1-13. Envelope Waveform Adjustment
V1/Vmax, V2/Vmax, V3/Vmax ≥ 0.8
SPEC
TEST POINT
TP500 R/P ENV (RF Board)
TP300 R/P HSW (RF Board)
ADJUSTMENT S1, T1 Post Height
MODE
PLAY (ATF)
TAPE
VFM3580KM, VFM3680KM
M.EQ
Oscilloscope
TOOL
VFK1149 (Post Driver)
1. Playback the the alignment tape.
2. Adjust S1 and T1 post height so that the R/P
envelope output is within the specification.
3. When the S1 and T1 posts are adjusted, first
raise the post height and make small the
entrance and exit side of the envelope, then
down the post until envelope becomes flat.
4. With order to adjustment, basically adjust T1
post for makes flat at exit side of envelope first
and adjust S1 post.
5. After finish this adjustment, unload the tape
and load the tape again, then confirm the
shape of Envelope waveform does not
changed.