Lenovo Storage D1212 and D1224 Drive Enclosures
Product Guide
The Lenovo Storage D1212 and D1224 Disk Expansion Enclosures offer 12 Gbps SAS direct-
attached storage expansion capabilities that are designed to provide simplicity, speed, scalability, security,
and high availability for small to large businesses. The D1212 and D1224 deliver enterprise-class storage
technology in a cost-effective solution with flexible drive configurations and RAID or JBOD (non-RAID) host
connectivity.
The D1212 and D1224 expansion units are designed for a wide range of workloads, including big data and
analytics, video surveillance, media streaming, private clouds, file and print serving, e-mail and
collaboration, and databases. They also well-suited for software defined storage (SDS) and Windows
Server solutions with Storage Spaces.
Figure 1. Lenovo Storage D1212 and D1224 Disk Expansion Enclosures
Did you know?
The D1212 and D1224 expansion enclosures offer flexible drive configurations with the choice of 2.5-inch
and 3.5-inch drive form factors, 10K or 15K rpm SAS and 7.2K rpm NL SAS hard disk drives (HDDs) and
self-encrypting drives (SEDs), and SAS solid-state drives (SSDs).
With support for daisy chaining, the D1212 can be scaled up to 960 TB for capacity-optimized
configurations with HDDs, and the D1224 can be scaled up to 192 drives for performance-optimized
configurations.
The D1212 and D1224 expansion units support 12 Gbps SAS connectivity, which doubles the data
transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive
applications.
Click here to check for updates
Lenovo Storage D1212 and D1224 Drive Enclosures
1

Advertisement

Table of Contents
loading

Summary of Contents for Lenovo D1212

  • Page 1 RAID or JBOD (non-RAID) host connectivity. The D1212 and D1224 expansion units are designed for a wide range of workloads, including big data and analytics, video surveillance, media streaming, private clouds, file and print serving, e-mail and collaboration, and databases.
  • Page 2: Key Features

    Support multiple host attachments and SAS zoning for storage partitioning The D1212 and D1224 are designed to support the complete range of data storage requirements, from highly utilized applications to high-capacity, low usage applications.
  • Page 3: Components And Connectors

    The D1212 and D1224 expansion enclosures are designed to offer high levels of system and data availability with the following technologies: Dual ESMs provide redundant paths from a supported RAID controller to the drives in the enclosures for I/O load balancing and failover...
  • Page 4: System Specifications

    3x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (A, B, C) per ESM Drive bays D1212: 12 LFF hot-swap drive bays; up to 8x D1212 enclosures can be daisy chained on a supported RAID adapter or HBA for a total of up to 96 LFF drives.
  • Page 5 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm NL SAS HDDs 4 TB 7.2K rpm NL SAS SED HDD Storage capacity D1212: Up to 960 TB (96x 10 TB LFF NL SAS HDDs) D1224: Up to 1.47 PB (192x 7.68 TB SFF SAS SSDs) Host adapters RAID adapters: ServeRAID M5225 (2-port 12 Gb SAS;...
  • Page 6 Lenovo Storage D1224 SFF Chassis, Dual ESM, 9x 1.2TB 10K HDDs, 4x 0.5m SAS cables 4587E6U Lenovo Storage D1224 SFF, Dual ESM, 9x 1.2TB 10K HDDs, 2x 400GB SSDs, 4x 0.5m SAS cables 4587E2U Lenovo Storage D1224 SFF, Dual ESM, 9x 1.2TB 10K HDDs, 4x 400GB SSDs, 4x 0.5m SAS cables...
  • Page 7: Host Connectivity

    Port A on each ESM in the adjacent enclosure for daisy chaining. Up to eight D1212 or D1224 drive enclosures, or a combination of both, can be daisy-chained with support for up to four hosts attached to the chain. Without daisy-chaining, a standalone D1224 drive enclosure can support up to six directly attached hosts.
  • Page 8 The following figures illustrate different host connectivity topologies. Figure 5. Connectivity topology with one host Figure 6. Connectivity topology with two hosts Lenovo Storage D1212 and D1224 Drive Enclosures...
  • Page 9 The SAS zoning feature of the D1212 and D1224 specifies how multiple hosts access drives in the enclosures. If SAS zoning is disabled, all attached hosts can access all drives in the enclosures, which is typically used in standalone single-host or clustered multi-host environments, where all cluster nodes need access to all drives.
  • Page 10 The supported zone configurations are shown in the following table. Note: Mode 0 means that zoning is disabled. Table 4. D1212 and D1224 zoning configurations Maximum Drive bays Zoning Number number Zone Expansion mode of zones of hosts number Host ports...
  • Page 11 Drives The D1212 drive enclosure supports up to 12 LFF hot-swap drives, and the D1224 drive enclosure supports up to 24 SFF hot-swap drives. The following tables list drive options for the D1212 and D1224 drive enclosures. Table 6. LFF drive options...
  • Page 12: Power Cables

    01DC442 AU1S Lenovo Storage 2TB 7.2K 2.5" NL-SAS HDD 01DC437 AU1R 2.5-inch SAS hot-swap SSDs (1 DWD) Lenovo Storage 3.84TB 1 DWD 2.5" SAS SSD (1200.2) 01CX632 AV2F Lenovo Storage 3.84TB 1 DWD 2.5" SAS SSD (PM1633a) 01KP065 AVPA Lenovo Storage 7.68TB 1 DWD 2.5" SAS SSD (PM1633a)
  • Page 13: Physical Specifications

    Other power cable options are also available, and the part numbers and feature codes to order the power cables are listed in the following table (two power cables are required per each D1212 and D1224). Table 8. Power cable options...
  • Page 14: Operating Environment

    Table 9. Warranty service definitions Term Description Parts If a problem with your product cannot be resolved via telephone and a CRU part is required, Lenovo Delivered will send a replacement CRU to arrive at your location. Technician If a problem with your product cannot be resolved via telephone, a Service Technician will be Installed dispatched to arrive at your location.
  • Page 15: Regulatory Compliance

    Lenovo system. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles with Lenovo warranty upgrades and extensions.
  • Page 16: Raid Controllers And Hbas

    Reduction of Hazardous Substances (ROHS) UL/CSA IEC 60950-1 VCCI, Class A (Japan) RAID controllers and HBAs The D1212 and D1224 expansion enclosures are supported with the RAID adapters and HBAs that are listed in the following table. Table 10. RAID controllers and HBAs Maximum...
  • Page 17: Operating Systems

    ThinkServer RD450 (E5-2600 v3 and E5-2600 v4) ThinkServer RD550 (E5-2600 v3 and E5-2600 v4) ThinkServer RD650 (E5-2600 v3 and E5-2600 v4) For RAID adapters and HBAs support details for a particular server, refer to a Lenovo Press product guide for the server, found at: http://lenovopress.com...
  • Page 18: Rack Cabinets

    For information about operating compatibility with System x and ThinkServer systems, refer to the Operating System Interoperability Guide: http://lenovopress.com/osig Rack cabinets The following table lists the rack cabinets that are offered by Lenovo that can be used in D1212 and D1224 storage expansion solutions. Table 12. Rack cabinets Description...
  • Page 19: Power Distribution Units

    Power distribution units The following table lists the power distribution units (PDUs) that are offered by Lenovo that can be used in D1212 and D1224 storage expansion solutions. Table 13. Power distribution units Part Description number 0U Basic PDUs 0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord...
  • Page 20: Uninterruptible Power Supply Units

    For more information, see the list of Product Guides in the PDU category: http://lenovopress.com/servers/options/pdu Uninterruptible power supply units The following table lists the uninterruptible power supply (UPS) units that are offered by Lenovo that can be used in D1212 and D1224 storage expansion solutions. Table 14. Uninterruptible power supply units...
  • Page 21: Related Publications And Links

    For you, this dedication provides a high-quality, easy, and positive financing experience. For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website: http://www.lenovofs.com...
  • Page 22 Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead.
  • Page 23 Trademarks Lenovo, the Lenovo logo, and For Those Who Do are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at http://www.lenovo.com/legal/copytrade.html. The following terms are trademarks of Lenovo in the United States, other countries, or both: Lenovo®...

This manual is also suitable for:

D1224

Table of Contents