IBM Storwize V5000 Gen2 Quick Installation Guide GC27-8581-00...
Page 2
The information in the “Safety and environmental notices” on page ix v The information in the IBM Environmental Notices and User Guide (provided on a DVD) This edition applies to IBM Storwize V5000 and is valid until replaced by new editions.
. xvii Storwize V5000 Gen2 library and related Appendix A. Accessibility features for publications . . xvii IBM Storwize V5000 ..47 How to order IBM publications . xix Related websites . xix Appendix B.
Example of a Storwize V5010 system with a control enclosure . 4-port Ethernet host interface adapter . . 33 Rear view of a Storwize V5000 Gen2 expansion Example Storwize V5010 configuration with 10 enclosure. Gbps iSCSI-FCoE 4-port host interface adapters 34...
In the preceding examples, the numbers (C001) and (D002) are the identification numbers. 2. Locate the IBM Systems Safety Notices with the user publications that were provided with the Storwize V5000 Gen2 hardware. 3. Find the matching identification number in the IBM System Storage Storwize V5000 Gen2 Safety Notices .
“Labels” section. Note: You can find and download the current IBM System Safety Notices by searching for Publication number G229-9054 in the IBM Publications Center.
Page 11
CAUTION: The battery contains lithium. To avoid possible explosion, do not burn or charge the battery. Do not: Throw or immerse into water, heat to more than 100°C (212°F), repair or disassemble. (C003) CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during a relocation.
(R009) Danger notices for Storwize V5000 Gen2 Ensure that you are familiar with the danger notices for Storwize V5000 Gen2 . Use the reference numbers in parentheses at the end of each notice, such as (C003) for example, to find the matching translated notice in IBM Systems Safety Notices.
Page 13
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied a power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
Do not attempt to lift any objects that weigh more than 18 kg (40 lb) or objects that you think are too heavy for you. v Do not perform any action that causes a hazard or makes the equipment unsafe. Storwize V5000 Gen2: Quick Installation Guide...
v Before you start the device, ensure that other personnel are not in a hazardous position. v Place removed covers and other parts in a safe place, away from all personnel, while you are servicing the unit. v Keep your tool case away from walk areas so that other people cannot trip over v Do not wear loose clothing that can be trapped in the moving parts of a device.
Environmental notices This information contains all of the required environmental notices for IBM Systems products in English and other languages. The IBM Systems Environmental Notices (http://ibm.co/1fBgWFI) information includes statements on limitations, product information, product recycling and disposal, battery information, flat panel display, refrigeration and water-cooling systems, external power supplies, and safety data sheets.
Table 3 lists websites that provide publications and other information about the ® Storwize V5000 Gen2 or related products or technologies. The IBM Redbooks publications provide positioning and value guidance, installation and implementation experiences, solution scenarios, and step-by-step procedures for various products.
How to get information, help, and technical assistance If you need help, service, technical assistance, or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you. About this guide...
Page 20
Before calling for support, be sure to have your IBM Customer Number available. If you are in the US or Canada, you can call 1 (800) IBM SERV for help and service. From other parts of the world, see http://www.ibm.com/planetwide for the number that you can call.
Page 21
At times, you might need expert advice about using a function provided by the system or about how to configure the system. Purchasing the IBM Support Line offering gives you access to this professional advice while deploying your system, and in the future.
2. The steps in Chapter 2, “Installing the Storwize V5000 Gen2 hardware,” on page 19 involve installing the hardware and attaching the data cables and power cords.
Complete these steps for each control enclosure and expansion enclosure that you add. Be familiar with the following information v See “Caution notices for the Storwize V5000 Gen2” on page x and “Danger notices for Storwize V5000 Gen2” on page xii for a summary of the situations that can be potentially hazardous to you.
Page 25
v Use safe practices when lifting. The fully populated enclosure weighs about 26 kg (57 lbs). At least two people are required to lift and install the enclosure into the rack or to remove an enclosure from the rack.The fully populated enclosure weighs about 37 kg (82 lbs).
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: – If IBM supplied a power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
12-slot Control enclosure for 2.5-inch drives 2078–324 3 years 24-slot Control enclosure for 2.5-inch drives __ v All Storwize V5000 Gen2 systems support the expansion enclosures that are listed in Table 7 on page 6. Chapter 1. Before you begin the installation...
Table 7. Storwize V5000 Gen2 expansion enclosures Machine IBM Storwize V5000 Gen2 Model Warranty Description type / model 2077-12F 1 year 12-slot Expansion enclosure for 3.5-inch drives 2077-24F 1 year 24-slot Expansion enclosure for 3.5-inch v Storwize V5010 drives v Storwize V5020...
Identify the hardware components The following graphics identify the hardware components and port locations for the control enclosure and expansion enclosure on Storwize V5000 Gen2 systems. Control enclosure components The following figures show the rear view of the control enclosures on Storwize V5000 Gen2 systems.
Figure 5. Data ports on the rear of the Storwize V5020 control enclosure Figure 6 shows the data ports on the back of a Storwize V5030 node. Figure 6. Data ports on the rear of the Storwize V5030 control enclosure Storwize V5000 Gen2: Quick Installation Guide...
Port 1 is used to connect to a SAS expansion port on a node canister or port 2 of another expansion canister. Figure 8. SAS ports and LEDs in rear view of a Storwize V5000 Gen2 expansion canister Support rails and enclosures Storwize V5000 Gen2 systems use the same rails and enclosures for both control and expansion enclosures.
Figure 9. Enclosure support rails on Storwize V5000 Gen2 Direct current power supply units When feature code AHPB is used, a direct current (DC) power supply can be installed in a Storwize V5000 Gen2 enclosure. This section describes the additional information you need to know when using the DC power models.
Page 33
Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v If IBM supplied a power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
Page 34
The required circuit breaker rating is 20 amps. DC power supply unit connectors and indicators Each Storwize V5000 Gen2 enclosure can contain two DC power supply units. Each power supply unit can provide power to the whole enclosure. The power supply units have the components that are shown in Figure 10 on page...
Not used. Connecting a DC power supply to a DC power source A Storwize V5000 Gen2 enclosure that is DC powered contains two DC power supply units (PSUs). Each unit must be connected to a suitable -48V DC power source. To provide redundancy in a power circuit failure, connect the two PSUs to different DC power sources.
Use the supplied cables to connect the DC PSUs to the power sources. Use only the IBM supplied DC power cable (IBM part number 00AR087) to connect the unit to a DC power source. Each PSU cable must be protected by a 20A circuit breaker. These instructions assume that the circuit breaker is separate from the DC power distribution unit.
Table 11. Direct current power replaceable units Description FRU part number Customer replaced Direct current power supply 00AR231 Direct current power cable 00AR087 The procedure to remove and replace the DC power supply unit is the same as the AC power supply procedure. When replacing the DC power cable, follow the instructions for disconnecting cables from the DC power distribution unit.
The environmental and electrical requirements for the physical site must be met to ensure that your system works reliably. Before installing a Storwize V5000 Gen2 system, you must verify that adequate space in a suitable rack is available. You must also ensure that the requirements for power and environmental conditions are met.
Page 39
v Add the fourth expansion directly above the second, and so on. Chapter 1. Before you begin the installation...
Installing support rails for Storwize V5000 Gen2 systems Storwize V5000 Gen2 systems use the same rails for control and expansion enclosures. Before you install a control or expansion enclosure, you must first install the support rails for it.
3. Working at the front of the rack cabinet, identify the two standard rack units (2U) of space in the rack into which you want to install the support rails. Figure 13 on page 21 shows two rack units with the front mounting holes identified. Storwize V5000 Gen2: Quick Installation Guide...
Unscrew the medium pins and replace with the large pins supplied with the rails. 5. At each end of the rail, grasp the tab and pull firmly to open the hinge bracket. (See Figure 14 on page 22.) Chapter 2. Installing the Storwize V5000 Gen2 hardware...
11. Secure the rear of the rail to the rear rack flange with an M5 screw. 12. Repeat the steps to secure the opposite rail to the rack cabinet. 13. Repeat the procedure to install rails for each additional control enclosure. Storwize V5000 Gen2: Quick Installation Guide...
(see Figure 17 on page 24). Note: The rails are not designed to hold an enclosure that is partially inserted. The enclosure must always be in a fully inserted position. Chapter 2. Installing the Storwize V5000 Gen2 hardware...
Rotate the end cap down until it snaps into place. d. Ensure that the inside surface of the end cap is flush with the chassis. Connecting SAS cables to Storwize V5000 Gen2 expansion enclosures If you have installed expansion enclosures, you must connect them to a Storwize V5000 Gen2 control enclosure.
Page 47
Connect SAS port 1 of the right node canister in the control enclosure to SAS port 1 of the right expansion canister in the first expansion enclosure. Figure 18 on page 26 shows how to connect SAS cables on a Storwize V5010 system. Chapter 2. Installing the Storwize V5000 Gen2 hardware...
Figure 18. Connecting the SAS cables to a Storwize V5010 system Figure 19 on page 27 shows how to connect SAS cables on a Storwize V5020 system. Storwize V5000 Gen2: Quick Installation Guide...
Figure 19. Connecting the SAS cables to a Storwize V5020 system Figure 20 on page 28 shows how to connect SAS cables on a Storwize V5030 system. In this figure, two expansion chains are connected to the Storwize V5030 system. Chapter 2. Installing the Storwize V5000 Gen2 hardware...
Note: Storwize V5010 and Storwize V5020 systems support only one expansion chain. a. Connect SAS port 2 of the left node canister in the control enclosure to SAS port 1 of the left expansion canister in the second expansion enclosure. Storwize V5000 Gen2: Quick Installation Guide...
For Storwize V5030 systems only, no more than 10 expansion enclosures can be chained to SAS port 2 of a node canister. The expansion enclosures in this chain should be installed above the control enclosure. Chapter 2. Installing the Storwize V5000 Gen2 hardware...
Refer to “Connecting SAS cables to Storwize V5000 Gen2 expansion enclosures” on page 24 for examples of SAS cable connections on each Storwize V5000 Gen2 system. Connecting Ethernet cables to node canisters The control enclosures on Storwize V5000 Gen2 systems have several Ethernet ports on the rear of each node canister.
In Figure 24 on page 32, the technician port is identified by the green cable. Note: Never use the technician port to provide an Ethernet connection to the system. Do not connect the Ethernet technician port to a network Chapter 2. Installing the Storwize V5000 Gen2 hardware...
Ethernet cables to connect the system to your Ethernet SAN. About this task Each Storwize V5000 Gen2 system has two Ethernet ports, port 1 and port 2, that are built into the canister. When a 4-port Ethernet host interface adapter is installed, the port number starts at 3.
To provide redundant connectivity, connect both node canisters in a control enclosure to the same networks. Results Figure 26 on page 34 shows an example Storwize V5010 configuration that uses 10 Gbps iSCSI-FCoE 4-port host interface adapters. Chapter 2. Installing the Storwize V5000 Gen2 hardware...
Connecting Fibre Channel cables to a Fibre Channel host interface adapter If your Storwize V5000 Gen2 system has 16 Gbps Fibre Channel 4-port host interface adapters installed, you can use Fibre Channel cables to connect them to your Fibre Channel SAN.
Storwize V5010 or Storwize V5030 systems. About this task Two types of SAS cables are used for host attachment, depending on the requirements of the host. v Mini SAS HD to Mini SAS HD (Figure 31 on page 37) Storwize V5000 Gen2: Quick Installation Guide...
To install the cables, complete the following steps. 1. Connect the required number of SAS cables. Refer to the “Planning” section of the IBM Knowledge Center for instructions on determining the number of cables required. Note: When connecting to the SAS ports on the left side of the node canister, each host must be connected to both canisters.
Figure 33 shows the location of the onboard 12 Gbps SAS ports on a Storwize V5020 system. In this example, the optional 4 port 12 Gbps SAS host adapter is also installed. SAS HOST Figure 33. Location of available SAS ports on a Storwize V5020 system Storwize V5000 Gen2: Quick Installation Guide...
The enclosure does not have power switches. Note: Each enclosure has two power supply units. To provide power failure redundancy, connect the two power cords to separate power circuits. Chapter 2. Installing the Storwize V5000 Gen2 hardware...
The canister is ready with no critical errors when Power is illuminated, Status is flashing, and Fault is off. If a canister is not ready, refer to the “Procedure: Understanding the system status using the LEDs” topic in “Troubleshooting”. Storwize V5000 Gen2: Quick Installation Guide...
Microsoft Internet Explorer (IE) 11 and Microsoft Edge v Google Chrome 46 IBM supports higher versions of the browsers if the vendors do not remove or disable function that the product relies upon. For browser levels higher than the versions that are certified with the product, customer support accepts usage-related and defect-related service requests.
Page 64
3. Enable file download on IE 10 and 11 running on Windows 2012. a. In Internet Explorer, click Tools > Internet Options. b. On the Internet Options window, select the Security tab. c. On the Security tab, click the Internet zone. Storwize V5000 Gen2: Quick Installation Guide...
User name and password for system initialization During the initialization procedure, you need to log in to the management GUI for the Storwize V5000 Gen2 system. The default user name and password for the management GUI are listed in Table 14.
Figure 36. Storwize V5010 technician port Figure 37. Storwize V5020 technician port Storwize V5030 systems have a dedicated technician port. Figure 38 on page 45 shows the location of the port ( T ). Storwize V5000 Gen2: Quick Installation Guide...
Figure 38. Storwize V5030 technician port 4. Connect an Ethernet cable between the port of the personal computer that is configured in step 2 on page 44 and the technician port. After the connection is made, the system will automatically configure the IP and DNS settings for the personal computer if DHCP is available.
Fibre Channel or FCoE ports to connect to each other. 5. Start the management GUI. 6. Go to Monitoring > System. 7. On the System page, select Actions > Add Enclosures. 8. Continue to follow the on-screen instructions. Storwize V5000 Gen2: Quick Installation Guide...
Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
Page 74
The materials at those websites are not part of the materials for this IBM product and use of those websites is at your own risk. IBM may use or distribute any of the information you provide in any way it believes appropriate without incurring any obligation to you.
IBM, therefore, cannot guarantee or imply reliability, serviceability, or function of these programs. The sample programs are provided "AS IS", without warranty of any kind. IBM shall not be liable for any damages arising out of your use of the sample programs.
Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-IBM option cards. Attention: This is an EN 55022 Class A product. In a domestic environment this product might cause radio interference in which case the user might be required to take adequate measures.
Klasse A ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung der IBM verändert bzw.
Japan VCCI Council Class A statement This explains the Japan Voluntary Control Council for Interference (VCCI) statement. Japan Electronics and Information Technology Industries Association Statement This statement explains the Japan JIS C 61000-3-2 product wattage compliance. See Knowledge Center Storwize V5000 Gen2: Quick Installation Guide...
This statement explains the Japan Electronics and Information Technology Industries Association (JEITA) statement for products less than or equal to 20 A per phase. This statement explains the JEITA statement for products greater than 20 A, single phase. This statement explains the JEITA statement for products greater than 20 A per phase, three-phase.
Page 82
Storwize V5000 library related publications xvii superuser 43 Taiwan contact information 56 electronic emission notice 56 technical assistance xx trademarks 53 user name 43 web browsers configuring 41 requirements 41 websites xix Storwize V5000 Gen2: Quick Installation Guide...