The F200E Charged-Media Air Cleaner captures a significant
amount of the air-borne particles from the air circulated through
the unit.

SPECIFICATIONS

IMPORTANT
The specifications in this publication do not include
normal manufacturing tolerances; therefore, an
individual unit may not exactly match the listed
specifications. This product is tested and calibrated
under closely controlled conditions, and some minor
differences in performance can be expected if those
conditions are changed.
Model:
F200E Charged-Media Air Cleaner includes a cabinet,
access door and pleated media filter, and an RF AirWatch™
Indicator.
® U.S. Registered Trademark
Copyright © 2000 Honeywell • All Rights Reserved
Charged-Media
FEATURES
• Charged-Media filter captures particles as small as 0.3
micron.
• Efficiency and arrestance ratings based on the
American Society of Heating, Refrigerating and Air
Conditioning Engineers Standard 52.2-1999.
• Applicable to all gas, oil, and electric forced warm air
furnaces and to compressor cooling up to 5 tons.
• Mounts in the return air duct.
• Cabinet can support weight of residential furnace and
evaporator coil.
• Requires no electrical connections.
• Mounts in any position.
• Requires no maintenance except periodic media filter
replacement.
• Quick and easy media filter replacement.
• Later upgrade to electronic air cleaner is easy.
• Integral pressure sensors signal when filter change is
required based on increased pressure drop threshold
at filter.
• Filter change status is transmitted to wall-mounted
AIRWATCH™ Indicator.
• The RF AIRWATCH™ Indicator is included.
Application:
Use with gas, oil, and electric forced warm air furnaces and
with compressor cooling. Can be used with heat pumps if
filter is changed regularly to prevent excessive pressure drop.
Efficiency:
Efficiency Ratings: Based on American Society of Heating,
Refrigerating and Air-Conditioning Engineers Standard
52.2-1999.
Initial Efficiency: 43 percent (0.3 micron particles);
76 percent (1.0 micron particles)
Minimum Efficiency Reporting Valve (MERV): 10 at 492 fpm.
Initial Dust Spot Efficiency: 61% (ASHRAE 52.1).
F200E

Air Cleaner

PRODUCT DATA
68-0238

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell F200E

  • Page 1: Air Cleaner

    APPLICATION at filter. • Filter change status is transmitted to wall-mounted AIRWATCH™ Indicator. The F200E Charged-Media Air Cleaner captures a significant amount of the air-borne particles from the air circulated through • The RF AIRWATCH™ Indicator is included. the unit.
  • Page 2: Ordering Information

    Capacity And Pressure Drop: See Fig. 2. Upgrade Path: Initial Pressure Drop: 0.177 in. wc at 492 fpm. The F200E uses the same cabinet as the F300 Electronic Air Cleaner. Upgrade may require installing the cell key, ° °...
  • Page 3: Applications With Air Conditioning

    This condition in a cooling system. The filter will help to keep the coil clean causes the indicator light on the F200E door t begin flashing and reduce maintenance. and the transmitter to send a signal to the wall-mounted RF Indicator that the filter needs replacing.
  • Page 4 F200E CHARGED-MEDIA AIR CLEANER M14789 M941A Fig. 5. Highboy furnace, with closet installation. Media air Fig. 7. Counterflow furnace, with media air cleaner cleaner is mounted vertically on furnace between furnace mounted horizontally in return duct or plenum just and louvered return air opening in closet door.
  • Page 5: Determining Sheetmetal Requirements

    F200E CHARGED-MEDIA AIR CLEANER Offsets If the duct connection to the furnace in a side installation allows less than 7 in. (178 mm) for mounting media air cleaner cabinet, attach an offset to the elbow. See Fig. 13. DUCT SIZE CHANGED GRADUALLY TO PREVENT TURBULENCE.
  • Page 6: Installation And Checkout

    Fasten The Cabinet To The Furnace Push and hold the AIRWATCH Indicator button until all four arrows come on (about five seconds). Push the reset button on the F200E door within two Align the cabinet with the return air opening. Place blocks minutes.
  • Page 7 • Joints in sheetmetal between media fir filter and fur-nace hold the device to the wall. are sealed. b. At the F200E, press the reset button on the door. • All sheetmetal connections are complete. c. Verify that the arrows on the AIRWATCH Indicator are •...
  • Page 8 On/Battery indicator on continuously. AIRWATCH™ is functioning normally. On/Battery indicator flashing. Flashing two seconds on, six seconds off: Replace battery in the F200E door. Do not press any reset buttons after battery change. Flashing two seconds on, two seconds off: Replace battery in AIRWATCH. Do not press any reset buttons after battery change.

Table of Contents