Panasonic WV-SUD638 Installation Manual
Hide thumbs Also See for WV-SUD638:

Advertisement

Quick Links

Installation Guide
Included Installation Instructions
Network Camera
WV-SUD638
Model No.
(Natural silver)
WV-SUD638-H / WV-SUD638-T
(Gray)
(Brown)
During upright position
During fore position
• This manual describes the installation procedures, network camera installation, cable connec-
tions, and adjustment.
• Before reading this manual, be sure to read the Important Information (included in the CD-ROM).
For U.S. and Canada:
For Europe and other countries:
Panasonic Corporation
Panasonic System Communications
Company of North America,
http://www.panasonic.com
Unit of Panasonic Corporation
of North America
www.panasonic.com/business/
Panasonic Corporation
For customer support, call 1.800.528.6747
Osaka, Japan
Two Riverfront Plaza, Newark, NJ 07102-5490
Authorised Representative in EU:
Panasonic Canada Inc.
Panasonic Testing Centre
5770 Ambler Drive, Mississauga,
Panasonic Marketing Europe GmbH
Ontario, L4W 2T3 Canada
Winsbergring 15, 22525 Hamburg, Germany
(905)624-5010
www.panasonic.ca
© Panasonic Corporation 2017
fles0816-1057 PGQX2063YA Printed in China
Parts and functions
Dummy cover or IR LED unit
Camera
Sun Shade
(optional)
Tilt arm
Dummy cover
or IR LED unit
(optional)
Front glass
Wiper
Tilt lock
PAN
rotation part
Waterproof
EXT I/O
connector
Side cover
Mounting
pedestal
Mounting pedestal
fixing screws ×4
(locally procured)
Bottom wiring port
Side wiring port*
*1 The female thread for conduit is compliant with ANSI NPSM (parallel pipe threads) 3/4 or
ISO 228-1 (parallel pipe threads) G3/4.
STATUS indicator behaviors
• When the power is turned on
Lights orange → Lights off → Blinks orange → Lights orange (When the network connection is not established)
Lights orange → Lights off → Blinks orange → Blinks green → Lights green
(When the network connection is established)
• During the standby or connection
Lights orange (When the cable is not connected)
LINK indicator
Lights green (When the cable is connected)
• During the upgrade process
Blinks orange
ACT Indicator
• During the initialization
Lights orange → Lights off → Blinks orange →
STATUS indicator
Lights orange
• Port forwarding error caused by the UPnP function
Blinks orange (in 2 seconds intervals
INITIAL SW
(on for 1 second / off for 1 second))
(Initial switch)
• Trouble happening on the camera
Blinks red
Switch plate
• When the installation position is abnormal
Lights red
Standard accessories
Important safety instructions ......................... 1 pc.
Warranty card*
Installation Guide (this document) ................. 1 set
CD-ROM*
Code label*
*1 This product comes with several types of warranties. Each warranty is only applicable to the prod-
ucts purchased in the regions indicated on the relevant warranty.
*2 The CD-ROM contains the operating instructions and different kinds of tool software programs.
*3 This label may be required for network management. The network administrator shall retain the code label.
Waterproof power supply connector (plug side) ...............................................................................1 set
Waterproof EXT I/O connector (plug side) ........................................................................................1 set
Waterproof RJ45 connector (plug side) ............................................................................................1 set
Washer nozzle mounting bracket A ..................................................................................................1 pc.
Washer nozzle mounting bracket B..................................................................................................1 pc.
Fixing screws for the washer nozzle mounting bracket B ..............................3 pcs. (of them, 1 for spare)
Attachment plate .............................................................................................................................1 pc.
Fixing screws for attachment plate ................................................................. 5 pc. (of them, 1 for spare)
Fixing nuts for attachment plate ..................................................................... 5 pc. (of them, 1 for spare)
Spring washer ............................................................................................... 5 pc. (of them, 1 for spare)
Flat washer .................................................................................................. 10 pc. (of them, 2 for spare)
Safety wire .......................................................................................................................................1 pc.
Wire clamper ...................................................................................................................................1 pc.
Bit (Hex wrench, screw size 6.35 mm {1/4 inches} T20)...................................................................1 pc.
Installation procedure
56789
Cable preparation
• Attach the provided waterproof connector to the cable to be wired to the inside of the ceiling or
floor or along various surfaces, and run the cable through the conduit. (Please choose a conduit
of a suitable size to allow the connector to pass through.)

Installation
• Remove the side cover of the camera so that the wire connection part is visible. (Step.4)
• If necessary, install the extension unit (IR LED unit) (optional) if necessary. (Step.5)
• If you want to shoot the foot area, bend the tilt arm of the camera forward. (Step.6)
• Fix the camera onto the installation location. (Step.8)
* Install the washer nozzle mounting bracket pre-fitted with a (recommended) washer nozzle at the
same time.

Connecting wires
• Connect each waterproof connector to the camera, and fix the side cover back to its original position.
Configuring the camera so that it can be accessed from a PC
• Turn on the power supply, and configure the camera so
that it can be accessed via network.
• About the INITIAL SW (Initial switch)
Follow the steps below to initialize the network camera.
Cut the power supply to the camera either by unplugging the AC power cord or by turning off the
power supply of the tested PoE injector.
Turn on the power of the camera while holding down the INITIAL SW, and keep the INITIAL SW held
down for 10-15 seconds. In about 2 minutes after releasing the INITIAL SW, the camera will start up
and the settings, including the network settings, will be initialized.
IMPORTANT:
• When the camera is initialized, the settings including the network settings will be initialized. Note that the
CRT key (SSL encryption key) used for the HTTPS protocol and the preset entry will not be initialized.
• Before initializing the settings, it is recommended to write down the settings in advance.
• Do not turn off the power of the camera during the process of initialization. Otherwise, it may
fail to initialize and may cause malfunction.
System connection diagram
Waterproof
RJ45
The camera can be powered by the AC power supply or the tested PoE injector as shown in the follow-
connector
ing illustration.
Waterproof
power supply
Hub/Router
connector
Ethernet cable (category
5e or better, straight)
PC*
2
1
Tested PoE injector*
1
Ethernet cable (category 5e or better, straight)
*1 For the related information on applicable tested PoE injectors, refer to our website
(http://security.panasonic.com/support/info/).
*2 Use an Ethernet cable (category 5e or better, cross) when directly connecting the camera to a PC.
3
Cable preparation
............................................ 1 set
Attach the provided waterproof connector to the cable to be connected to the camera.
1
2
.................................................... 1 pc.
* When a conduit is used for wiring, always check its size before installing the waterproof connector.
3
.................................................. 1 pc.
Otherwise, the cable may not be able to pass through the conduit depending on the number of cables
used and the waterproof connector in use.
* Always make preparations before the procedure "[3] Attach the waterproof RJ45 connector (acces-
sory) to the Ethernet cable."
* Prepare [1] and [2] when necessary.
[1] Attach the waterproof EXT I/O connector (accessory) to the cable
* The parts to be used in
and
<Locally procured items>
• Multi-core cable
Size of the internal lead wire
• Manual crimping tool
• Extraction tool (if necessary)
Thread each part of the waterproof EXT I/O connector (accessory) through the cable in
sequence
Pass the cord tube, cord clamp, gasket, spring and coupling in sequence through the plug beforehand.
Prepare wire ends according to the dimensions shown in the illustration below.
Case block
Coupling
2.0 mm (+0, -0.5)
15 ~ 20 mm {19/32 ~ 25/32 inches}
{3/32 (+0, -1/32) inches}
Crimp the contact (accessory) to the cable
Insert the contact into the terminal hole on the
case block
• After inserting the contact, pull the lead wire lightly,
and ensure that it is firmly fixed to the terminal hole
of the waterproof EXT I/O connector.
<Pin layout of the waterproof EXT I/O connector>
Pin. 1 LINE IN
Pin. 2 Audio/LINE_GND
Pin. 3 Audio OUT
(→ Refer to the leaflet "Configuring
the camera so that it can be
Pin. 4 Alarm GND
accessed from a PC")
Pin. 5 Alarm IN3/AUX
Pin. 6 Alarm IN2/Alarm OUT
2
[2] Attach the waterproof power supply connector (accessory) to the cable
* The parts to be used in
and
are in the bag of the waterproof power supply connector (plug side) set.
<Locally procured items>
• Power cable
Cable diameter
Cross-sectional area of the wire conductor
Number of wires
Insulation material
Preparations
• Assemble the internal strain relief as shown in the right illustration,
and install the fixing bracket.
(Tighten the screws temporarily as the power cord will go in between
the bracket and the formed part.)
• Install the mounting gasket on the clamp
ring as shown in the right illustration. (Please
use the applicable parts as described below
for the mounting gasket according to the
external diameter of the power cord.)
Small internal diameter...
Power cord size 6.0 ~ 9.0 mm {1/4 ~ 11/32 inches}
Large internal diameter...
Power cord size 9.0 ~ 10.0 mm {11/32 ~ 13/32 inches}
Thread each part of the waterproof power supply connector through the power cable in
the sequence as shown in the illustration below
• Cable nut
Clamp ring (with mounting gasket)
Back shell
Internal strain relief
AC100-240 V
50/60 Hz
Prepare the cable end in the following dimensions, and twist the core.
Process tolerance: +1 mm/-0 mm {+1/32 / -0 inches}
Dimensions A (cable sheath)
Live, Neutral
18 mm {23/32 inches}
GND
20 mm {25/32 inches}
While the core of the lead wire is inserted into the connecting hole at the back of the
connector body, tighten the screw on the connector body, and connect
and fix the lead wire to each terminal.
For safety purpose, please read the following connection instructions carefully.
* There is a cutout on the connector coupling nut.
Align the position of the screw to be tightened with the cutout on the coupling
nut, and tighten the screw with a flathead screwdriver. (Refer to the upper
right illustration.)
(Recommended tightening torque: 0.5 N·m {0.37 lbf·ft}
4
Mount the coupling and the spring on the case block, and tighten the cord tube with the gasket
and the cord clamp
• Align the mark "
with the side of pin
and install the coupling and the spring in
sequence.
• Shift the cord tube, and insert the cord
clamp and the gasket in the cord tube.
• Align the cord tube with the coupling part,
and rotate to tighten them as shown in the
are in the bag of the waterproof EXT I/O connector (plug side) set.
right illustration. (Recommended tightening
torque: 0.5 N·m {0.37 lbf·ft})
ø6.2 ~ 7 mm {ø1/4 ~ 9/32 inches}
AWG26 – AWG30, coated external diameter of ø1 mm {ø1/32 inches} or below
HT-102/HR30-1, made by Hirose Electric Co., Ltd.
HR30-TP, made by Hirose Electric Co., Ltd.
Connect the washer unit (locally procured)
Spring
Cord clamp
Gasket
Cord tube
Cable
Case block
Nozzle
* Please use the washer unit that has been insulated from the commercial AC power.
EXT I/O terminal ratings
• Alarm IN1, Alarm IN2, Alarm IN3
Waterproof EXT I/O connector (accessory)
Input specification: No-voltage make contact input (4 V ~ 5 V DC, internally pulled up)
Terminal layout of the contact insertion side
• Alarm OUT, AUX OUT
Pin. 7
Alarm IN1
Output specification: Open collector output (maximum applied voltage: 20 V DC)
Pin. 8
N.C.
Pin. 9
Relay-
• Max. ratings of Relay+ and Relay-: DC 25 V, 4.0 A
Pin. 10 Relay-
* The default of EXT I/O terminals is "Off".
Pin. 11 Relay+
Pin. 12 Relay+
5
Connector Pin 1 Live
Fixing bracket
(accessory)
Internal strain
ø6 ~ 10 mm {ø1/4 ~ 13/32 inches}
relief (accessory)
0.75 or 1.25 mm
{0.0012 or 0.0019 inche
}
2
2
3 (for L, N and FG)
Polyethylene (recommended)
Screws x 2
(accessory)
Small internal
Clamp ring
diameter
Insert and fix the internal strain relief on the connector as shown in the illustration. Next,
rotate the screw of the internal strain relief, and fix the power cord firmly with the fixing
Mounting
bracket.
gasket
(Recommended tightening torque: 0.5 N·m {0.37 lbf·ft})
Large internal
Align the coupling nut to the fixing position to prevent
diameter
the connector from rotating, and rotate to fix the back
shell. Install the clamp ring (with mounting gasket) on
the back shell, and tighten it with a cable nut.
(Recommended tightening torque: 1.5 ~ 2.0 N·m {1.11 ~ 1.48 lbf·ft}
Back shell
Internal strain relief
Cable
Clamp ring (with
Cable nut
mounting gasket)
Dimensions B (bare core wire)
7 mm {9/32 inches}
9 mm {11/32 inches}
Connector body
7
Pin
Coupling
" on the coupling
of the case block,
Spring
Case block
Cord tube (Including the cord clamp and the gasket)
Waterproof EXT I/O
Washer unit connection
connector side
terminal side
Circuit diagram
Pin. 9
Relay-
Washer-
Pin. 10 Relay-
Pin. 11 Relay+
Washer+
Pin. 12 Relay+
Washer hose
OFF: Open or 4 V ~ 5 V DC
ON: Make contact with GND (required drive current: 1 mA or more)
OPEN: 4 V ~ 5 V DC by internal pull-up
CLOSE: Output voltage 1 V DC or less (maximum drive current: 50 mA)
6
Pin 2 Neutral
Pin 3 N.C.
GND
Pin 2
Cutout
Pin 3
Pin 1
GND
Coupling nut
Screws × 2
Internal strain relief
Clamp ring
Coupling nut
Back shell
(with mounting gasket)
Cable nut
8

Advertisement

loading

Summary of Contents for Panasonic WV-SUD638

  • Page 1 (Recommended tightening <Locally procured items> Waterproof RJ45 connector (plug side) ....................1 set torque: 0.5 N·m {0.37 lbf·ft}) WV-SUD638-H / WV-SUD638-T • Multi-core cable ø6.2 ~ 7 mm {ø1/4 ~ 9/32 inches} Washer nozzle mounting bracket A ....................1 pc.
  • Page 2: Connecting Wires

    Use 4 pairs (8 pins in total). In accordance with the conditions of the installation location, prepare the foundation of the installation the camera (on the Panasonic logo side). mounting holes at the bottom of the camera. Max. length: 100 m [328 ft]; external diameter: ø5 mm ~ 6.5 mm {ø3/16 ~ 1/4 inches} site, fix the installation support and the installation stand, and prepare for cable wiring.

This manual is also suitable for:

Wv-sud638-hWv-sud638-t