sensor limit has been exceeded. May also be shown as 8005010d2b81ffff or 0x8005010d2b81ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0512 SNMP Trap ID: Automatically notify Support: No User response: The device has exceeded specified temperature limits and should be replaced.
Page 267
80070101-0301ffff • 80070101-030202ff CIM Information: Prefix: PLAT and ID: 0520 SNMP Trap ID: 12 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
Page 268
80070101-0302ffff • 80070101-0481ffff Alert Category: Warning - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0520 SNMP Trap ID: 12 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
Page 269
80070101-2c0101ff • 80070101-2c0201ff 80070101-2c0101ff Sensor [SensorElementName] has transitioned from normal to non-critical state. Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified threshold. May also be shown as 800701012c0101ff or 0x800701012c0101ff Severity: Warning Alert Category: Warning - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0520...
Page 270
80070101-2c02ffff • 80070101-2c04ffff 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 271
80070101-2d01ffff • 8007010d-2b81ffff CIM Information: Prefix: PLAT and ID: 0520 SNMP Trap ID: 12 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
Page 272
8007010d-3030ffff • 8007010f-2201ffff CIM Information: Prefix: PLAT and ID: 0520 SNMP Trap ID: 60 Automatically notify Support: No User response: Information only; warranty is about to expire but no action is required. 8007010d-3030ffff Sensor [SensorElementName] has transitioned from normal to non-critical state. Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.
Page 273
8007010f-2582ffff • 80070201-0481ffff User response: Complete the following steps: 1. Check the IBM support site for service bulletins or firmware updates that apply to this GPT error. 2. Set the UEFI setting "DISK GPT Recovery" to "Automatic". 3. Replace the corrupt disk. 8007010f-2582ffff Sensor [SensorElementName] has transitioned from normal to non-critical state.
Page 274
80070202-0701ffff • 8007020d-2582ffff Automatically notify Support: No User response: 1. Check the IMM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and correctly installed.
Page 275
8007020d-3030ffff • 8007020f-2582ffff CIM Information: Prefix: PLAT and ID: 0522 SNMP Trap ID: 50 Automatically notify Support: No User response: RAID Vol State : 8007020d-3030ffff Sensor [SensorElementName] has transitioned to critical from a less severe state. Explanation: This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.
Page 276
80070217-2c01ffff • 80070217-2c02ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 80070217-2c01ffff Sensor [SensorElementName] has transitioned to critical from a less severe state. Explanation: The I/O expansion adapter in I/O expansion connector 1 has reported a fault.
Page 277
80070217-2c03ffff • 80070219-0701ffff 80070217-2c03ffff Sensor [SensorElementName] has transitioned to critical from a less severe state. Explanation: The I/O expansion adapter in I/O expansion connector 3 has reported a fault. May also be shown as 800702172c03ffff or 0x800702172c03ffff Severity: Error Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0522 SNMP Trap ID: 50...
Page 278
8007021b-0301ffff • 80070221-1f09ffff CIM Information: Prefix: PLAT and ID: 0522 SNMP Trap ID: 50 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 279
80070221-1f0affff • 80070301-030101ff Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0522 SNMP Trap ID: 50 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 280
80070301-0301ffff • 80070301-0302ffff 80070301-0301ffff Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. Explanation: The microprocessor 1 temperature has risen above its specified threshold, causing a hard shutdown of the node. May also be shown as 800703010301ffff or 0x800703010301ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes...
Page 281
80070301-0481ffff • 80070301-2c0101ff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0524 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
Page 282
80070301-2c01ffff • 80070301-2c02ffff 80070301-2c01ffff Sensor [SensorElementName] has transitioned to non-recoverable from a less severe state. Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified threshold. The compute node has attempted a soft shutdown. May also be shown as 800703012c01ffff or 0x800703012c01ffff Severity: Error Alert Category: Critical - Temperature...
Page 283
80070301-2c0302ff • 80070301-2c03ffff Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 284
80070301-2c0402ff • 80070301-2d01ffff 80070301-2c0402ff Sensor Mezz Exp 4 temp has transitioned to non-recoverable from a less severe state. Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 4 has exceeded its specified threshold. The compute node has attempted a soft shutdown. May also be shown as 800703012c0402ff or 0x800703012c0402ff Severity: Error Alert Category: Critical - Temperature...
Page 285
8007030d-2582ffff • 8007030d-3030ffff User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 286
80070401-2c01ffff • 80070401-2c04ffff 80070401-2c01ffff Sensor [SensorElementName] has transitioned to non-critical from a more severe state. Explanation: The previously high temperature of the I/O expansion adapter in I/O expansion connector 1 has returned to below its specified threshold. May also be shown as 800704012c01ffff or 0x800704012c01ffff Severity: Info Alert Category: System - Other Serviceable: No...
Page 287
80070601-2c01ffff • 80070601-2c03ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0526 SNMP Trap ID: 22 Automatically notify Support: No User response: Information only; no action is required. 80070601-2c01ffff Sensor [SensorElementName] has transitioned to non-recoverable. Explanation: The temperature of the I/O expansion adapter in I/O expansion connector 1 has exceeded its specified threshold.
Page 288
80070601-2c04ffff • 8007060f-2201ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0530 SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2.
Page 289
80070614-2201ffff • 80070617-2c02ffff 80070614-2201ffff Sensor [SensorElementName] has transitioned to non-recoverable. Explanation: Trusted Platform Module (TPM) initialization error. May also be shown as 800706142201ffff or 0x800706142201ffff Severity: Error Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0530 SNMP Trap ID: 50 Automatically notify Support: No User response: This is a UEFI detected event.
Page 290
80070617-2c03ffff • 80070617-2c04ffff Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0530 SNMP Trap ID: 50 Automatically notify Support: No User response: Complete the following steps: 1. Remove the I/O expansion adapter in I/O expansion connector 2. 2.
Page 291
8008001b-1f07ffff • 8008001b-1f08ffff User response: Complete the following steps: 1. Remove the I/O expansion adapter in I/O expansion connector 4. 2. Try to power on the chassis. v If the chassis successfully powers on, complete the following steps: a. Check the ServerProven website to make sure that recently installed components are compatible with the chassis.
Page 292
8008010f-2101ffff • 8008011b-1f07ffff On a LOM model compute node, if you are utilizing LOM and it is not working ensure you have the necessary fabric connector installed. v To utilize the LOM: – have the LOM model compute node – have the corresponding fabric connector installed v Information regarding the fabric connectors: –...
Page 293
8008011b-1f08ffff • 8009000c-0701ffff – I/O expansion adaptor in I/O expansion slot 3 and the fabric connector in slot 2 utilize the same connector and only one of the two can be installed at a time. 8008011b-1f08ffff Device [LogicalDeviceElementName] has been added. Explanation: The fabric connector for LAN On Motherboard (LOM) in location 2 is present.
Page 294
8009010c-0701ffff • 800a040d-2b81ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 8009010c-0701ffff Device [LogicalDeviceElementName] has been enabled. Explanation: The user has switched from Acoustic mode to Performance mode. May also be shown as 8009010c0701ffff or 0x8009010c0701ffff Severity: Info Alert Category: System - Other Serviceable: No...
Page 295
800a060d-2b81ffff • 800b030c-2581ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0548 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 800a060d-2b81ffff Sensor [SensorElementName] has indicated a degraded state. Explanation: The FlashDIMM agent has indicated a FlashDIMM on Compute Book 1 has transitioned to a degraded state.
Page 296
800b050c-2581ffff • 806f0007-0302ffff SNMP Trap ID: 43 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 297
806f0009-0701ffff • 806f000d-0401ffff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0042 SNMP Trap ID: 40 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 298
806f000d-0402ffff • 806f000d-0405ffff 806f000d-0402ffff The [StorageVolumeElementName] has been added. Explanation: Hard disk drive 2 has been installed. May also be shown as 806f000d0402ffff or 0x806f000d0402ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0162 SNMP Trap ID: 5 Automatically notify Support: No User response: Information only;...
Page 299
806f000d-0406ffff • 806f000f-220100ff SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 806f000d-0406ffff The [StorageVolumeElementName] has been added. Explanation: Hard disk drive 6 has been installed. May also be shown as 806f000d0406ffff or 0x806f000d0406ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No...
Page 300
806f000f-220101ff • 806f000f-220103ff 806f000f-220101ff The System [ComputerSystemElementName] has detected no memory in the system. Explanation: No memory was detected in the system. May also be shown as 806f000f220101ff or 0x806f000f220101ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0794 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 301
806f000f-220104ff • 806f000f-22010aff Related Links: “Finding the UEFI diagnostic code” on page 648 806f000f-220104ff The System [ComputerSystemElementName]has encountered a motherboard failure. Explanation: A fatal motherboard failure has been detected in the system due to ABR Status or Firmware Error. May also be shown as 806f000f220104ff or 0x806f000f220104ff Severity: Error Alert Category: Critical - Other Serviceable: Yes...
Page 302
806f000f-22010bff • 806f000f-2201ffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 303
806f0013-1701ffff • 806f0021-1201ffff CIM Information: Prefix: PLAT and ID: 0184 SNMP Trap ID: 50 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 304
806f0021-2201ffff • 806f0021-25820902 Automatically notify Support: Yes User response: Verify system SMP scaling and system configuration match. If SMP connector has been removed then confirm each system node configured for standalone operation. 806f0021-2201ffff Fault in slot [PhysicalConnectorSystemElementName] on system [ComputerSystemElementName]. Explanation: A fault in a slot has been detected.
Page 305
806f0021-25820903 • 806f0023-2101ffff SNMP Trap ID: 50 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 306
806f0028-2101ffff • 806f0107-0301ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0368 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 806f0028-2101ffff Sensor [SensorElementName] is unavailable or degraded on management system [ComputerSystemElementName].
Page 307
806f0107-0302ffff • 806f0107-2584ffff User response: Complete the following steps until the problem is solved: 1. Check the Chassis Management Module or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 308
806f0109-0701ffff • 806f010c-2001ffff 6. Replace the specified microprocessor. 806f0109-0701ffff [PowerSupplyElementName] has been Power Cycled. Explanation: The compute node Host Power has been powered off and powered on. May also be shown as 806f01090701ffff or 0x806f01090701ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0108 SNMP Trap ID:...
Page 309
806f010c-2002ffff • 806f010c-200401ff “Finding the UEFI diagnostic code” on page 648 806f010c-2002ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c2002ffff or 0x806f010c2002ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41...
Page 310
806f010c-2004ffff • 806f010c-2006ffff User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 311
806f010c-200701ff • 806f010c-2007ffff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 312
806f010c-200801ff • 806f010c-200901ff 806f010c-200801ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c200801ff or 0x806f010c200801ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 313
806f010c-2009ffff • 806f010c-200affff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-2009ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 314
806f010c-200b01ff • 806f010c-200bffff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 315
806f010c-200c01ff • 806f010c-200d02ff 806f010c-200c01ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c200c01ff or 0x806f010c200c01ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 316
806f010c-200dffff • 806f010c-200f02ff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-200dffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 317
806f010c-200fffff • 806f010c-201002ff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 318
806f010c-2010ffff • 806f010c-201202ff 806f010c-2010ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c2010ffff or 0x806f010c2010ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 319
806f010c-2012ffff • 806f010c-2013ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-2012ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 320
806f010c-2014ffff • 806f010c-201502ff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 321
806f010c-2015ffff • 806f010c-2016ffff 806f010c-2015ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c2015ffff or 0x806f010c2015ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 322
806f010c-2017ffff • 806f010c-2018ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-2017ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 323
806f010c-201901ff • 806f010c-2019ffff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 324
806f010c-201a01ff • 806f010c-201b01ff 806f010c-201a01ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c201a01ff or 0x806f010c201a01ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 325
806f010c-201bffff • 806f010c-201cffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-201bffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 326
806f010c-201d01ff • 806f010c-201dffff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 327
806f010c-201e01ff • 806f010c-201f01ff 806f010c-201e01ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c201e01ff or 0x806f010c201e01ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 328
806f010c-201fffff • 806f010c-2020ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-201fffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 329
806f010c-202101ff • 806f010c-2021ffff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 330
806f010c-2022ffff • 806f010c-2023ffff 806f010c-2022ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c2022ffff or 0x806f010c2022ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 331
806f010c-2024ffff • 806f010c-2025ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-2024ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 332
806f010c-202602ff • 806f010c-2026ffff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 333
806f010c-202702ff • 806f010c-202802ff 806f010c-202702ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c202702ff or 0x806f010c202702ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 334
806f010c-2028ffff • 806f010c-2029ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-2028ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 335
806f010c-202a02ff • 806f010c-202affff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 336
806f010c-202b02ff • 806f010c-202c02ff 806f010c-202b02ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c202b02ff or 0x806f010c202b02ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 337
806f010c-202cffff • 806f010c-202dffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-202cffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 338
806f010c-202e02ff • 806f010c-202effff CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 339
806f010c-202f02ff • 806f010c-203002ff 806f010c-202f02ff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An uncorrectable memory error has been detected. May also be shown as 806f010c202f02ff or 0x806f010c202f02ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0138 SNMP Trap ID: 41 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 340
806f010c-2030ffff • 806f010d-0400ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f010c-2030ffff Uncorrectable error detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 341
806f010d-0401ffff • 806f010d-0402ffff CIM Information: Prefix: PLAT and ID: 0164 SNMP Trap ID: 5 Automatically notify Support: Yes User response: Complete the following steps until the problem is solved: 1. Check the Support Portal for service bulletins and RETAIN tips related to your drive. 2.
Page 342
806f010d-0403ffff • 806f010d-0405ffff 806f010d-0403ffff The [StorageVolumeElementName] has been disabled due to a detected fault. Explanation: The hard disk drive controller has detected a fault in hard disk drive 3. Hard disk drive 3 is now defunct. May also be shown as 806f010d0403ffff or 0x806f010d0403ffff Severity: Error Alert Category: Critical - Hard Disk drive Serviceable: Yes...
Page 343
806f010d-0406ffff • 806f010d-2b81ffff 1. Check the Support Portal for service bulletins and RETAIN tips related to your drive. 2. Check the Support Portal for firmware updates related to your drive. 3. Replace the drive. 4. Check for any other RAID-related errors. 806f010d-0406ffff The [StorageVolumeElementName] has been disabled due to a detected fault.
Page 344
806f010f-220100ff • 806f011b-0c01ffff CIM Information: Prefix: PLAT and ID: 0164 SNMP Trap ID: 5 Automatically notify Support: Yes User response: The drive controller has indicated a fault state and the device is not operational 806f010f-220100ff The System [ComputerSystemElementName] encountered a firmware hang. Explanation: A system firmware hang has been detected.
Page 345
806f011b-1f03ffff • 806f0123-2101ffff Automatically notify Support: Yes User response: Complete the following steps until the problem is solved: 1. Make sure that the cable from the light path LED card to the system board is securely connected. 2. Replace the light path diagnostics panel. 806f011b-1f03ffff The connector [PhysicalConnectorElementName] has encountered a configuration error.
Page 346
806f0207-0301ffff • 806f0207-2584ffff 806f0207-0301ffff [ProcessorElementName] has Failed with FRB1/BIST condition. Explanation: A Processor has Failed - FRB1/BIST condition. May also be shown as 806f02070301ffff or 0x806f02070301ffff Severity: Error Alert Category: Critical - CPU Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0044 SNMP Trap ID: 40 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 347
806f020d-0400ffff • 806f020d-0403ffff “Finding the UEFI diagnostic code” on page 648 806f020d-0400ffff Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. Explanation: Failure predicted (PFA) on the hard drive. May also be shown as 806f020d0400ffff or 0x806f020d0400ffff Severity: Warning Alert Category: System - Predicted Failure Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0168 SNMP Trap ID: 27...
Page 348
806f020d-0404ffff • 806f020d-0406ffff CIM Information: Prefix: PLAT and ID: 0168 SNMP Trap ID: 27 Automatically notify Support: Yes User response: Replace the hard disk drive at the next maintenance period. 806f020d-0404ffff Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. Explanation: Failure predicted (PFA) on the hard drive. May also be shown as 806f020d0404ffff or 0x806f020d0404ffff Severity: Warning Alert Category: System - Predicted Failure...
Page 349
806f020d-0407ffff • 806f0221-1201ffff 806f020d-0407ffff Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. Explanation: Failure predicted (PFA) on the hard drive. May also be shown as 806f020d0407ffff or 0x806f020d0407ffff Severity: Warning Alert Category: System - Predicted Failure Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0168 SNMP Trap ID: 27 Automatically notify Support: Yes User response: Replace the hard disk drive at the next maintenance period.
Page 350
806f0223-2101ffff • 806f030c-200101ff SNMP Trap ID: Automatically notify Support: No User response: SMP connector has been installed. Verify system has been preconfigured for scaled operation. System reboot may be required. 806f0223-2101ffff Powering off system [ComputerSystemElementName] initiated by [WatchdogElementName]. Explanation: The IPMI watchdog timer has expired. The compute node has been powered off. May also be shown as 806f02232101ffff or 0x806f02232101ffff Severity: Info Alert Category: System - Other...
Page 351
806f030c-2001ffff • 806f030c-2002ffff 806f030c-2001ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2001ffff or 0x806f030c2001ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 352
806f030c-200301ff • 806f030c-200401ff “Finding the UEFI diagnostic code” on page 648 806f030c-200301ff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c200301ff or 0x806f030c200301ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41...
Page 353
806f030c-2004ffff • 806f030c-2005ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f030c-2004ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error).
Page 354
806f030c-200601ff • 806f030c-200701ff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 355
806f030c-2007ffff • 806f030c-2008ffff CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 356
806f030c-200901ff • 806f030c-2009ffff Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 357
806f030c-200a01ff • 806f030c-200bffff 806f030c-200a01ff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c200a01ff or 0x806f030c200a01ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 358
806f030c-200cffff • 806f030c-200dffff “Finding the UEFI diagnostic code” on page 648 806f030c-200cffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c200cffff or 0x806f030c200cffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41...
Page 359
806f030c-200e02ff • 806f030c-200f02ff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f030c-200e02ff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error).
Page 360
806f030c-200fffff • 806f030c-2010ffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 361
806f030c-201102ff • 806f030c-201202ff CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 362
806f030c-2012ffff • 806f030c-201302ff Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 363
806f030c-2013ffff • 806f030c-2014ffff 806f030c-2013ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2013ffff or 0x806f030c2013ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 364
806f030c-201502ff • 806f030c-201602ff “Finding the UEFI diagnostic code” on page 648 806f030c-201502ff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c201502ff or 0x806f030c201502ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41...
Page 365
806f030c-2016ffff • 806f030c-2017ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f030c-2016ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error).
Page 366
806f030c-201802ff • 806f030c-201901ff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 367
806f030c-2019ffff • 806f030c-201affff CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 368
806f030c-201bffff • 806f030c-201c01ff Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 369
806f030c-201cffff • 806f030c-201dffff 806f030c-201cffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c201cffff or 0x806f030c201cffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 370
806f030c-201e01ff • 806f030c-201fffff “Finding the UEFI diagnostic code” on page 648 806f030c-201e01ff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c201e01ff or 0x806f030c201e01ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41...
Page 371
806f030c-2020ffff • 806f030c-2021ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f030c-2020ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error).
Page 372
806f030c-2022ffff • 806f030c-2023ffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 373
806f030c-2024ffff • 806f030c-2025ffff CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 374
806f030c-202602ff • 806f030c-2026ffff Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 375
806f030c-202702ff • 806f030c-202802ff 806f030c-202702ff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c202702ff or 0x806f030c202702ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 376
806f030c-2028ffff • 806f030c-2029ffff “Finding the UEFI diagnostic code” on page 648 806f030c-2028ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2028ffff or 0x806f030c2028ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41...
Page 377
806f030c-202affff • 806f030c-202c02ff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f030c-202affff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error).
Page 378
806f030c-202cffff • 806f030c-202dffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 379
806f030c-202e02ff • 806f030c-202f02ff CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 380
806f030c-202fffff • 806f030c-203002ff Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 381
806f030c-2030ffff • 806f030d-0400ffff 806f030c-2030ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory error discovered during boot..(not a runtime error). May also be shown as 806f030c2030ffff or 0x806f030c2030ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0136 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 382
806f030d-0401ffff • 806f030d-0404ffff 806f030d-0401ffff Hot Spare enabled for [ComputerSystemElementName]. Explanation: A hot spare drive is available. May also be shown as 806f030d0401ffff or 0x806f030d0401ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0170 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 383
806f030d-0405ffff • 806f0313-1701ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 806f030d-0405ffff Hot Spare enabled for [ComputerSystemElementName]. Explanation: A hot spare drive is available. May also be shown as 806f030d0405ffff or 0x806f030d0405ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0170...
Page 384
806f0323-2101ffff • 806f032b-2101ffff Severity: Error Alert Category: Critical - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0228 SNMP Trap ID: 50 Automatically notify Support: No User response: Check the operating-system logs and resolve any issues related the NMI. 806f0323-2101ffff Power cycle of system [ComputerSystemElementName] initiated by watchdog [WatchdogElementName].
Page 385
806f040c-2001ffff • 806f040c-2003ffff User response: Attempt to flash the IMM firmware to the same level on all nodes. 806f040c-2001ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been Disabled. May also be shown as 806f040c2001ffff or 0x806f040c2001ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID:...
Page 386
806f040c-2004ffff • 806f040c-2006ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f040c-2004ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been Disabled.
Page 387
806f040c-2007ffff • 806f040c-2009ffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 388
806f040c-200affff • 806f040c-200cffff CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 389
806f040c-200dffff • 806f040c-200effff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 390
806f040c-200fffff • 806f040c-2011ffff 806f040c-200fffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been Disabled. May also be shown as 806f040c200fffff or 0x806f040c200fffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event.
Page 391
806f040c-2012ffff • 806f040c-2014ffff “Finding the UEFI diagnostic code” on page 648 806f040c-2012ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been Disabled. May also be shown as 806f040c2012ffff or 0x806f040c2012ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event.
Page 392
806f040c-2015ffff • 806f040c-2017ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f040c-2015ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been Disabled.
Page 393
806f040c-2018ffff • 806f040c-201affff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 394
806f040c-201bffff • 806f040c-201dffff CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 395
806f040c-201effff • 806f040c-201fffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 396
806f040c-2020ffff • 806f040c-2022ffff 806f040c-2020ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been Disabled. May also be shown as 806f040c2020ffff or 0x806f040c2020ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event.
Page 397
806f040c-2023ffff • 806f040c-2025ffff “Finding the UEFI diagnostic code” on page 648 806f040c-2023ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been Disabled. May also be shown as 806f040c2023ffff or 0x806f040c2023ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event.
Page 398
806f040c-2026ffff • 806f040c-2028ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f040c-2026ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been Disabled.
Page 399
806f040c-2029ffff • 806f040c-202bffff Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 400
806f040c-202cffff • 806f040c-202effff CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 401
806f040c-202fffff • 806f040c-2030ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 402
806f040c-2581ffff • 806f0507-0301ffff 806f040c-2581ffff [PhysicalMemoryElementName] Disabled on Subsystem [MemoryElementName]. Explanation: Memory has been disabled. All DIMMs. One of the DIMMs. May also be shown as 806f040c2581ffff or 0x806f040c2581ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0131 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event.
Page 403
806f0507-0302ffff • 806f050c-200101ff “Finding the UEFI diagnostic code” on page 648 806f0507-0302ffff [ProcessorElementName] has a Configuration Mismatch. Explanation: A processor configuration mismatch has occurred. May also be shown as 806f05070302ffff or 0x806f05070302ffff Severity: Error Alert Category: Critical - CPU Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0062 SNMP Trap ID: 40 Automatically notify Support: No...
Page 404
806f050c-2001ffff • 806f050c-2003ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-2001ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 405
806f050c-200401ff • 806f050c-2004ffff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 406
806f050c-2005ffff • 806f050c-2007ffff 806f050c-2005ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Reached. May also be shown as 806f050c2005ffff or 0x806f050c2005ffff Severity: Warning Alert Category: Warning - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 407
806f050c-2008ffff • 806f050c-200affff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-2008ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 408
806f050c-200bffff • 806f050c-200cffff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 409
806f050c-200dffff • 806f050c-200effff 806f050c-200dffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Reached. May also be shown as 806f050c200dffff or 0x806f050c200dffff Severity: Warning Alert Category: Warning - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 410
806f050c-200f02ff • 806f050c-2010ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-200f02ff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 411
806f050c-201102ff • 806f050c-2011ffff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 412
806f050c-201202ff • 806f050c-2013ffff 806f050c-201202ff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Reached. May also be shown as 806f050c201202ff or 0x806f050c201202ff Severity: Warning Alert Category: Warning - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 413
806f050c-2014ffff • 806f050c-2015ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-2014ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 414
806f050c-2016ffff • 806f050c-2017ffff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 415
806f050c-2018ffff • 806f050c-2019ffff 806f050c-2018ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Reached. May also be shown as 806f050c2018ffff or 0x806f050c2018ffff Severity: Warning Alert Category: Warning - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 416
806f050c-201a01ff • 806f050c-201bffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-201a01ff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 417
806f050c-201c01ff • 806f050c-201cffff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 418
806f050c-201d01ff • 806f050c-201e01ff 806f050c-201d01ff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Reached. May also be shown as 806f050c201d01ff or 0x806f050c201d01ff Severity: Warning Alert Category: Warning - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 419
806f050c-201effff • 806f050c-202001ff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-201effff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 420
806f050c-2020ffff • 806f050c-202101ff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 421
806f050c-2021ffff • 806f050c-202301ff 806f050c-2021ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Reached. May also be shown as 806f050c2021ffff or 0x806f050c2021ffff Severity: Warning Alert Category: Warning - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 422
806f050c-2023ffff • 806f050c-202502ff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-2023ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 423
806f050c-2025ffff • 806f050c-202602ff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 424
806f050c-2026ffff • 806f050c-2028ffff 806f050c-2026ffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Reached. May also be shown as 806f050c2026ffff or 0x806f050c2026ffff Severity: Warning Alert Category: Warning - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 425
806f050c-202902ff • 806f050c-202affff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-202902ff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 426
806f050c-202bffff • 806f050c-202cffff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 427
806f050c-202d02ff • 806f050c-202effff 806f050c-202d02ff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Reached. May also be shown as 806f050c202d02ff or 0x806f050c202d02ff Severity: Warning Alert Category: Warning - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event.
Page 428
806f050c-202fffff • 806f050c-2030ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f050c-202fffff Memory Logging Limit Reached for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 429
806f050c-2581ffff • 806f050d-0401ffff CIM Information: Prefix: PLAT and ID: 0144 SNMP Trap ID: 43 Automatically notify Support: Yes User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 430
806f050d-0402ffff • 806f050d-0405ffff SNMP Trap ID: 5 Automatically notify Support: No User response: Replace the hard disk drive 1 that is indicated by a lit status LED. 806f050d-0402ffff Array [ComputerSystemElementName] is in critical condition. Explanation: The RAID array is in critical condition. Immediate action is required to avoid a system outage. May also be shown as 806f050d0402ffff or 0x806f050d0402ffff Severity: Error Alert Category: Critical - Hard Disk drive...
Page 431
806f050d-0406ffff • 806f0513-2582ffff Alert Category: Critical - Hard Disk drive Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0174 SNMP Trap ID: 5 Automatically notify Support: No User response: Replace the hard disk drive 5 that is indicated by a lit status LED. 806f050d-0406ffff Array [ComputerSystemElementName] is in critical condition.
Page 432
806f052b-2101ffff • 806f0607-0302ffff Related Links: “Finding the UEFI diagnostic code” on page 648 806f052b-2101ffff Invalid or Unsupported firmware or software was detected on system [ComputerSystemElementName]. Explanation: The IMM primary firmware image has been corrupted. The IMM is running on the backup image. May also be shown as 806f052b2101ffff or 0x806f052b2101ffff Severity: Error Alert Category: Critical - Other...
Page 433
806f0607-2584ffff • 806f060d-0401ffff “Finding the UEFI diagnostic code” on page 648 806f0607-2584ffff An SM BIOS Uncorrectable CPU complex error for [ProcessorElementName] has asserted. Explanation: An SM BIOS Uncorrectable CPU complex error has been detected. All CPUs. One of CPUs. May also be shown as 806f06072584ffff or 0x806f06072584ffff Severity: Error Alert Category: Critical - CPU Serviceable: Yes...
Page 434
806f060d-0402ffff • 806f060d-0404ffff v Replace the hard disk drives that are indicated by a lit status LED on the drive. v Recreate the array. v Restore data from backup. 806f060d-0402ffff Array [ComputerSystemElementName] has failed. Explanation: The Drive 2 is part of an RAID array that is in the failed condition. To identify drives in the failed array all member drives will report this message.
Page 435
806f060d-0405ffff • 806f060d-0407ffff SNMP Trap ID: 5 Automatically notify Support: Yes User response: v Replace the hard disk drives that are indicated by a lit status LED on the drive. v Recreate the array. v Restore data from backup. 806f060d-0405ffff Array [ComputerSystemElementName] has failed.
Page 436
806f070c-2001ffff • 806f070c-2002ffff Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0176 SNMP Trap ID: 5 Automatically notify Support: Yes User response: v Replace the hard disk drives that are indicated by a lit status LED on the drive. v Recreate the array. v Restore data from backup.
Page 437
806f070c-200301ff • 806f070c-200401ff 806f070c-200301ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c200301ff or 0x806f070c200301ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 438
806f070c-2004ffff • 806f070c-2005ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-2004ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 439
806f070c-200601ff • 806f070c-2006ffff CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 440
806f070c-200701ff • 806f070c-200801ff 806f070c-200701ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c200701ff or 0x806f070c200701ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 441
806f070c-2008ffff • 806f070c-2009ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-2008ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 442
806f070c-200a01ff • 806f070c-200affff CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 443
806f070c-200b01ff • 806f070c-200c01ff 806f070c-200b01ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c200b01ff or 0x806f070c200b01ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 444
806f070c-200cffff • 806f070c-200e02ff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-200cffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected.
Page 445
806f070c-200effff • 806f070c-200fffff SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 446
806f070c-201002ff • 806f070c-2010ffff Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 447
806f070c-2011ffff • 806f070c-201302ff 806f070c-2011ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c2011ffff or 0x806f070c2011ffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 448
806f070c-2013ffff • 806f070c-2014ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-2013ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 449
806f070c-201502ff • 806f070c-2015ffff CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 450
806f070c-201602ff • 806f070c-201702ff 806f070c-201602ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c201602ff or 0x806f070c201602ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 451
806f070c-2017ffff • 806f070c-2018ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-2017ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 452
806f070c-201901ff • 806f070c-2019ffff CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 453
806f070c-201affff • 806f070c-201bffff 806f070c-201affff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c201affff or 0x806f070c201affff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 454
806f070c-201c01ff • 806f070c-201d01ff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-201c01ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 455
806f070c-201dffff • 806f070c-201effff SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 456
806f070c-201f01ff • 806f070c-201fffff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 457
806f070c-202001ff • 806f070c-2021ffff 806f070c-202001ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c202001ff or 0x806f070c202001ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 458
806f070c-202201ff • 806f070c-202301ff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-202201ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 459
806f070c-2023ffff • 806f070c-2024ffff CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 460
806f070c-202502ff • 806f070c-202602ff 806f070c-202502ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c202502ff or 0x806f070c202502ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 461
806f070c-2026ffff • 806f070c-2027ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-2026ffff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 462
806f070c-202802ff • 806f070c-2028ffff CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 463
806f070c-202902ff • 806f070c-202a02ff 806f070c-202902ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c202902ff or 0x806f070c202902ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 464
806f070c-202affff • 806f070c-202bffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-202affff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 465
806f070c-202c02ff • 806f070c-202d02ff CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 466
806f070c-202dffff • 806f070c-202e02ff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text.
Page 467
806f070c-202effff • 806f070c-202fffff 806f070c-202effff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A Memory DIMM configuration error has been detected. May also be shown as 806f070c202effff or 0x806f070c202effff Severity: Error Alert Category: Critical - Memory Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event.
Page 468
806f070c-203002ff • 806f070c-2581ffff IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response. Related Links: “Finding the UEFI diagnostic code” on page 648 806f070c-203002ff Configuration Error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 469
806f070d-0400ffff • 806f070d-0402ffff CIM Information: Prefix: PLAT and ID: 0126 SNMP Trap ID: 41 Automatically notify Support: No User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information Center for the appropriate user response.
Page 470
806f070d-0403ffff • 806f070d-0406ffff 806f070d-0403ffff Rebuild in progress for Array in system [ComputerSystemElementName]. Explanation: The array that contains Drive 3 is in the process of being rebuilt. May also be shown as 806f070d0403ffff or 0x806f070d0403ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0178 SNMP Trap ID:...
Page 471
806f070d-0407ffff • 806f072b-2201ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 806f070d-0407ffff Rebuild in progress for Array in system [ComputerSystemElementName]. Explanation: The array that contains Drive 7 is in the process of being rebuilt. May also be shown as 806f070d0407ffff or 0x806f070d0407ffff Severity: Info Alert Category: System - Other...
Page 472
806f0807-0301ffff • 806f0807-2584ffff 806f0807-0301ffff [ProcessorElementName] has been Disabled. Explanation: A Processor has been Disabled. May also be shown as 806f08070301ffff or 0x806f08070301ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0061 SNMP Trap ID: Automatically notify Support: No User response: This is a UEFI detected event.
Page 473
806f0813-2581ffff • 806f0823-2101ffff “Finding the UEFI diagnostic code” on page 648 806f0813-2581ffff An Uncorrectable Bus Error has occurred on bus [SensorElementName]. Explanation: A catastrophic system error has occurred. The system firmware will attempt to analyze the failure to determine whether the failure was due to a hardware component or a software component. May also be shown as 806f08132581ffff or 0x806f08132581ffff Severity: Error Alert Category: Critical - Other...
Page 474
806f090c-2001ffff • 806f090c-2003ffff Automatically notify Support: No User response: Information only; no action is required. 806f090c-2001ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c2001ffff or 0x806f090c2001ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22...
Page 475
806f090c-2004ffff • 806f090c-2005ffff CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 476
806f090c-2006ffff • 806f090c-2008ffff 806f090c-2006ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c2006ffff or 0x806f090c2006ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 477
806f090c-2009ffff • 806f090c-200affff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 478
806f090c-200bffff • 806f090c-200dffff 806f090c-200bffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c200bffff or 0x806f090c200bffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 479
806f090c-200effff • 806f090c-200fffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 480
806f090c-2010ffff • 806f090c-2012ffff 806f090c-2010ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c2010ffff or 0x806f090c2010ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 481
806f090c-2013ffff • 806f090c-2014ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 482
806f090c-2015ffff • 806f090c-2017ffff 806f090c-2015ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c2015ffff or 0x806f090c2015ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 483
806f090c-2018ffff • 806f090c-2019ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 484
806f090c-201affff • 806f090c-201cffff 806f090c-201affff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c201affff or 0x806f090c201affff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 485
806f090c-201dffff • 806f090c-201effff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 486
806f090c-201fffff • 806f090c-202101ff 806f090c-201fffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c201fffff or 0x806f090c201fffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 487
806f090c-2021ffff • 806f090c-2022ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 488
806f090c-2023ffff • 806f090c-2025ffff 806f090c-2023ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c2023ffff or 0x806f090c2023ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 489
806f090c-2026ffff • 806f090c-2027ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 490
806f090c-2028ffff • 806f090c-202affff 806f090c-2028ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c2028ffff or 0x806f090c2028ffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 491
806f090c-202bffff • 806f090c-202cffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 492
806f090c-202dffff • 806f090c-202fffff 806f090c-202dffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] Throttled. Explanation: Memory has been Throttled. May also be shown as 806f090c202dffff or 0x806f090c202dffff Severity: Warning Alert Category: System - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0142 SNMP Trap ID: 22 Automatically notify Support: No User response: Complete the following steps: 1.
Page 493
806f090c-2030ffff • 806f0a07-0302ffff User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 494
806f0a07-2584ffff • 806f0a0c-2001ffff Alert Category: Warning - CPU Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0038 SNMP Trap ID: 42 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan- or cooling-related issues or power-related issues.. 2.
Page 495
806f0a0c-2002ffff • 806f0a0c-2004ffff 806f0a0c-2002ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c2002ffff or 0x806f0a0c2002ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 496
806f0a0c-2005ffff • 806f0a0c-2006ffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 497
806f0a0c-2007ffff • 806f0a0c-2009ffff 806f0a0c-2007ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c2007ffff or 0x806f0a0c2007ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 498
806f0a0c-200affff • 806f0a0c-200bffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 499
806f0a0c-200cffff • 806f0a0c-200effff 806f0a0c-200cffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c200cffff or 0x806f0a0c200cffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 500
806f0a0c-200fffff • 806f0a0c-2010ffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 501
806f0a0c-2011ffff • 806f0a0c-2013ffff 806f0a0c-2011ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c2011ffff or 0x806f0a0c2011ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 502
806f0a0c-2014ffff • 806f0a0c-2015ffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 503
806f0a0c-2016ffff • 806f0a0c-2018ffff 806f0a0c-2016ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c2016ffff or 0x806f0a0c2016ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 504
806f0a0c-2019ffff • 806f0a0c-201affff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 505
806f0a0c-201bffff • 806f0a0c-201dffff 806f0a0c-201bffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c201bffff or 0x806f0a0c201bffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 506
806f0a0c-201effff • 806f0a0c-201fffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 507
806f0a0c-2020ffff • 806f0a0c-2021ffff 806f0a0c-2020ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c2020ffff or 0x806f0a0c2020ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 508
806f0a0c-2022ffff • 806f0a0c-2023ffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 509
806f0a0c-2024ffff • 806f0a0c-2026ffff 806f0a0c-2024ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c2024ffff or 0x806f0a0c2024ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 510
806f0a0c-2027ffff • 806f0a0c-2028ffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 511
806f0a0c-2029ffff • 806f0a0c-202bffff 806f0a0c-2029ffff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c2029ffff or 0x806f0a0c2029ffff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 512
806f0a0c-202cffff • 806f0a0c-202dffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 513
806f0a0c-202effff • 806f0a0c-2030ffff 806f0a0c-202effff An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: An over temperature condition for memory has been detected. May also be shown as 806f0a0c202effff or 0x806f0a0c202effff Severity: Error Alert Category: Critical - Temperature Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0146 SNMP Trap ID: 0...
Page 514
806f0a13-2401ffff • 806f0b13-0701ffff SNMP Trap ID: 0 Automatically notify Support: No User response: Complete the following steps: 1. Check the CMM or FSM event log for any fan or cooling related issues. 2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly installed.
Page 515
81010202-0701ffff • 81010701-3701ffff Alert Category: Warning - Other Serviceable: Yes CIM Information: Prefix: PLAT and ID: 0246 SNMP Trap ID: 60 Automatically notify Support: No User response: Complete the following steps: 1. AC cycle the machine 2. Remove CPU 1 and inspect the CPU socket for bent pins. 3.
Page 516
81010701-3702ffff • 81010902-0701ffff Automatically notify Support: No User response: Information only; no action is required. 81010701-3702ffff Numeric sensor [NumericSensorElementName] going high (upper non-critical) has deasserted. Explanation: The previously high inlet temperature 2 has returned to below its specified threshold. May also be shown as 810107013702ffff or 0x810107013702ffff Severity: Info Alert Category: Warning - Temperature Serviceable: No...
Page 517
81010b01-3701ffff • 81030006-2101ffff Alert Category: Critical - Voltage Serviceable: No CIM Information: Prefix: PLAT and ID: 0495 SNMP Trap ID: 1 Automatically notify Support: No User response: Information only; no action is required. 81010b01-3701ffff Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has deasserted.
Page 518
8103000f-2101ffff • 8103010d-2b81ffff 8103000f-2101ffff Sensor [SensorElementName] has asserted. Explanation: IMM Firmware is Corrupted. May also be shown as 8103000f2101ffff or 0x8103000f2101ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0508 SNMP Trap ID: Automatically notify Support: No User response: Check that the primary build level is correct and upgrade primary to latest level.
Page 519
8103010e-2581ffff • 8105010d-2b81ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0509 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. Related Links: “Removing a flash DIMM” on page 730 “Installing a flash DIMM” on page 730 “Removing a DIMM”...
Page 520
81070101-030101ff • 81070101-0302ffff Automatically notify Support: No User response: Information only; no action is required. 81070101-030101ff Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. Explanation: The previously high microprocessor 1 temperature has returned to below its specified threshold. May also be shown as 81070101030101ff or 0x81070101030101ff Severity: Info Alert Category: Warning - Temperature...
Page 521
81070101-0481ffff • 81070101-2c02ffff Alert Category: Warning - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0521 SNMP Trap ID: 12 Automatically notify Support: No User response: Information only; no action is required. 81070101-0481ffff Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. Explanation: IMM has detected that the Drive temperature has returned to normal.
Page 522
81070101-2c03ffff • 8107010d-2582ffff 81070101-2c03ffff Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. Explanation: The previously high I/O Exansion card temperature has returned to below its specified threshold. May also be shown as 810701012c03ffff or 0x810701012c03ffff Severity: Info Alert Category: Warning - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0521...
Page 523
8107010d-2b81ffff • 8107010f-2582ffff SNMP Trap ID: 60 Automatically notify Support: No User response: RAID Vol State : 8107010d-2b81ffff Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. Explanation: The IMM has detected that the Sensor deasserted. May also be shown as 8107010d2b81ffff or 0x8107010d2b81ffff Severity: Info Alert Category: Warning - Other Serviceable: No...
Page 524
81070114-2201ffff • 81070202-0701ffff Severity: Info Alert Category: Warning - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0521 SNMP Trap ID: 60 Automatically notify Support: No User response: Information only; no action is required. 81070114-2201ffff Sensor [SensorElementName] has deasserted the transition from normal to non-critical state. Explanation: The TPM Lock has returned to normal.
Page 525
8107020c-2581ffff • 8107020f-2201ffff 8107020c-2581ffff Sensor [SensorElementName] has transitioned to a less severe state from critical. Explanation: IMM has reported a SMI Lane Failed has deasserted. May also be shown as 8107020c2581ffff or 0x8107020c2581ffff Severity: Info Alert Category: Critical - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0523 SNMP Trap ID: 50...
Page 526
8107020f-2582ffff • 81070217-2c02ffff CIM Information: Prefix: PLAT and ID: 0523 SNMP Trap ID: 50 Automatically notify Support: No User response: Information only; no action is required. 8107020f-2582ffff Sensor [SensorElementName] has transitioned to a less severe state from critical. Explanation: The prior I/O resource conflict has been resolved. May also be shown as 8107020f2582ffff or 0x8107020f2582ffff Severity: Info Alert Category: Critical - Other...
Page 527
81070217-2c03ffff • 8107021b-0301ffff 81070217-2c03ffff Sensor [SensorElementName] has transitioned to a less severe state from critical. Explanation: The I/O Expansion card is no longer in a fault condition. May also be shown as 810702172c03ffff or 0x810702172c03ffff Severity: Info Alert Category: Critical - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0523 SNMP Trap ID: 50...
Page 528
8107021b-0302ffff • 81070301-0301ffff SNMP Trap ID: 50 Automatically notify Support: No User response: Information only; no action is required. 8107021b-0302ffff Sensor [SensorElementName] has transitioned to a less severe state from critical. Explanation: IMM has detected that CPU 2 has recovered from a QPI Link Error. May also be shown as 8107021b0302ffff or 0x8107021b0302ffff Severity: Info Alert Category: Critical - Other...
Page 529
81070301-0302ffff • 81070301-2c01ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0525 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 81070301-0302ffff Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state.
Page 530
81070301-2c02ffff • 81070301-2d01ffff User response: Information only; no action is required. 81070301-2c02ffff Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state. Explanation: The previously high I/O Expansion card temperature has returned below its specified threshold. May also be shown as 810703012c02ffff or 0x810703012c02ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No...
Page 531
8107030d-2582ffff • 8107030d-3030ffff Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0525 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 8107030d-2582ffff Sensor [SensorElementName] has deasserted the transition to non-recoverable from a less severe state.
Page 532
81070601-2c01ffff • 81070601-2c04ffff Automatically notify Support: No User response: ROMB Volume : 81070601-2c01ffff Sensor [SensorElementName] has deasserted the transition to non-recoverable. Explanation: The previously high I/O Expansion card temperature has returned below its specified threshold. May also be shown as 810706012c01ffff or 0x810706012c01ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No...
Page 533
8107060f-2201ffff • 81070617-2c02ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0531 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 8107060f-2201ffff Sensor [SensorElementName] has deasserted the transition to non-recoverable. Explanation: BOFM Config Sensor has transitioned to non-recoverable has deasserted. May also be shown as 8107060f2201ffff or 0x8107060f2201ffff Severity: Info Alert Category: Critical - Other...
Page 534
81070617-2c03ffff • 810b010c-2581ffff 81070617-2c03ffff Sensor [SensorElementName] has deasserted the transition to non-recoverable. Explanation: The I/O expansion adapter in I/O expansion connector 3 no longer reports a non-recoverable condition. May also be shown as 810706172c03ffff or 0x810706172c03ffff Severity: Info Alert Category: Critical - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0531 SNMP Trap ID: 50...
Page 535
810b030c-2581ffff • 816f0007-0301ffff CIM Information: Prefix: PLAT and ID: 0803 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 810b030c-2581ffff Non-redundant:Sufficient Resources from Redundancy Degraded or Fully Redundant for [RedundancySetElementName] has deasserted. Explanation: Memory component group (Backup Memory) has regained its redundancy. May also be shown as 810b030c2581ffff or 0x810b030c2581ffff Severity: Info Alert Category: Warning - Memory...
Page 536
816f0007-0302ffff • 816f000d-0401ffff 816f0007-0302ffff [ProcessorElementName] has Recovered from IERR. Explanation: A processor has recovered - IERR Condition. May also be shown as 816f00070302ffff or 0x816f00070302ffff Severity: Info Alert Category: Critical - CPU Serviceable: No CIM Information: Prefix: PLAT and ID: 0043 SNMP Trap ID: 40 Automatically notify Support: No User response: Information only;...
Page 537
816f000d-0402ffff • 816f000d-0403ffff Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0163 SNMP Trap ID: 5 Automatically notify Support: No User response: v If drive was intentionally removed, no action required. v Make sure that the drive properly seated. v If drive is properly seated, replace the drive.
Page 538
816f000d-0404ffff • 816f000d-0406ffff 816f000d-0404ffff The Drive [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. Explanation: Presence of drive 4 is no longer detected. If hard drive is absent from drive bay a filler is required. May also be shown as 816f000d0404ffff or 0x816f000d0404ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No...
Page 539
816f000d-0407ffff • 816f0013-1701ffff v If drive is properly seated, replace the drive. 816f000d-0407ffff The [StorageVolumeElementName] has been removed from unit [PhysicalPackageElementName]. Explanation: Presence of drive 7 is no longer detected. If hard drive is absent from drive bay a filler is required. May also be shown as 816f000d0407ffff or 0x816f000d0407ffff Severity: Info Alert Category: Critical - Hard Disk drive...
Page 540
816f0021-1201ffff • 816f0028-2101ffff 816f0021-1201ffff Fault condition removed on slot [PhysicalConnectorElementName] on system [ComputerSystemElementName]. Explanation: The SMP scaling connector in the system has been removed. May also be shown as 816f00211201ffff or 0x816f00211201ffff Severity: Info Alert Category: Critical - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0331 SNMP Trap ID: 50 Automatically notify Support: No...
Page 541
816f0107-0301ffff • 816f0107-2584ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0399 SNMP Trap ID: 60 Automatically notify Support: No User response: Information Only; no action is required. 816f0107-0301ffff An Over-Temperature Condition has been removed on [ProcessorElementName]. Explanation: The microprocessor 1 temperature has returned to below the critical level. May also be shown as 816f01070301ffff or 0x816f01070301ffff Severity: Info Alert Category: Critical - Temperature...
Page 542
816f010c-2001ffff • 816f010c-2004ffff 816f010c-2001ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c2001ffff or 0x816f010c2001ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 543
816f010c-2005ffff • 816f010c-2007ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f010c-2005ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c2005ffff or 0x816f010c2005ffff Severity: Info Alert Category: Critical - Memory...
Page 544
816f010c-2008ffff • 816f010c-200bffff 816f010c-2008ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c2008ffff or 0x816f010c2008ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 545
816f010c-200cffff • 816f010c-200effff Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f010c-200cffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c200cffff or 0x816f010c200cffff Severity: Info Alert Category: Critical - Memory...
Page 546
816f010c-200fffff • 816f010c-2012ffff 816f010c-200fffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c200fffff or 0x816f010c200fffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 547
816f010c-2013ffff • 816f010c-2015ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f010c-2013ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c2013ffff or 0x816f010c2013ffff Severity: Info Alert Category: Critical - Memory...
Page 548
816f010c-2016ffff • 816f010c-2019ffff 816f010c-2016ffff Uncorrectable error recovery detected for DIMM 22 on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c2016ffff or 0x816f010c2016ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 549
816f010c-201affff • 816f010c-201cffff CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f010c-201affff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c201affff or 0x816f010c201affff Severity: Info Alert Category: Critical - Memory...
Page 550
816f010c-201dffff • 816f010c-2020ffff 816f010c-201dffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c201dffff or 0x816f010c201dffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 551
816f010c-2021ffff • 816f010c-2023ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f010c-2021ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c2021ffff or 0x816f010c2021ffff Severity: Info Alert Category: Critical - Memory...
Page 552
816f010c-2024ffff • 816f010c-2027ffff 816f010c-2024ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c2024ffff or 0x816f010c2024ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 553
816f010c-2028ffff • 816f010c-202affff Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f010c-2028ffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c2028ffff or 0x816f010c2028ffff Severity: Info Alert Category: Critical - Memory...
Page 554
816f010c-202bffff • 816f010c-202effff 816f010c-202bffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c202bffff or 0x816f010c202bffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 555
816f010c-202fffff • 816f010c-2581ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0139 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f010c-202fffff Uncorrectable error recovery detected for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: A memory uncorrectable error has recovered. May also be shown as 816f010c202fffff or 0x816f010c202fffff Severity: Info Alert Category: Critical - Memory...
Page 556
816f010d-0400ffff • 816f010d-0403ffff 816f010d-0400ffff The [StorageVolumeElementName] has been enabled. Explanation: The previously disabled drive 0 has been enabled. May also be shown as 816f010d0400ffff or 0x816f010d0400ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0167 SNMP Trap ID: 5 Automatically notify Support: No User response: Information only;...
Page 557
816f010d-0404ffff • 816f010d-0407ffff SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 816f010d-0404ffff The [StorageVolumeElementName] has been enabled. Explanation: The previously disabled drive 4 has been enabled. May also be shown as 816f010d0404ffff or 0x816f010d0404ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No...
Page 558
816f010d-2b81ffff • 816f0207-0301ffff Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0167 SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 816f010d-2b81ffff The [StorageVolumeElementName] has been enabled. Explanation: A drive was Enabled.
Page 559
816f0207-0302ffff • 816f020d-0401ffff 816f0207-0302ffff [ProcessorElementName] has Recovered from FRB1/BIST condition. Explanation: A processor has Recovered - FRB1/BIST condition. May also be shown as 816f02070302ffff or 0x816f02070302ffff Severity: Info Alert Category: Critical - CPU Serviceable: No CIM Information: Prefix: PLAT and ID: 0045 SNMP Trap ID: 40 Automatically notify Support: No User response: Information only;...
Page 560
816f020d-0402ffff • 816f020d-0404ffff CIM Information: Prefix: PLAT and ID: 0169 SNMP Trap ID: 27 Automatically notify Support: No User response: Information only; no action is required. 816f020d-0402ffff Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. Explanation: The predicted failure for Drive 2 no longer exists. May also be shown as 816f020d0402ffff or 0x816f020d0402ffff Severity: Info Alert Category: System - Predicted Failure...
Page 561
816f020d-0405ffff • 816f020d-2b81ffff 816f020d-0405ffff Failure no longer Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. Explanation: The predicted failure for Drive 5 no longer exists. May also be shown as 816f020d0405ffff or 0x816f020d0405ffff Severity: Info Alert Category: System - Predicted Failure Serviceable: No CIM Information: Prefix: PLAT and ID: 0169 SNMP Trap ID: 27 Automatically notify Support: No...
Page 562
816f0221-1201ffff • 816f030c-2001ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0169 SNMP Trap ID: 27 Automatically notify Support: No User response: Information only; no action is required. 816f0221-1201ffff Slot [PhysicalConnectorElementName] empty for system [ComputerSystemElementName]. Explanation: An SMP connector has been removed from the system. May also be shown as 816f02211201ffff or 0x816f02211201ffff Severity: Info Alert Category: System - Other...
Page 563
816f030c-2002ffff • 816f030c-2005ffff 816f030c-2002ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2002ffff or 0x816f030c2002ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
Page 564
816f030c-2006ffff • 816f030c-2008ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f030c-2006ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2006ffff or 0x816f030c2006ffff Severity: Info Alert Category: Critical - Memory...
Page 565
816f030c-2009ffff • 816f030c-200cffff 816f030c-2009ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2009ffff or 0x816f030c2009ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
Page 566
816f030c-200dffff • 816f030c-200fffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f030c-200dffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c200dffff or 0x816f030c200dffff Severity: Info Alert Category: Critical - Memory...
Page 567
816f030c-2010ffff • 816f030c-2013ffff 816f030c-2010ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2010ffff or 0x816f030c2010ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
Page 568
816f030c-2014ffff • 816f030c-2016ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f030c-2014ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2014ffff or 0x816f030c2014ffff Severity: Info Alert Category: Critical - Memory...
Page 569
816f030c-2017ffff • 816f030c-201affff 816f030c-2017ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2017ffff or 0x816f030c2017ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
Page 570
816f030c-201bffff • 816f030c-201dffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f030c-201bffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c201bffff or 0x816f030c201bffff Severity: Info Alert Category: Critical - Memory...
Page 571
816f030c-201effff • 816f030c-2021ffff 816f030c-201effff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c201effff or 0x816f030c201effff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
Page 572
816f030c-2022ffff • 816f030c-2024ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f030c-2022ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2022ffff or 0x816f030c2022ffff Severity: Info Alert Category: Critical - Memory...
Page 573
816f030c-2025ffff • 816f030c-2028ffff 816f030c-2025ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2025ffff or 0x816f030c2025ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
Page 574
816f030c-2029ffff • 816f030c-202bffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f030c-2029ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2029ffff or 0x816f030c2029ffff Severity: Info Alert Category: Critical - Memory...
Page 575
816f030c-202cffff • 816f030c-202fffff 816f030c-202cffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c202cffff or 0x816f030c202cffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No...
Page 576
816f030c-2030ffff • 816f030d-0400ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0137 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f030c-2030ffff Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName] has recovered. Explanation: A Memory Scrub failure detected during boot has recovered. May also be shown as 816f030c2030ffff or 0x816f030c2030ffff Severity: Info Alert Category: Critical - Memory...
Page 577
816f030d-0401ffff • 816f030d-0404ffff 816f030d-0401ffff Hot spare disabled for [ComputerSystemElementName]. Explanation: A hot spare drive is not available. May also be shown as 816f030d0401ffff or 0x816f030d0401ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0171 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 578
816f030d-0405ffff • 816f0313-1701ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f030d-0405ffff Hot spare disabled for [ComputerSystemElementName]. Explanation: A hot spare drive is not available. May also be shown as 816f030d0405ffff or 0x816f030d0405ffff Severity: Info Alert Category: System - Other Serviceable: No...
Page 579
816f032b-2101ffff • 816f040c-2002ffff Alert Category: Critical - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0230 SNMP Trap ID: 50 Automatically notify Support: No User response: Information only; no action is required. 816f032b-2101ffff The firmware or software on system [ComputerSystemElementName]are compatible. Explanation: The Firmware and Software are compatibile.
Page 580
816f040c-2003ffff • 816f040c-2006ffff 816f040c-2003ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c2003ffff or 0x816f040c2003ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 581
816f040c-2007ffff • 816f040c-200affff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f040c-2007ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c2007ffff or 0x816f040c2007ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID:...
Page 582
816f040c-200bffff • 816f040c-200dffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f040c-200bffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c200bffff or 0x816f040c200bffff Severity: Info Alert Category: System - Other...
Page 583
816f040c-200effff • 816f040c-2011ffff 816f040c-200effff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c200effff or 0x816f040c200effff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 584
816f040c-2012ffff • 816f040c-2015ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f040c-2012ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c2012ffff or 0x816f040c2012ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID:...
Page 585
816f040c-2016ffff • 816f040c-2018ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f040c-2016ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c2016ffff or 0x816f040c2016ffff Severity: Info Alert Category: System - Other...
Page 586
816f040c-2019ffff • 816f040c-201cffff 816f040c-2019ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c2019ffff or 0x816f040c2019ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 587
816f040c-201dffff • 816f040c-2020ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f040c-201dffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c201dffff or 0x816f040c201dffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID:...
Page 588
816f040c-2021ffff • 816f040c-2023ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f040c-2021ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c2021ffff or 0x816f040c2021ffff Severity: Info Alert Category: System - Other...
Page 589
816f040c-2024ffff • 816f040c-2027ffff 816f040c-2024ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c2024ffff or 0x816f040c2024ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 590
816f040c-2028ffff • 816f040c-202bffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f040c-2028ffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c2028ffff or 0x816f040c2028ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID:...
Page 591
816f040c-202cffff • 816f040c-202effff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f040c-202cffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c202cffff or 0x816f040c202cffff Severity: Info Alert Category: System - Other...
Page 592
816f040c-202fffff • 816f0413-2582ffff 816f040c-202fffff [PhysicalMemoryElementName] Enabled on Subsystem [MemoryElementName]. Explanation: Memory has been enabled. May also be shown as 816f040c202fffff or 0x816f040c202fffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0130 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 593
816f0507-0301ffff • 816f050c-2001ffff SNMP Trap ID: 50 Automatically notify Support: No User response: Information only; no action is required. 816f0507-0301ffff [ProcessorElementName] has Recovered from a Configuration Mismatch. Explanation: A Processor Configuration Mismatch has recovered. May also be shown as 816f05070301ffff or 0x816f05070301ffff Severity: Info Alert Category: Critical - CPU Serviceable: No...
Page 594
816f050c-2002ffff • 816f050c-2004ffff Severity: Info Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only; no action is required. 816f050c-2002ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 595
816f050c-2005ffff • 816f050c-2008ffff User response: Information only; no action is required. 816f050c-2005ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c2005ffff or 0x816f050c2005ffff Severity: Info Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43...
Page 596
816f050c-2009ffff • 816f050c-200bffff Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only; no action is required. 816f050c-2009ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 597
816f050c-200cffff • 816f050c-200fffff 816f050c-200cffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c200cffff or 0x816f050c200cffff Severity: Info Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only;...
Page 598
816f050c-2010ffff • 816f050c-2012ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only; no action is required. 816f050c-2010ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c2010ffff or 0x816f050c2010ffff Severity: Info Alert Category: Warning - Memory...
Page 599
816f050c-2013ffff • 816f050c-2016ffff 816f050c-2013ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c2013ffff or 0x816f050c2013ffff Severity: Info Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only;...
Page 600
816f050c-2017ffff • 816f050c-2019ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only; no action is required. 816f050c-2017ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c2017ffff or 0x816f050c2017ffff Severity: Info Alert Category: Warning - Memory...
Page 601
816f050c-201affff • 816f050c-201dffff 816f050c-201affff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c201affff or 0x816f050c201affff Severity: Info Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only;...
Page 602
816f050c-201effff • 816f050c-2020ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only; no action is required. 816f050c-201effff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c201effff or 0x816f050c201effff Severity: Info Alert Category: Warning - Memory...
Page 603
816f050c-2021ffff • 816f050c-2024ffff 816f050c-2021ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c2021ffff or 0x816f050c2021ffff Severity: Info Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only;...
Page 604
816f050c-2025ffff • 816f050c-2027ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only; no action is required. 816f050c-2025ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c2025ffff or 0x816f050c2025ffff Severity: Info Alert Category: Warning - Memory...
Page 605
816f050c-2028ffff • 816f050c-202bffff 816f050c-2028ffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c2028ffff or 0x816f050c2028ffff Severity: Info Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only;...
Page 606
816f050c-202cffff • 816f050c-202effff Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only; no action is required. 816f050c-202cffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c202cffff or 0x816f050c202cffff Severity: Info Alert Category: Warning - Memory...
Page 607
816f050c-202fffff • 816f050d-0400ffff 816f050c-202fffff Memory Logging Limit Removed for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: The Memory Logging Limit has been Removed. May also be shown as 816f050c202fffff or 0x816f050c202fffff Severity: Info Alert Category: Warning - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0145 SNMP Trap ID: 43 Automatically notify Support: No User response: Information only;...
Page 608
816f050d-0401ffff • 816f050d-0403ffff CIM Information: Prefix: PLAT and ID: 0175 SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 816f050d-0401ffff Critical Array [ComputerSystemElementName] has deasserted. Explanation: The RAID array (Drive 1) is no longer in a critical condition. May also be shown as 816f050d0401ffff or 0x816f050d0401ffff Severity: Info Alert Category: Critical - Hard Disk drive...
Page 609
816f050d-0404ffff • 816f050d-0407ffff 816f050d-0404ffff Critical Array [ComputerSystemElementName] has deasserted. Explanation: The RAID array (Drive 4) is no longer in a critical condition. May also be shown as 816f050d0404ffff or 0x816f050d0404ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0175 SNMP Trap ID: 5 Automatically notify Support: No...
Page 610
816f0513-2582ffff • 816f0607-2584ffff SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 816f0513-2582ffff A PCI SERR on system [ComputerSystemElementName] has deasserted. Explanation: A PCI System Error (SERR) has recovered. All PCI Error. One of PCI Error. May also be shown as 816f05132582ffff or 0x816f05132582ffff Severity: Info Alert Category: Critical - Other...
Page 611
816f060d-0400ffff • 816f060d-0402ffff Alert Category: Critical - CPU Serviceable: No CIM Information: Prefix: PLAT and ID: 0817 SNMP Trap ID: 40 Automatically notify Support: No User response: Information only; no action is required. 816f060d-0400ffff Array in system [ComputerSystemElementName] has been restored. Explanation: The failed RAID array (Drive 0) has been restored.
Page 612
816f060d-0403ffff • 816f060d-0406ffff 816f060d-0403ffff Array in system [ComputerSystemElementName] has been restored. Explanation: The failed RAID array (Drive 3) has been restored. May also be shown as 816f060d0403ffff or 0x816f060d0403ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No CIM Information: Prefix: PLAT and ID: 0177 SNMP Trap ID: 5 Automatically notify Support: No...
Page 613
816f060d-0407ffff • 816f070c-2002ffff SNMP Trap ID: 5 Automatically notify Support: No User response: Information only; no action is required. 816f060d-0407ffff Array in system [ComputerSystemElementName] has been restored. Explanation: The failed RAID array (Drive 7) has been restored. May also be shown as 816f060d0407ffff or 0x816f060d0407ffff Severity: Info Alert Category: Critical - Hard Disk drive Serviceable: No...
Page 614
816f070c-2003ffff • 816f070c-2006ffff 816f070c-2003ffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c2003ffff or 0x816f070c2003ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 615
816f070c-2007ffff • 816f070c-2009ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f070c-2007ffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c2007ffff or 0x816f070c2007ffff Severity: Info Alert Category: Critical - Memory...
Page 616
816f070c-200affff • 816f070c-200dffff 816f070c-200affff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c200affff or 0x816f070c200affff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 617
816f070c-200effff • 816f070c-2010ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f070c-200effff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c200effff or 0x816f070c200effff Severity: Info Alert Category: Critical - Memory...
Page 618
816f070c-2011ffff • 816f070c-2014ffff 816f070c-2011ffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c2011ffff or 0x816f070c2011ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 619
816f070c-2015ffff • 816f070c-2017ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f070c-2015ffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c2015ffff or 0x816f070c2015ffff Severity: Info Alert Category: Critical - Memory...
Page 620
816f070c-2018ffff • 816f070c-201bffff 816f070c-2018ffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c2018ffff or 0x816f070c2018ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 621
816f070c-201cffff • 816f070c-201effff Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f070c-201cffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c201cffff or 0x816f070c201cffff Severity: Info Alert Category: Critical - Memory...
Page 622
816f070c-201fffff • 816f070c-2022ffff 816f070c-201fffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c201fffff or 0x816f070c201fffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 623
816f070c-2023ffff • 816f070c-2025ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f070c-2023ffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c2023ffff or 0x816f070c2023ffff Severity: Info Alert Category: Critical - Memory...
Page 624
816f070c-2026ffff • 816f070c-2029ffff 816f070c-2026ffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c2026ffff or 0x816f070c2026ffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 625
816f070c-202affff • 816f070c-202cffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f070c-202affff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c202affff or 0x816f070c202affff Severity: Info Alert Category: Critical - Memory...
Page 626
816f070c-202dffff • 816f070c-2030ffff 816f070c-202dffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. May also be shown as 816f070c202dffff or 0x816f070c202dffff Severity: Info Alert Category: Critical - Memory Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only;...
Page 627
816f070c-2581ffff • 816f070d-0401ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0127 SNMP Trap ID: 41 Automatically notify Support: No User response: Information only; no action is required. 816f070c-2581ffff Configuration error for [PhysicalMemoryElementName] on Subsystem [MemoryElementName]has deasserted. Explanation: A memory DIMM configuration error has recovered. All DIMMs. One of the DIMMs. May also be shown as 816f070c2581ffff or 0x816f070c2581ffff Severity: Info Alert Category: Critical - Memory...
Page 628
816f070d-0402ffff • 816f070d-0405ffff 816f070d-0402ffff Rebuild completed for Array in system [ComputerSystemElementName]. Explanation: The rebuild of the RAID array (Drive 2) has completed. May also be shown as 816f070d0402ffff or 0x816f070d0402ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0179 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 629
816f070d-0406ffff • 816f0807-0302ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f070d-0406ffff Rebuild completed for Array in system [ComputerSystemElementName]. Explanation: The rebuild of the RAID array (Drive 6) has completed. May also be shown as 816f070d0406ffff or 0x816f070d0406ffff Severity: Info Alert Category: System - Other Serviceable: No...
Page 630
816f0807-2584ffff • 816f0813-2584ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0060 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f0807-2584ffff [ProcessorElementName] has been Enabled. Explanation: A processor has been enabled. All CPUs. One of CPUs. May also be shown as 816f08072584ffff or 0x816f08072584ffff Severity: Info Alert Category: System - Other...
Page 631
816f090c-2001ffff • 816f090c-2004ffff 816f090c-2001ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 1 throttling has been turned off. May also be shown as 816f090c2001ffff or 0x816f090c2001ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 632
816f090c-2005ffff • 816f090c-2008ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-2005ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 5 throttling has been turned off. May also be shown as 816f090c2005ffff or 0x816f090c2005ffff Severity: Info Alert Category: System - Other Serviceable: No...
Page 633
816f090c-2009ffff • 816f090c-200bffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-2009ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 9 throttling has been turned off.
Page 634
816f090c-200cffff • 816f090c-200fffff 816f090c-200cffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 12 throttling has been turned off. May also be shown as 816f090c200cffff or 0x816f090c200cffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 635
816f090c-2010ffff • 816f090c-2013ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-2010ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 16 throttling has been turned off. May also be shown as 816f090c2010ffff or 0x816f090c2010ffff Severity: Info Alert Category: System - Other Serviceable: No...
Page 636
816f090c-2014ffff • 816f090c-2016ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-2014ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 20 throttling has been turned off.
Page 637
816f090c-2017ffff • 816f090c-201affff 816f090c-2017ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 23 throttling has been turned off. May also be shown as 816f090c2017ffff or 0x816f090c2017ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 638
816f090c-201bffff • 816f090c-201effff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-201bffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 27 throttling has been turned off. May also be shown as 816f090c201bffff or 0x816f090c201bffff Severity: Info Alert Category: System - Other Serviceable: No...
Page 639
816f090c-201fffff • 816f090c-2021ffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-201fffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 31 throttling has been turned off.
Page 640
816f090c-2022ffff • 816f090c-2025ffff 816f090c-2022ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 34 throttling has been turned off. May also be shown as 816f090c2022ffff or 0x816f090c2022ffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 641
816f090c-2026ffff • 816f090c-2029ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-2026ffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 38 throttling has been turned off. May also be shown as 816f090c2026ffff or 0x816f090c2026ffff Severity: Info Alert Category: System - Other Serviceable: No...
Page 642
816f090c-202affff • 816f090c-202cffff Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f090c-202affff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 42 throttling has been turned off.
Page 643
816f090c-202dffff • 816f090c-2030ffff 816f090c-202dffff [PhysicalMemoryElementName] on Subsystem [MemoryElementName] is no longer Throttled. Explanation: Memory DIMM 45 throttling has been turned off. May also be shown as 816f090c202dffff or 0x816f090c202dffff Severity: Info Alert Category: System - Other Serviceable: No CIM Information: Prefix: PLAT and ID: 0143 SNMP Trap ID: Automatically notify Support: No User response: Information only;...
Page 644
816f0a07-0301ffff • 816f0a0c-2001ffff SNMP Trap ID: Automatically notify Support: No User response: Information only; no action is required. 816f0a07-0301ffff The Processor [ProcessorElementName] is no longer operating in a Degraded State. Explanation: The microprocessor 1 is no longer being throttled. (or ... has been turned off.) May also be shown as 816f0a070301ffff or 0x816f0a070301ffff Severity: Info Alert Category: Warning - CPU...
Page 645
816f0a0c-2002ffff • 816f0a0c-2004ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 816f0a0c-2002ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 646
816f0a0c-2005ffff • 816f0a0c-2008ffff User response: Information only; no action is required. 816f0a0c-2005ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 5 is no longer in an over-temperature condition. May also be shown as 816f0a0c2005ffff or 0x816f0a0c2005ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No...
Page 647
816f0a0c-2009ffff • 816f0a0c-200bffff Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 816f0a0c-2009ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Page 648
816f0a0c-200cffff • 816f0a0c-200fffff 816f0a0c-200cffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 12 is no longer in an over-temperature condition. May also be shown as 816f0a0c200cffff or 0x816f0a0c200cffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
Page 649
816f0a0c-2010ffff • 816f0a0c-2012ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 816f0a0c-2010ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 16 is no longer in an over-temperature condition.
Page 650
816f0a0c-2013ffff • 816f0a0c-2016ffff 816f0a0c-2013ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 19 is no longer in an over-temperature condition. May also be shown as 816f0a0c2013ffff or 0x816f0a0c2013ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
Page 651
816f0a0c-2017ffff • 816f0a0c-2019ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 816f0a0c-2017ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 23 is no longer in an over-temperature condition.
Page 652
816f0a0c-201affff • 816f0a0c-201dffff 816f0a0c-201affff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 26 is no longer in an over-temperature condition. May also be shown as 816f0a0c201affff or 0x816f0a0c201affff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
Page 653
816f0a0c-201effff • 816f0a0c-2020ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 816f0a0c-201effff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 30 is no longer in an over-temperature condition.
Page 654
816f0a0c-2021ffff • 816f0a0c-2024ffff 816f0a0c-2021ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 33 is no longer in an over-temperature condition. May also be shown as 816f0a0c2021ffff or 0x816f0a0c2021ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
Page 655
816f0a0c-2025ffff • 816f0a0c-2027ffff Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 816f0a0c-2025ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 37 is no longer in an over-temperature condition.
Page 656
816f0a0c-2028ffff • 816f0a0c-202bffff 816f0a0c-2028ffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 40 is no longer in an over-temperature condition. May also be shown as 816f0a0c2028ffff or 0x816f0a0c2028ffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
Page 657
816f0a0c-202cffff • 816f0a0c-202effff Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0 Automatically notify Support: No User response: Information only; no action is required. 816f0a0c-202cffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 44 is no longer in an over-temperature condition.
Page 658
816f0a0c-202fffff • 816f0a13-2582ffff 816f0a0c-202fffff An Over-Temperature Condition has been removed on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. Explanation: Memory DIMM 47 is no longer in an over-temperature condition. May also be shown as 816f0a0c202fffff or 0x816f0a0c202fffff Severity: Info Alert Category: Critical - Temperature Serviceable: No CIM Information: Prefix: PLAT and ID: 0147 SNMP Trap ID: 0...
816f0b13-0701ffff CIM Information: Prefix: PLAT and ID: 0245 SNMP Trap ID: 50 Automatically notify Support: No User response: Information only; no action is required. 816f0b13-0701ffff Bus [SensorElementName] is no longer operating in a degraded state. Explanation: IMM has detected the DMI Bus is No Longer Degraded. May also be shown as 816f0b130701ffff or 0x816f0b130701ffff Severity: Info Alert Category: Warning - Other...
Page 660
v System: The event is the result of a system error or a configuration change. device component is the specific device in the compute node that caused the event to be generated. User response The actions that you should perform to resolve the event. Perform the steps listed in this section in the order shown until the problem is solved.
Page 661
I.11002 • I.18006 Note: Not all events have a UEFI diagnostic code associated with the event. Table 8. Finding the UEFI diagnostic code Interface to the UEFI diagnostic code Action Logged on to Flex System Manager 1. Go to the Problems (Active Status) view management software (if installed) and click the name of the problem.
Page 662
I.18007 • I.1800A If this is a newly installed option, ensure that matching Processor CPUs are installed in the correct Processor CPU sockets according to the service information for this product Check IBM support site for an applicable retain tipservice bulletin or firmware update that applies to this Processor error.
Page 663
I.1800B • I.1800E Verify that matching Processors are installed in the correct Processor sockets according to the service information for this product. Correct any mismatch found. Check IBM support site for an applicable service bulletin or firmware update that applies to this processor error. (Trained Service technician only) Replace the Processor.
Page 664
I.1800F • I.2018003 I.1800F [I.1800F] Explanation: A processor family mismatch has been detected for one or more processor packages. Processors have mismatched Family Severity: Error User response: Complete the following steps: Verify that matching Processors are installed in the correct Processor sockets according to the service information for this product Check IBM support site for an applicable service bulletin or firmware update that applies to this Processor error.
Page 665
I.3048005 • I.3818003 I.3048005 [I.3048005] Explanation: UEFI has booted from the backup flash bank. Booting Backup UEFI Image Severity: Info User response: Complete the following steps: Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Reflash Primary UEFI image.
Page 666
I.3868000 • S.1100B I.3868000 [I.3868000] Explanation: BOFM: System reset performed to reset adapters. BOFM: System reset performed to reset adapters Severity: Info User response: Complete the following steps: No user required for this event. This is for informational purposes only. I.3868003 [I.3868003] Explanation: BOFM: Configuration too large for compatibility mode.
Page 667
S.1100C • S.2011001 Check IBM support site for an applicable service bulletin or UEFI firmware update that applies to this Processor error. Reboot system. If problem persists escalate to the next level of support. S.1100C [S.1100C] Explanation: An uncorrectable error has been detected on processor %. Severity: Error User response: Complete the following steps: Check IBM support site for an applicable service bulletin or UEFI firmware update that applies to this error.
Page 668
S.2018001 • S.3030007 S.2018001 [S.2018001] Explanation: An Uncorrected PCIe Error has Occurred at Bus % Device % Function %. The Vendor ID for the device is % and the Device ID is %. PCIe Uncorrected Error Detected Severity: Error User response: Complete the following steps: Check IBM support site for an applicable device driver, firmware update, version of service information for this product or other information that applies to this error.
Page 669
S.3040007 • S.3060007 S.3040007 [S.3040007] Explanation: A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault Detected, System halted Severity: Error User response: Complete the following steps: Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Reflash UEFI image.
Page 670
S.3070007 • S.3828001 S.3070007 [S.3070007] Explanation: A firmware fault has been detected in the UEFI image. Internal UEFI Firmware Fault Detected, System halted Severity: Error User response: Complete the following steps: Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Reflash UEFI image.
Page 671
S.3828002 • S.51009 S.3828002 [S.3828002] Explanation: Timed Out waiting on boot permission from Management Module: System Halted Timed Out waiting on boot permission from Management Module: System Halted Severity: Error User response: Complete the following steps: Check IMM log Review power policies and system configuration settings in the IMM. S.51003 [S.51003] Explanation: An uncorrectable memory error was detected in DIMM slot % on rank %.
Page 672
S.58008 • S.68005 If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that all DIMM connectors are enabled using the Setup utility or the Advanced Settings Utility (ASU). Re-Install all DIMMs verifying the correct population sequence, according to the service information for this product.
Page 673
S.680B8 • W.3058009 (Trained service technician only) Replace Processor. Inspect Processor socket for foreign debris or damage. If debris is found, remove debris. If socket is damaged, replace the system board first. (Trained Service technician only) If error recurs, replace the system board. S.680B8 [S.680B8] Explanation: Internal QPI Link Failure Detected.
Page 674
W.305800A • W.3808000 Go to F1 Setup > System Settings > Settings > Driver Health Status List and find a driver/controller reporting Configuration Required status. Search for the driver menu from System Settings and change settings appropriately. Save settings and restart system. W.305800A [W.305800A] Explanation: DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller.
Page 675
W.3808002 • W.381800D Check the IMM network cables and configuration. 2. AC cycle the system. Check IBM support site for an applicable service bulletin or firmware update that applies to this error. Reflash IMM Firmware. (Trained Service technician only) Replace the system board. W.3808002 [W.3808002] Explanation: An error occurred while saving UEFI settings to the IMM.
Page 676
W.3868001 • W.58001 User response: Complete the following steps: Complete any administrative tasks requiring the TPM physical presence switch to be in the "ON" position.. Restore the physical presence switch to the "OFF" position and reboot the system. (Trained Service technician only) Replace the system board. W.3868001 [W.3868001] Explanation: BOFM: Reset loop avoided - Multiple resets not allowed.
Page 677
W.58002 • W.580A1 User response: Complete the following steps: If the node has recently been installed, moved, serviced, or upgraded, verify that the DIMM is properly seated and visually verify that there is no foreign material in any DIMM connector on that memory channel. If either of these conditions is found, correct and retry with the same DIMM.
Page 678
W.580A2 • W.580B1 If a DIMM connector error LED is lit, resolve the failure. Make sure that the DIMM connectors are correctly populated for mirroring mode, according to the service information for this product. W.580A2 [W.580A2] Explanation: Invalid memory configuration for Sparing Mode. Please correct memory configuration. Unsupported DIMM Population for Spare Mode Severity: Error User response: Complete the following steps:...
W.68002 • W.680B6 (Trained service technician only) Remove affected Processor and inspect Processor socket pins for damaged or mis-aligned pins. If damage is found, replace the system board. W.68002 [W.68002] Explanation: A CMOS battery error has been detected CMOS Battery Fault Severity: Error User response: Complete the following steps: If the system was recently Installed, Moved, or Serviced, make sure the battery is properly seated.
Page 680
089-000-xxx • 089-802-xxx do not replace a CRU. See the description for Warning in “Diagnostic text messages” on page 71 for more information. Microprocessor test Use this information to diagnose and solve microprocessor test errors. Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. See Chapter 5, “Parts listing, Types 7903 and 4259,” on page 59 to determine which components are Tier 1 customer replaceable units (CRUs) and which components are field replaceable units (FRUs).
Embedded hypervisor is not in the Boot List This issue is related to a hypervisor key If the compute node has recently been installed, moved, or serviced, or if this is the first time the embedded hypervisor is being used, make sure that the device is connected properly and that there is no physical damage to the connectors.
Page 683
Cannot communicate with the I/O module Use the information in this section to troubleshoot the compute node when you cannot communicate with the I/O module. 1. Make sure that all ports in the connection path are enabled and that you can ping the I/O module.
Page 684
b. All cables between the I/O module and the network device (switch or router) are correctly connected and secure, and that the activity LEDs are lit on the applicable ports. 3. From the compute node operating system, verify the network settings, such as IP address, subnet mask (if using IPv4), DHCP settings, and vLAN settings, to ensure that the settings match the settings of the network device.
Page 685
1. If you have just updated the firmware for one or more devices in the chassis (I/O module, CMM, etc), install the previous level of firmware. 2. Make sure that: a. The I/O module is powered on and the appropriate ports are enabled on the I/O module.
Page 686
Cannot log in Use the information in this section to troubleshoot the compute node when you cannot log in to the management node, the Chassis Management Module (CMM), or the I/O module. Cannot log into the CMM: Use the information in this section to troubleshoot the compute node when you cannot log in to the Chassis Management Module (CMM).
Page 687
the IP address that is displayed in the Setup utility. If it is not the same IP address, configure the IMM network settings correctly or reset the IMM to automatically acquire a new IP address. 7. Check the IBM Support Portal for any firmware updates that might apply to this problem.
Page 688
a. Force the link/duplex speed. b. Check the connectors on the CMM to make sure that no pins are bent. c. Check the connectors on the chassis midplane to make sure that no pins are bent. d. Remove the CMM and install a working CMM in the same bay. e.
Page 689
Multiple nodes cannot ping the I/O module: Use the information in this section to troubleshoot multiple nodes that cannot ping the I/O module. 1. If you have recently updated the firmware for one or more devices in the chassis (I/O module or CMM), install the previous level of firmware. 2.
Page 690
6. Install the compute node in another node bay, if one is available. If the problem remains, make sure that the compute node is connected to a port that has been enabled and that the vLAN settings allow that port to connect to the network.
Page 691
c. Perform a virtual reseat of the I/O module. d. Replace the I/O module. 7. Check the IBM Support Portal for any service bulletins that are related to network connectivity. 8. Remove the management node and make sure that the connectors on the midplane and the node are not damaged.
Page 692
b. Check the connectors on the nodes and the midplane to make sure that no pins are bent. c. Replace the I/O expansion card in the management node. Multiple nodes cannot ping the management node in the same chassis and different chassis: Use the information in this section to troubleshoot multiple nodes that cannot ping the IBM Flex System Manager management node in the same chassis or a different...
Page 693
1. Make sure that the management node is powered on and is not hung, by logging in to the management node. If you are unable to log in from the management network, attempt to log in from the data network. If the management node is powered on and hung, perform a virtual reseat of the management node from the CMM.
Page 694
4. Make sure that all cables between the CMMs and the top-of-rack switch are correctly connected and secure and that the activity LEDs are lit on the applicable ports. 5. Make sure that the Chassis Management Module (CMM)s (the Chassis Management Module (CMM) in the same chassis as the management node and the Chassis Management Module (CMM) in the remote chassis) have the same subnet address and can ping one another.
Page 695
management node is powered on and hung, perform a virtual reseat of the management node from the Chassis Management Module (CMM). 2. Make sure that the Chassis Management Module (CMM) is powered on and is not hung, by pinging the Chassis Management Module (CMM) from the management node: a.
Page 696
Multiple nodes cannot ping the management node in the same chassis and different chassis: Use the information in this section to troubleshoot multiple nodes that cannot ping the IBM Flex System Manager management node in the same chassis or a different chassis on the management network.
Page 697
12. (Trained service technician only) Check the connectors on the node and the midplane to make sure that no pins are bent. Related Links: “Installing a compute node in a chassis” on page 702 “Removing a compute node from a chassis” on page 701 http://www.ibm.com/support Single node cannot ping the management node in the same chassis: Use the information in this section to troubleshoot a single compute node that...
c. Replace the system-board assembly (see Removing the system-board assembly and Installing the system-board assembly). Related Links: “Installing the system-board components for base-assembly replacement” on page 769 “Removing the system-board components for base-assembly replacement” on page 767 http://www.ibm.com/support Hard disk drive problems Use this information to resolve hard disk drive problems.
4. Contact IBM Support. Related Links: “Installing a hot-swap hard disk drive” on page 740 “Installing an SMP expansion connector” on page 747 “Installing the hard disk drive cage and backplane assembly” on page 738 “Removing a hot-swap hard disk drive” on page 739 “Removing an SMP expansion connector”...
a. Make sure that the device is configured correctly (see Using the Setup utility). b. Connect the device to another port. If using a USB hub, remove the hub and connect the device directly to the compute node. Make sure that the device is configured correctly for the port (see Using the Setup utility).
3. If new memory has recently been installed, make sure that no configuration events are reported in the event log. If there are any events, resolve them. 4. If the compute node was recently installed, moved, or serviced, make sure that the DIMMs are correctly seated in the connectors (see Installing a DIMM).
5. Contact your place of purchase of the software or your software provider. Machine seems to be running hot On a single node: Check the IBM Flex System Manager management software (if installed) or CMM log for rising temperature events. If there are no events, the compute node is running within normal operating temperatures.
OS will not load via USB 3.0 port The USB 3.0 port on the front of the box can not be used to install some OSs, in particular, the Windows OSs, as the driver is not native to this OS and will require a device driver to work.
1. Isolate which network is operating slowly (such as storage, data, and management). You might find it helpful to use ping tools or operating-system tools such as task manager or resource manager. 2. Check for traffic congestion on the network. 3.
2. Check the event logs for any events that are related to the compute nodes, and solve them. If an IBM Flex System Manager management node is installed, check the event log on the management node. Otherwise, check the event log on the Chassis Management Module.
2. The compute node has the minimum memory that is needed to use the software. For memory requirements, see the information that comes with the software. a. The software is designed to operate on the compute node. b. Other software works on the compute node. c.
Raid degraded after de-scaling a multi-node system.: 1. Insure proper procedure for de-scaling was followed 2. Verify all cables and storage trays, backplane and raid card are fully seated. 3. Verify that RAID has been set up properly for the new configuration 4.
3. Make sure that the IBM Flex System Manager management node or the CMM can ping the compute nodes, if they cannot, see Cannot ping the IBM Flex System Manager management node on the management network. 4. If the compute nodes are in another chassis, make sure that you have the proper software entitlements to manage that chassis with the IBM Flex System Manager management node.
4. Remove or disconnect the following devices, one at a time, until you find the failure. Reinstall, turn on, and reconfigure the compute node each time. v I/O expansion adapter. v Hard disk drives. v DIMMs. The minimum configuration requirement is 4 GB (one 4 GB DIMM on the system board).
Page 710
Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259: Installation and Service Guide...
System reliability guidelines Use these guidelines to ensure that the compute node meets the cooling and system reliability requirements: v To ensure proper cooling, the Flex System chassis is not operated without a compute node or node bay filler in each node bay. See "Flex System Enterprise Chassis Types 8721, 8724, and 8725: Installation and Service Guide"...
When the compute node starts for the first time after you add or remove an internal device, you might receive a message that the configuration has changed. The Setup utility automatically starts so that you can save the new configuration settings.
Attention: v To maintain proper system cooling, do not operate the Flex System chassis without a compute node or node bay filler installed in each node bay. v When you remove the compute node, note the node bay number. Reinstalling a compute node into a different node bay from the one it was removed from can have unintended consequences.
Page 715
Procedure To install the compute node in a chassis, complete the following steps. Handle Handle 1. Select the node bay. Notes: a. If you are reinstalling a compute node that you removed, you must install it in the same node bay from which you removed it. Some compute node configuration information and update options are established according to node bay number.
Use this information for removing and replacing Tier 1 CRUs. About this task Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request, you will be charged for the installation. Removing the adapter-retention assembly Use this information to remove the adapter-retention assembly.
Procedure To remove the adapter-retention assembly, complete the following steps. Adapter retention assemblies Screws 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Remove the air baffles. 3. If necessary, remove the I/O expansion adapters (see “Removing an I/O expansion adapter”...
Page 718
Before you begin Before you install the adapter-retention assembly, complete the following steps: 1. Read “Safety” on page v and “Installation guidelines” on page 699. 2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis”...
7. Install the I/O expansion adapters, if you removed them (see “Installing an I/O expansion adapter” on page 742). 8. Install the air baffles. Attention: Install the air baffles with the arrow indicating airflow direction pointing to the rear of the compute node. What to do next After you install the adapter-retention assembly, complete the following steps: 1.
Before you begin Before you install the bezel, read “Safety” on page v and “Installation guidelines” on page 699. Procedure To install the bezel, complete the following steps. Left bezel Right bezel 1. Position the bezel on the front of the compute node. Make sure that the clips on the back of the bezel are inserted into the pins on the front of the drive tray.
Procedure To remove the center partition, complete the following steps. System board Release Center partition 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Remove the air baffles. 3. Press the center partition on the side to release it from the compute node. 4.
Procedure To install the center partition, complete the following steps. System board Center partition 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Remove the air baffles. 3. Place the center partition into position at the rear of the compute node. 4.
Procedure To remove the chassis bulkhead, complete the following steps. Screw Chassis bulkhead Screw Screws 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Remove the air baffles. 3. Remove the center partition (see “Removing the center partition” on page 708). 4.
Procedure To install the chassis bulkhead, complete the following steps. Screw Chassis bulkhead Screw Screws 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Remove the air baffles. 3. Remove the center partition (see “Removing the center partition” on page 708).
Before you begin Before you remove the CMOS battery, complete the following steps: 1. Read “Safety” on page v and “Installation guidelines” on page 699. 2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis”...
Page 726
v To order replacement batteries, call 1-800-426-7378 within the United States, and 1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and Canada, call your marketing representative or authorized reseller. v After you replace the CMOS battery, you must reconfigure the compute node and reset the system date and time.
What to do next After you install the CMOS battery, complete the following steps: 1. Install the cover onto the compute node (see “Installing the compute node cover” on page 716 for instructions). 2. Install the compute node into the chassis (see “Installing a compute node in a chassis”...
Push point Release button Posts Slots 3. Lay the cover flat or store it for future use. What to do next If you are instructed to return the cover, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing the compute node cover Use this information to install the compute node cover.
1. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. 2. Orient the cover so that the posts on the inside of the cover slide into the slots on the compute node. Note: Before you close the cover, make sure that the air baffles and all components are installed and seated correctly and that you have not left loose tools or parts inside the compute node.
Page 730
About this task After you install or remove a DIMM, you must change and save the new configuration information by using the Setup utility. When you turn on the compute node, a message indicates that the memory configuration has changed. Start the Setup utility and select Save Settings (see “Using the Setup utility”...
Attention: v Install the air baffles with the arrow indicating air flow direction pointing to the rear of the compute node. v To maintain proper system cooling, do not operate the compute node without air baffles installed over the DIMM connectors. What to do next If you are instructed to return the DIMM, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.
Page 732
The compute node has a total of 48 dual inline memory module (DIMM) connectors. The compute node supports low-profile (LP) DDR3 DIMMs with error-correcting code (ECC) in 4 GB, 8 GB, 16 GB, 32 GB, and 64 GB capacities. The following illustration shows the system-board components, including the DIMM connectors.
Page 734
Table 9. Memory-channel configuration (continued) Scalable DIMM Microprocessor SMI2 channel memory buffer DDR channel connector Microprocessor 2 SMI0 JC10 DDR0 DDR1 SMI1 JC11 DDR0 DDR1 SMI2 JC12 DDR0 DDR1 SMI3 JC13 DDR0 DDR1 The following notes describe information that you must consider when you install memory: v Only 8 GB and 16 GB RDIMMs are supported if you also install flash DIMMs.
Page 735
v Independent-channel mode: Independent-channel mode provides high performance memory capability. The memory channels can be populated with DIMMs in any order in independent mode. You can populate all four channels on each microprocessor in any order with no matching requirements. Individual channels can run at different DIMM timings, but all channels must run at the same interface frequency.
Page 737
Table 10. DIMM population sequence for independent-channel mode (continued) DIMM order DIMM connector DIMM 22 DIMM 34 DIMM 39 Install DIMMs in the order that is indicated in the following table for lockstep mode. Table 11. DIMM population sequence for lockstep mode Number of DIMM pairs installed DIMM connectors DIMMs 25 and 28...
Page 738
Table 12. DIMM population sequence for independent-channel mode with mirrored-channel memory (continued) Number of DIMM pairs installed DIMM connectors DIMMs 10 and 33 DIMMs 15 and 40 DIMMs 1 and 25 DIMMs 24 and 48 DIMMs 7 and 36 DIMMs 18 and 37 DIMMs 5 and 29 10th DIMMs 20 and 40...
Page 739
Procedure To install a DIMM, complete the following steps: 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Read the documentation that comes with the DIMM. 3. Remove the air baffle installed over the DIMM connector. 4.
Removing a fabric connector Use this information to remove a fabric connector. Before you begin Note: This procedure should be performed only by trained service technicians. Before you remove the fabric connector, complete the following steps: 1. Read “Safety” on page v and “Installation guidelines” on page 699. 2.
If you have removed the fabric connector to install an I/O expansion adapter in I/O expansion connector 1, keep the fabric connector in a safe place for future use. Installing a fabric connector Use this information to install a fabric connector. Before you begin Note: This procedure should be performed only by trained service technicians.
Removing a flash DIMM Use this information to remove a flash DIMM. Before you begin Before you remove a flash DIMM, complete the following steps: 1. Read “Safety” on page v and “Installation guidelines” on page 699. 2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis”...
Page 743
Before you begin Before you install a flash DIMM, complete the following steps: 1. Read “Safety” on page v and “Installation guidelines” on page 699. 2. Read the documentation that comes with the flash DIMMs. 3. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis”...
Page 744
v In two-node and four-node complexes, you can install 1, 2, 4, 8, 12, 16, or 32 flash DIMMs. v You can install flash DIMMs in only the two nodes in the lowest bay IDs in a four-node complex. v Flash DIMMs are not supported if lockstep mode, mirrored-channel mode, or rank sparing is enabled.
Page 745
Table 14. Flash DIMM population sequence in a one-node configuration with a maximum of 16 RDIMMs (continued) DIMM order DIMM connector DIMM type DIMM 27 Flash DIMM DIMM 46 Flash DIMM Table 15. Flash DIMM population sequence in a multi-node configuration with a maximum of 32 RDIMMs DIMM order DIMM connector...
Page 746
Table 15. Flash DIMM population sequence in a multi-node configuration with a maximum of 32 RDIMMs (continued) DIMM order DIMM connector DIMM type DIMM 43 Flash DIMM DIMM 12 Flash DIMM DIMM 13 Flash DIMM DIMM 6 Flash DIMM DIMM 19 Flash DIMM DIMM 31 RDIMM...
Attention: To avoid breaking the retaining clips or damaging the DIMM connector, handle the clips gently. 8. Press the flash DIMM into the DIMM connector. The retaining clips lock the flash DIMM into the connector. 9. Make sure that the small tabs on the retaining clips engage the notches on the flash DIMM.
Procedure To remove the front handles, complete the following steps. Front handles 1. Locate the screws that attache the handles to the compute node. 2. Using a T8 Torx screwdriver, remove the screw from each front handle and save the screw in a safe place. Use the same screws when you install the front handles.
Procedure To install the front handles, complete the following steps. Front handles 1. Orient the front handles so that the blue release latches are toward the middle of the compute node. 2. Align the hole in the handles with the holes on the compute node where the handles are installed.
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. Procedure To remove the hard disk drive cage and backplane assembly, complete the following steps. Hard disk drive cage and backplane assembly 1.
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. Procedure To install the hard disk drive cage and backplane assembly, complete the following steps. Hard disk drive cage and backplane assembly 1.
Before you begin Before you remove a hot-swap hard disk drive, complete the following steps: 1. Back up all important data before you make changes to hard disk drives. 2. Read “Safety” on page v and “Installation guidelines” on page 699. Procedure To remove a hot-swap hard disk drive, complete the following steps.
To install a hot-swap hard disk drive or hard disk drive bay filler, complete the following steps. Activity Error (green) (amber) Release latch Drive tray assembly Drive handle (in open position) Hard disk drive bay filler Procedure 1. Identify the hard disk drive bay (hard disk drive bay 0 or hard disk drive bay 1) in which you plan to install the hot-swap hard disk drive.
3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you. Procedure To remove an I/O expansion adapter, complete the following steps. Adapter 1. Remove the cover (see “Removing the compute node cover” on page 715). 2.
2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 701 for instructions). 3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you.
Procedure To install a light path diagnostics panel, complete the following steps. 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Connect the cable on the system board. 3. Align the light path diagnostics panel with the bracket. 4.
Page 758
v Flex System x480 X6 4-Socket Scalability Connector Important: The compute nodes must have Intel Xeon E7-4800 microprocessors or E7-8800 microprocessors to form a two-node (four-socket) complex. v Flex System x880 X6 8-Socket Scalability Connector Important: The compute nodes must have Intel Xeon E7-8800 microprocessors to form a four-node (eight-socket) complex.
Procedure To remove an SMP expansion connector, complete the following steps: 1. Press the blue release button to release the handle and disengage the SMP expansion connector from the compute node. 2. Grip the handle and pull the SMP expansion connector from the compute node. Note: Make sure that the handle is in the open position before disconnecting the connector from the compute node.
Page 760
v When you press the power-control button on any compute node in a single partition (controlled by one operating system), all compute nodes in the single partition will be turned on or turned off. About this task The information in this topic applies to the optional SMP expansion connectors available for the compute node: v Flex System x480 X6 4-Socket Scalability Connector Important: The compute nodes must have Intel Xeon E7-4800 microprocessors...
Page 761
Procedure To install an SMP expansion connector, complete the following steps. filler 1. Remove the SMP filler from the compute node, if one is present. 2. Remove the protective covers from the connectors on the SMP expansion connector. Connector covers Flex System X6 4 - socket scalability connector...
5. Press the handle against the assembly to lock the assembly against the compute node. What to do next See “Working with scalable partitions” on page 22 for information about configuring, modifying, and deleting scalable partitions. Removing a solid state drive Use this information to remove an 1.8-inch hot-swap solid state drive (SSD).
Note: When you remove a drive from the compute node, consider labeling the drive to indicate the slot from which the drive was removed so that you can install the drive back into the same slot. 4. Close the retention lever and secure it with the latch. Note: You might have to press the latch before you close the retention lever.
3. If you have a second solid state drive to install, repeat steps 1 on page 751 through 2 on page 751. 4. Close the retention lever and secure it with the latch. Note: You might have to press the latch before you close the retention lever. What to do next See “Configuring a RAID array”...
About this task The solid state drive cage and backplane are available in the optional Flex System flash kit. Procedure To remove the solid state drive cage and backplane, complete the following steps. Solid state drive backplane Solid state drive cage 1.
Page 766
2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 701 for instructions). 3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you.
2. Install the compute node into the chassis (see “Installing a compute node in a chassis” on page 702 for instructions). Removing the solid state drive mounting sleeve Use this information to remove the solid state drive (SSD) mounting sleeve. Before you begin Before you remove the SSD mounting sleeve, read “Safety”...
About this task The SSD mounting sleeve is available in the optional Flex System flash kit. Procedure To install the solid state drive (SSD) mounting sleeve, complete the following steps. SSD mounting sleeve 1. If necessary, remove the SSD bezel. 2.
Procedure To remove the USB flash drive, complete the following steps. 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Locate the USB connectors on the system board. Note: You might have to remove an I/O expansion adapter to remove the USB flash drive.
Procedure To install the USB flash drive, complete the following steps. 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Locate the USB connectors on the system board. Note: You might have to remove an I/O expansion adapter to remove the USB flash drive.
Page 771
1. Read “Safety” on page v and “Installation guidelines” on page 699. 2. If the compute node is installed in an Flex System chassis, remove it (see “Removing a compute node from a chassis” on page 701 for instructions). 3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you.
Page 772
b. Use a screwdriver to loosen the screws on the heat sink, rotating each screw two full turns until each screw is loose. Heat sink Standoff c. Gently pull the heat sink from the microprocessor and pivot the heat sink from the standoff.
Page 773
Handle Installation tool b. Align the installation tool with the screws on the microprocessor socket, and lower the tool on the microprocessor. The installation tool rests flush on the socket only if it is aligned correctly. Installation tool Microprocessor Screws c.
Installing a microprocessor and heat sink Use this information to install a microprocessor and heat sink. Before you begin Note: This procedure should be performed only by trained service technicians. Before you install a microprocessor and heat sink, complete the following steps: 1.
Page 775
Procedure To install a microprocessor and heat sink, complete the following steps: 1. Remove the cover (see “Removing the compute node cover” on page 715). 2. Remove the solid state drives (see “Removing a solid state drive” on page 750). 3.
Page 776
Note: Do not touch the microprocessor contacts. Contaminants on the microprocessor contacts, such as oil from your skin, can cause connection failures between the contacts and the socket. b. Remove the microprocessor protective cover if one is present. c. Align the installation tool with the microprocessor socket. The installation tool rests flush on the socket only if it is properly aligned.
Page 777
Dust cover Microprocessor bracket frame Release lever 1 Release lever 2 a. Remove the microprocessor dust cover. b. Close the microprocessor retainer on the microprocessor socket. c. Identify which release lever is labeled as the first release lever to close, and close it.
the screws on one side first, rather than alternating sides. Each screw should then be tightened two more full rotations. Do not overtighten the screws with excessive force. 12. Install the solid state drive mounting sleeve and solid state drive cage and backplane (“Installing the solid state drive mounting sleeve”...
0.02 mL of thermal grease Microprocessor 5. Use the thermal-grease syringe to place nine uniformly spaced dots of 0.02 mL each on the top of the microprocessor. Note: 0.01mL is one tick mark on the syringe. If the grease is properly applied, approximately half (0.22 mL) of the grease will remain in the syringe.
Page 780
you have the latest firmware or a copy of the preexisting firmware before you proceed. See “Updating firmware and device drivers” on page 25 for more information. See “System-board layouts” on page 17 for more information about the locations of the connectors, jumpers, and LEDs on the system board.
What to do next If you are instructed to return the base assembly, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing the system-board components for base-assembly replacement Use this information to install the system-board components as part of the procedure to replace the base assembly.
Page 782
1. Install all of the components in the following list that you removed from the old system board onto the new system board. v Center partition (see “Installing the center partition” on page 709). v Fabric connectors (see “Installing a fabric connector” on page 729). v Flash DIMMs, (see “Installing a flash DIMM”...
Page 783
3. The new system-board assembly comes with an IBM Repair Identification (RID) tag. Using a ball point pen, transfer the machine type and serial number from the old system-board assembly to the two labels on the IBM Repair Identification tag; then, place Tag 1 on the label tab (see “Installing a compute node in a chassis”...
Page 784
Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259: Installation and Service Guide...
Lenovo to assist you. Use this information to obtain additional information about Lenovo and Lenovo products, and determine what to do if you experience a problem with your Lenovo system or optional device. Note: This section includes references to IBM web sites and information about obtaining service.
The troubleshooting information or the diagnostic programs might tell you that you need additional or updated device drivers or other software. Lenovo maintains pages on the World Wide Web where you can get the latest technical information and download device drivers and updates.
In the U.S. and Canada, call 1-800-IBM-SERV (1-800-426-7378). Hardware service and support IBM is Lenovo's preferred service provider for the System x, Flex System and NeXtScale System products. You can receive hardware service through your Lenovo reseller or from IBM. To locate a reseller authorized by Lenovo to provide warranty service, go to http://www.ibm.com/partnerworld and click Business Partner Locator.
Page 788
IBM Taiwan Corporation 3F, No 7, Song Ren Rd. Taipei, Taiwan Telephone: 0800-016-888 Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259: Installation and Service Guide...
(TBW). A device that has exceeded this limit might fail to respond to system-generated commands or might be incapable of being written to. Lenovo is not responsible for replacement of a device that has exceeded its maximum guaranteed number of program/erase cycles, as documented in the Official Published Specifications for the device.
Lenovo makes no representations or warranties with respect to non-Lenovo products. Support (if any) for the non-Lenovo products is provided by the third party, not Lenovo. Some software might differ from its retail version (if available) and might not include user manuals or all program functionality.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Lenovo is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der Lenovo empfohlene Kabel angeschlossen werden. Lenovo übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung...
Dieses Gerät ist berechtigt, in Übereinstimmung mit dem Deutschen EMVG das EG-Konformitätszeichen - CE - zu führen. Verantwortlich für die Konformitätserklärung nach Paragraf 5 des EMVG ist die Lenovo (Deutschland) GmbH, Gropiusplatz 10, D-70563 Stuttgart. Informationen in Hinsicht EMVG Paragraf 4 Abs. (1) 4: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A.
Korea Communications Commission (KCC) statement This is electromagnetic wave compatibility equipment for business (Type A). Sellers and users need to pay attention to it. This is for any areas other than home. Russia Electromagnetic Interference (EMI) Class A statement People's Republic of China Class A electronic emission statement Taiwan Class A compliance statement Notices...
Page 796
Flex System x280 X6, x480 X6, and x880 X6 Compute Node Types 7903 and 4259: Installation and Service Guide...
Page 798
Ethernet device error codes (continued) hard disk drive cage and backplane IMM2 self test error codes (continued) 405-003-xxx 669 assembly 166-911-xxx 669 405-903-xxx 669 installing 738 166-912-xxx 669 405-904-xxx 669 removing 737 IMM2, partitioning a multi-node European Union EMC Directive hard disk drives complex 25 conformance statement 781...
Page 799
legacy Thunk support, Setup utility 29 SAS hard disk drive (continued) light path diagnostics 65 installing 740 particulate contamination 779 light path diagnostics panel 19 SAS ID address 49 partitioning a multi-node complex 25 installing 744 SATA hard disk drive parts listing 59 removing 743 hot-swap hard disk device 740...
Page 800
static-sensitive devices, handling 700 updating stopping the compute node 16 configuration 701 support web page, custom 775 device drivers 25 switches, system board 19 firmware 25 system board USB flash drive connectors 17 installing 757 jumpers 18 removing 756 layouts 17 user security, Setup utility 29 LEDs 19 switches 19...
Page 802
Part Number: 00WA623 Printed in USA (1P) P/N: 00WA623...