  • Page 1 Digital Infrared Wireless Classroom Audio System  Installation and Operating Manual V 1.9...
  • Page 2 To protect your hearing, please avoid high pressure level on earphones. Adjust to a lower and convenient level. If any detailed information needed, please contact your local retailer or TAIDEN service center in your region.  Any feedback, advice and suggestion about the products is appreciated.
  • Page 3: Important Safety Instructions

    TAIDEN Service Center. splashing and that no objects filled with liquids, such as 20. All TAIDEN products are guaranteed for definite time vases, shall be placed on the apparatus. (see the WARRANTY CARD for details) excluding the...
  • Page 4 Important Safety Instructions WARNING: To reduce the risk of electric shock, DO NOT expose units to rain or moisture. Attention: Installation should be performed by qualified service personnel only in accordance with the National Electrical or applicable local codes. Power Disconnect: Units with or without ON – OFF switch have power supplied to the unit whenever the power cord is inserted into the power source;...
  • Page 5 Lithium battery safety precautions  To change battery please power off and take off the battery immediately.  Keep the battery away from heat sources to prevent fire or explosion.  Do not use a battery that is leaking, deformed, discolored or overheats. ...
  • Page 6: Table Of Contents

    Contents Installation & User Guide ......................VIII Chapter 1 System introduction ....................1 1.1 Overview ..................................1 1.2 Functions and features ..............................3 1.3 System technology ..............................4 1.3.1 Basic system concept ..............................4 1.3.2 IR radiation .................................. 4 1.3.3 Carriers and channels ..............................4 1.4 Factors impacting infrared signal transmission ......................
  • Page 7 3.4.1 Ceiling mounted ................................ 23 3.4.2 Tripod mounted ................................. 25 3.4.3 Wall mounted (Adjustable angle) ..........................26 3.5 Connecting to main unit ............................. 27 Chapter 4 Economical Digital infrared Wireless System Combo Unit ........28 4.1 Overview ..................................28 4.2 Functions and indications ............................28 4.3 Installation ..................................
  • Page 8 8.6 Power adapter ................................58 8.7 Charging unit ................................58 8.8 Connection details ..............................59 Appendix ..........................60 AppendixⅠ: Connect RG-59 Coaxial-cable to TES-5600R ..................... 60 AppendixⅡ: Soldering of BNC connector and RG-59 Coaxial-cable ................60...
  • Page 9: Installation & User Guide

    The manual is divided into the following chapters: Chapter 1: Introduction Chapter 7: Fault diagnosis Introduction to the TES-5600 system, as well as to the Trouble-shooting guide for simple faults. structure, technical principle, and aspects of system planning. Chapter 8: Technical data...
  • Page 10 Installation & User Guide This manual is applicable to: TES-5603B  Digital IR Wireless System Main Unit Digital Wireless Microphone (pendant type, TES-5600MA/02P rechargeable battery) Digital Infrared Wireless System Main Unit (supports 2 wireless microphones, built-in amplifier, supports 4  Power Adapter speakers, with phantom power) TES-ADP5V...
  • Page 11: Chapter 1 System Introduction

    Chapter 1 System introduction 1.1 Overview TAIDEN TES-5600 series product is a digital infrared easy-manageability and audio clarity, etc. wireless classroom audio system. This system The system consists of one digital infrared wireless provides ideal audio solution teaching main unit, one or more digital infrared receivers,...
  • Page 12  TES-5600MB/02P Tripod Digital Infrared Wireless System Main Unit (supports 2 TES-5600ZJ1 Microphone Stand wireless microphones, with phantom power) TES-5600ZJ2 Microphone/Receiver Stand TES-5600MBU/02P TES-5600RZJ Fixing Bracket Digital Infrared Wireless System Main Unit (supports 2 wireless microphones, USB interface for digital audio ...
  • Page 13: Functions And Features

    1.2 Functions and features World’s first Digital infrared wireless 6. No radiation TAIDEN classroom audio system operating  Not restricted by radio frequency licensing thus dirATC technology digital infrared Audio saving radio frequency resources Transmission and Control technology  Free from radiation since there is no radio power output 2.
  • Page 14: System Technology

    TES-5600 system Figure 1.2 The basic system concept 1.3.2 IR radiation Audio and control signals of TES-5600 are transmitted as modulated infrared light. Infrared radiation is part of the electro-magnetic spectrum, which is composed of visible light, radio waves and other types of radiation.
  • Page 15: Factors Impacting Infrared Signal Transmission

    Shadows from walls and furniture will influence the transmission of infrared light. This can be solved by TES-5600 system adopts 1-8 MHz wave band, and has using a sufficient quantity of receivers. They should be a good anti-interference performance (see figure 1.3).
  • Page 16: Chapter 2 Digital Ir Wireless System Main Unit

    Chapter 2 Digital IR Wireless System Main Unit 2.1 Overview TES-5600M series digital infrared wireless system main unit is the heart of the TES-5600 wireless classroom audio system. The main unit can be connected to digital infrared receivers and recording devices and: ...
  • Page 17: Functions And Indications

    2.2 Functions and indications Front panel of TES-5600M main unit Rear panel of TES-5600MA/P main unit Rear panel of TES-5600MAU/P main unit Rear panel of TES-5600MB/P main unit Rear panel of TES-5600MBU/P main unit Figure 2.1 Digital infrared wireless system main unit...
  • Page 18 Figure 2.1: 1. “POWER” button and indicator 2. Menu display  128×36 OLED, displays main unit status and configuration menu. 3. Knob  For menu operation;  For master volume control. 4. Receiver interfaces (1-4, BNC) 5. Device USB interface ...
  • Page 19: Installation

    2.3 Installation TES-5600M series digital infrared wireless system Note: main unit is half-rack width and can be fixed in a  There are vents in the both sides and bottom of standard 19-inch cabinet single or for two main units the main unit.
  • Page 20: Connection

    2.4 Connection Several typical system connections of TES-5600M 2.4.2 To recording device series main unit will be introduced in this section, Digital infrared wireless system main unit has LINE including connection: OUT interface which can be connected to recording  To other auxiliary devices devices.
  • Page 21: To Central Control System

    2.4.4 To central control system TES-5600M has the functions of microphone controlling controlling and controlling of various electric devices, and volume adjusting. Also, TAIDEN TES-5600 digital such as DVD, recorder, etc. RS-232C interface is infrared wireless classroom audio system and TAIDEN available.
  • Page 22: Configuration And Operation

    2.5 Configuration and operation Digital infrared wireless system main unit can be configured and set up through menu operation with knob. All menu items operation will be introduced one by one in this section. A) Starting initialization Switch on and press the "POWER" button, the TES-5600M digital infrared wireless system main unit will ...
  • Page 23: Line In Vol

    2.5.2 Line In Vol. 1. Press the knob to enter the setting interface; Adjust the volume of Line In, range: -∞ (mute), -30 dB to 0 dB. 2. Rotate the knob to select a fade way among Off, Low Voice, High Voice and IR Signal. ...
  • Page 24: Line In 1 Set

    2.5.6 Line In 1 Set. 2.5.9 About Display the version of the device. 1. Press the knob to enter the setting interface; In this interface, user also can see the information of the microphone in use, see and change the receivable frequencies of the main unit.
  • Page 25 D) Protection Note:  Overload protection: activated when the output of  Please receivable frequencies the amplifier is overloaded, and the OLED displays changing function restrainedly for keeping “PA OverLoad”; normal use;  BNC protection: activated when BNC short circuit ...
  • Page 26: Usb Link

    2.6 USB LINK TES-5600MU series main unit has a built-in USB Audio (2 channels, 16bit, 44.1kHz) which can be connected to the computer through USB cable (software requirement: Win7 or higher) for digital audio input/output. TES-5600M/P main unit cooperating with the TES-5603(B) can realize remote PPT-page switch control. In the following we take TES-5600MAU/P with Win7 system as an example to introduce the function and operation of the USB Audio.
  • Page 27: Digital Audio Input

    2.6.2 Digital audio input When the TES-5600MU main unit is connected to computer with USB cable, lossless sound can be recorded during class on computer. Using the recording software or the third party communication software, such as recorder, Skype and so on, functions like recording, remote instruction, remote communication can be implemented.
  • Page 28: Digital Audio Output

    2.6.3 Digital audio output The TES-5600MU main unit can be connected to the computer for digital audio output. Please adjust and test the TES-5600M USB LINK to a suitable volume when using for the first time. Adjust method: open the control panel-sound (or right click the volume icon on the taskbar and select sound), and select the speakers (TES-5600M USB LINK) and modify its setting in the Playback dialog box, as shown in the following figure: Figurer2.12: Adjusting playback volume...
  • Page 29: Ppt

    2.6.4 PPT-page switch The TES-5600M/P main unit cooperates with the TES-5603(B) microphone to realize remote PPT-page switch control. See 5.4.3.
  • Page 30: Chapter 3 Digital Infrared Receiver

    Chapter 3 Digital infrared receiver 3.1 Overview 3.2 Functions and indications The digital infrared receiver receives the infrared signals from the digital infrared wireless microphone, and sends the signals to the main unit. It can be mounted onto the ceiling. Reception angle: Vertical 150°(±75°);...
  • Page 31: Position Planning

    3.3.1.1 Position away from lighting equipment Although TES-5600 system has good anti-interference performance to ambient light, the distance of the receiver from lighting equipment must be at least 50 cm to guarantee adequate intensity and stability of infrared signals.
  • Page 32: Example For Planning The Receiver

    3.3.2 Example for planning the receiver The reception angle of the TES-5600R is 150°in vertical and 360°in horizontal. For a good reception, please plan the receiver according to the teaching environment. 【8m×8m classroom】 In an 8m×8m classroom, one TES-5600R receiver can be mounted on the ceiling in the front middle part of the classroom and about 2 to 3 meters (L) away from the blackboard (figure 3.5 ).
  • Page 33: Installation

    3.4 Installation 3.4.1 Ceiling mounted 3.4.1.1 Ceiling mounted 1 ① M3 screw ② Fixing bracket ③ Rubber plug ④ Hard ceiling (such as concrete ceiling) ⑤ TES-5600R(N) digital infrared receiver TES-5600R(N) Figure 3.7 digital infrared receiver ceiling mounted 1 Mounting steps: Step 1: Position the fixing bracket on the ceiling according to the installation location of the TES-5600R(N) and mark the positions of the drilling holes.
  • Page 34 3.4.1.2 Ceiling mounted 2 ① M3 screw ② Fixing bracket ③ Nut ④ Ceiling ⑤ TES-5600R(N) digital infrared receiver Figure 3.8 TES-5600R(N) digital infrared receiver ceiling mounted 2 Mounting steps: Step 1: Position the fixing bracket on the ceiling according to the installation location of the TES-5600R and mark the positions of the drilling holes.
  • Page 35: Tripod Mounted

    3.4.2 Tripod mounted ① Tripod-mounted stator ② M3 screw ③ Nut ④ Fixing bracket ⑤ TES-5600RZJ (with flexible tube) ⑥ TES-5600ZJ2 Figure 3.9 TES-5600R(N) digital infrared receiver tripod mounted Mounting steps: Step 1: Fix the fixing bracket onto the TES-5600RZJ with M3 screws; Step 2: Fix the tripod-mounted stator onto the other end of the TES-5600RZJ with M3 screws;...
  • Page 36: Wall Mounted (Adjustable Angle)

    3.4.3 Wall mounted (Adjustable angle) ① Tripod-mounted stator ② M3 screw ③ Nut ④ Fixing bracket ⑤ TES-5600RZJ (with flexible tube) ⑥ Wall TES-5600R(N) Figure 3.10 digital infrared receiver tripod mounted Mounting steps: Step 1: Fix the fixing bracket onto the TES-5600RZJ with M3 screws; Step 2: Put the slots of TES-5600R(N) digital infrared receiver into the fixing bracket and fix it with clockwise rotation;...
  • Page 37: Connecting To Main Unit

    3.5 Connecting to main unit Connect the receiver to the main unit with RG-59 coaxial-cable (see figure 3.11). Figure 3.11 Digital infrared transceiver connecting to digital infrared wireless system main unit Note:  The correctness of the cable connection can be ensured when the transceiver indicator is lit up.
  • Page 38: Chapter 4 Economical Digital Infrared Wireless System Combo Unit

    Chapter 4 Economical Digital infrared Wireless System Combo Unit 4.1 Overview 4.2 Functions and indications The economical digital infrared wireless system combo unit integrates the digital infrared wireless system main unit and the digital infrared receiver. It comes with built in amplifier supports (TES-5630MA)
  • Page 39: Installation

    4.3 Installation 4.3.1 Ceiling mounted 4.3.1.1 Ceiling mounted 1 ① TES-5630M ② ceiling-mounting kit ③ Mounting hole (drilled on the ceiling) ④ Ceiling Figure 4.3 TES-5630M ceiling mounted 1 Mounting steps: Mounting steps: Step 1: Install the ceiling mounting kit at the top of the TES-5630M; Step 2: Drill a hole with 98 mm diameter into the ceiling (for mounting and heat elimination during operation);...
  • Page 40 4.3.1.2 Ceiling mounted 2 ① M3 screw ② Hard ceiling mounting bracket ③ Rubber plug ④ Ceiling ⑤ TES-5630M Figure 4.4 TES-5630M ceiling mounted 2 Mounting steps: Step 1: Position the mounting bracket on the ceiling according to the installation location of the TES-5630M and mark the positions of the drilling holes.
  • Page 41: Tripod Mounted

    4.3.2 Tripod mounted 4.3.2.1 Ceiling mounted 1 ① Hard ceiling mounting bracket ② TES-5630M ③ TES-5600ZJ2 (should be ordered separately) Figure 4.5 TES-5630M tripod mounted 1 Mounting steps: Step 1: Put the bracket on the bottom of the TES-5630M and fix it with rotation; Step 2: Aim the mounting hole at the bottom of TES-5630M to the screw on the tripod;...
  • Page 42 4.3.2.2 Ceiling mounted 2 (Adjustable angle) ① TES-5630M ② M3 screw ③ TES-5600RZJ (with flexible tube) ④ Tripod-mounted stator ⑤ TES-5600ZJ2 (should be ordered separately) Figure 4.6 TES-5630M tripod mounted 2 Mounting steps: Step 1: Fix the TES-5630M onto the TES-5600RZJ with M3 screws; Step 2: Fix the tripod-mounted stator onto the other end of the TES-5600RZJ with M3 screws;...
  • Page 43: Wall Mounted (Adjustable Angle)

    4.3.3 Wall mounted (Adjustable angle) ① TES-5630M ② M3 screw ③ TES-5600RZJ (with flexible tube) ④ Wall Figure 4.7 TES-5630M Wall mounted Mounting steps: Step 1: Fix the TES-5630M onto the TES-5600RZJ with M3 screws; Step 2: Position the TES-5600RZJ on the wall according to the installation location of the TES-5630M and mark the positions of the drilling holes.
  • Page 44: Connection

    4.4 Connection Several typical system connections of TES-5630M 4.4.3 To other auxiliary devices economical digital infrared wireless system combo unit TES-5630M can be connected to an external audio will be introduced in this section, including connection: device through LINE IN interface. The external audio ...
  • Page 45: Operation

    4.5 Operation The operation of the TES-5630 economical digital infrared FB (feedback) suppress wireless system combo unit will be introduced in detail in Setting a FB suppress level through different this section. combinations of the two switches. Switch combination Trigger signal sources Adjust the master volume 01/10 Rotate the Vol.
  • Page 46: Chapter 5 Digital Infrared Wireless Microphone

    Chapter 5 Digital infrared wireless microphone 5.1 Overview TES-560X digital infrared wireless microphone is the basic devices for the user, divided into pendant type and handheld type. Different functions available, depending on the microphone type. Functions include: speak and mute, frequency selection, own sensitivity setting, remote volume control, etc.
  • Page 47: Functions And Indicators

    TES-5602A (front) TES-5602A (bottom) TES-5602A (back) TES-5603(B) (front) TES-5603(B) (back) TES-5603(B) (top) TES-5603(B) (bottom) Figure 5.1 TES-5600 series digital infrared wireless microphone Figure 5.1: 1. Microphone 3. Battery/charge indicator 2. Infrared transmitting glass 4. Mute button 5. Power ON/OFF button Note: 6.
  • Page 48 10. Charging port (USB) 11. Charging contacts 12. Selector button  Select which source (OWN, OTR or LINE) will be controlled by the remote volume buttons;  Press and hold on this button to open/close the PPT mode. 13. Function button (F) ...
  • Page 49: Infrared Service Area

    The infrared glass on The vertical transmission angle is 90°, the horizontal TES-5600 series digital infrared wireless microphone is transmission angle for TES-5603(B) is 120°and for designed to be at its best position to guarantee TES-5602A is 360°...
  • Page 50: Operation

    5.4 Operation The operation of the TES-5602A and TES-5603 digital infrared wireless microphones will be introduced in detail in this section. 5.4.1 TES-5602A (handheld type) TES-5602A handheld type digital infrared wireless 2. External audio input microphone combines speaking, mute, and working mode External audio devices (such as CD player) can be setting all in one.
  • Page 51: Tes-5603(B) (Pendant Type)

    5.4.2 TES-5603(B) (pendant type) 6. Charging The TES-5603(B) pendant type digital infrared wireless The TES-5602A is powered by a rechargeable Lithium microphone combines speaking, mute, working mode battery and it also can be charged via the USB port. setting and remote volume control all in one. Other When charging, it switches to external power supply peripheral devices like external microphone, MP3 player mode automatically.
  • Page 52 Voice control setting Note: Enable/disable voice control for TES-5603.The default is  Microphones with the same frequency channel OFF. cannot be used in one classroom at the same Steps: time. Press and hold simultaneously the function(F) and  The maximal number of active microphones is the power/mute buttons for more than 2 seconds, the according to the type of the main unit.
  • Page 53 Fitting the microphone PPT Mode OWN indicator Green  Neck strap: adjust the looped part’s length of the neck strap to find a suitable position for the speaker Press the “▲/▼”button to turn pages of the PPT and for a perfect sound quality; when PPT mode is on.
  • Page 54: Chapter 6 Accessories

    Chapter 6 Accessories 6.1 Power Adapter  TES-ADP15V power adapter  TES-ADP24V power adapter Connect the TES-ADP15V to the power adapter Connect the TES-ADP24V to the power adapter interface at the rear panel of the TES-5600MB digital interface at the rear panel of the TES-5600MA digital infrared wireless system unit.
  • Page 55: Dedicated Cable

    6.2 Dedicated Cable   Receiver cable Power adapter extension cable and connection CBL5600 dedicated receiver cable is used to connect terminal the digital infrared receiver and the main unit. It features Power adapter extension cable used one BNC connector. TES-ADP24VN power adapter.
  • Page 56: Speaker

    6.3 Speaker   HPA-2140 ceiling speaker HPA-2220 wall-mounted speaker Ceiling mounting; Wall-mounted; Cutout for mounting: 198 mm to 208 mm; Dimensions: 215×170×150 mm; Power consumption: 8 Ω, 20 W; Dimensions: Ø 230×128 mm; Power consumption: 8 Ω, 40 W; Frequency response: 85 Hz~20 kHz;...
  • Page 57   HPA-2240 wall-mounted speaker HPA-22100 wall-mounted speaker Wall-mounted, equipped with U bracket; Wall-mounted; Dimensions: 290×215×190 mm; Dimensions: 455×280×270 mm; Power consumption: 8 Ω, 40 W; Power consumption: 8 Ω, 100 W; Line voltage: 70~100 V (HPA-2240A) Frequency response: 40 Hz~20 kHz; Frequency response: 75 Hz~20 kHz;...
  • Page 58: Tes-5600Zj1

    6.4 TES-5600ZJ1 6.6 TES-5600CHG Charging Unit TES-5602A microphone stand: weight 0.5 kg, height The charging unit can recharge 2 TES-5600BAT 0.15 meter. rechargeable Lithium batteries at one time by using Micro USB. Two charging indicators display the battery status. The charging circuit will check if the battery is connected and control the charging process.
  • Page 59: Charging Station

    6.7 Charging station 6.8 Li-ion Rechargeable battery   TES-5600CS charging station TES-5600BAT Li-ion rechargeable battery TES-5600CS charge TES-5602A For TES-5602A/TES-5603B digital infrared wireless TES-5603(B) at the same time with TES-ADP5V. microphone. Voltage: 3.7 V DC Capacity: 1600 mAh Dimensions (mm): 55 x Ø 18 Weight: 38 g Figure 6.21 TES-5600CS charging station Figure 6.24 TES-5600BAT...
  • Page 60: Tes-5600Rzj

    6.9 TES-5600RZJ TES-5600RZJ is suitable for tripod or wall mounted of TES-5600R(N).  Length 115 mm  Weight 110 g Figure 6.26 TES-5600RZJ...
  • Page 61: Chapter 7 Fault Diagnosis

    Chapter 7 Fault diagnosis Some simple trouble-shooting instructions are provided in this chapter. If more serious faults arise, please contact a qualified technician. 7.1 Digital infrared wireless microphone Fault Analysis Solution The battery is not charged when leaving The battery is not charged. the factory, please fully charge the battery (When using the lithium-ion battery) Cannot start up.
  • Page 62: Usb Link

    7.3 USB LINK Fault Analysis Solution Pull out and then insert the USB cable Detect USB LINK failed again. TES-5600M USB LINK is not the Select TES-5600M USB LINK as current current audio device audio device manually. No audio input/output. TES-5600MU connects to a single HUB Manifold USB devices in one HUB channel.
  • Page 63: Chapter 8 Technical Data

    Chapter 8 Technical data 8.1 System specification System performance System environmental conditions Conforms to IEC 60914, the international standard for Working conditions fixed/stationary/transportable conference systems Temperature range: - Transport: -40 °C to +70 °C - Operating: 0 °C to +45 °C Transmission characteristics Max.
  • Page 64: Digital Infrared Wireless System Main Unit

    8.2 Digital infrared wireless system main unit Type TES-5600MA(U)/02P TES-5600MB(U)/02P √ Discussion Voltage DC 24 V (TES-ADP24 V adapter) DC 15 V (TES-ADP15 V adapter) Static consumption 24 V,360 mA 15 V,375 mA Line in +16 dBu Line out +18 dBu Maximal number of microphone Number of connectable receivers Max.
  • Page 65: Digital Infrared Receiver

    8.3 Digital infrared receiver Type TES-5600R TES-5600RN Voltage 12 V DC (supplied from TES-5600M) Max. 45 mA Current consumption Ceiling, tripod mounting Mounting Wavelength 870 nm Modulation method DQPSK Carrier frequency 1-8 MHz Horizontal: 360° Communication area Vertical: 150° Connection terminal CBL5600 dedicated cable Dimensions (mm) Weight...
  • Page 66: Economical Digital Infrared Wireless System Combo Unit

    8.4 Economical digital infrared wireless system combo unit Type TES-5630M(A) Voltage 24 V DC Max. 260 mA Current consumption 2 (TES-5630M); Maximal number of microphone 1 (TES-5630MA) 1×BNC Number of connectable receivers Max. 2×30 W (8 Ω) Speaker interface Virtual: 2×23 W (8 Ω) >...
  • Page 67: Digital Infrared Wireless Microphone

    8.5 Digital infrared wireless microphone Type TES-5602A TES-5603(B) √ √ Discussion √ Remote volume control Lithium battery or USB supply (5 V) Lithium battery or USB supply (5 V) Voltage or AA alkaline cell (only TES-5603) ≤360 mA ≤160 mA Current consumption Wavelength 870 nm (AM: Brightness modulation)
  • Page 68: Power Adapter

    8.6 Power adapter Type TES-ADP15V TES-ADP24V TES-ADP24VN TES-ADP5V6A TES-ADP5V Mains voltage AC 100-240 V, 50 /60 Hz Output 15 V DC, 2.4 A 24 V DC, 2.7 A 24 V DC, 1.5 A 5 V DC, 6.0 A 5 V DC, 2.0 A Cable Length 2.8 m 1.0 m...
  • Page 69: Connection Details

    8.8 Connection details  Audio cables Chinch connector (male) Pin ① Signal + Pin ② GND 6.4 mm Jack plug Tip① Balance/ Unbalance signal + Ring② Balance/ Unbalance signal - Sleeve③ Ground/ Shield NOTE: The LINE IN of TES-5600M/P must be balance signal.
  • Page 70: Appendix

    Appendix AppendixⅠ: Connect RG-59 Coaxial-cable AppendixⅡ: Soldering of BNC connector to TES-5600R and RG-59 Coaxial-cable 1. Strip 10mm insulation of cable sheaths, twist the 1. Strip 5mm insulation of cable sheaths, twist the braided shield into a bundle and cut off unnecessary braided shield into a bundle and cut off unnecessary Mylar paper and insulation;...
  • Page 71 TAIDEN INDUSTRIAL CO., LTD. 6/F, Block B, Future Plaza, 6060 Qiaoxiang Rd, Nanshan District, Shenzhen, China P.C.: 518053 Copyright by TAIDEN Website: http://www.taiden.com Last Revision: 08/2017...

Table of Contents