Vacon NX User Manual
Hide thumbs Also See for NX:

Advertisement

vacon nx
®
ac drives
endat/ssi, sin-cos option board, opt-be
sin-cos option board, opt-ak
sin-cos with pulse output option board, opt-ar
user manual

Advertisement

Table of Contents
loading

Summary of Contents for Vacon NX

  • Page 1 ® ac drives endat/ssi, sin-cos option board, opt-be sin-cos option board, opt-ak sin-cos with pulse output option board, opt-ar user manual...
  • Page 2: Table Of Contents

    INDEX Document code: DPD01174 Date edited: 01.02.2013 ENDAT/SSI, Sin-Cos Option Board OPT-BE ................ 3 OPT-BE layout and description ....................3 OPT-BE jumpers ........................4 OPT-BE LEDs ..........................5 I/O terminals on OPT-BE, encoder terminal X6 ............... 5 OPT-BE Parameters ......................... 6 OPT-BE monitored values ......................
  • Page 3: Endat/Ssi, Sin-Cos Option Board Opt-Be

    (Board Status LED) Green LED (Encoder LED) Description: EnDat/SSI Encoder board for Vacon NXP with an input for absolute encoder Sin/Cos type encoder. Allowed slots: B, C, D, E (Sin/Cos signals can only be used in slot C) Type ID:...
  • Page 4: Opt-Be Jumpers

    4 • VACON Installation EnDat is a bidirectional synchronous serial interface for encoders. For example, the absolute encoder position data can be read and encoder parameters can be set via the EnDat connection. It also forwards the messages related to the encoder functions.
  • Page 5: Opt-Be Leds

    Analog Sin/Cos signals deserve some more precautions for noise immunity than pulse encoders. Use of shielded pair cables is recommended. Use one pair for SIN+/SIN- and another pair for COS+/COS- signals. 24-hour service: +358 (0)40 8371 150 • Email: vacon@vacon.com...
  • Page 6: Opt-Be Parameters

    6 • VACON Installation OPT-BE Parameters Number Parameter Default Note 4= EnDat + Sin/Cos (default) 5= EnDat Only 6= SSI+Sin/Cos 7= SSI Only 8= Sin/Cos Only Note: In modes 5 and 7, only the 7.x.1.1 Operating Mode absolute serial information is used. In modes 4 and 6, also Sin/Cos signals are used.
  • Page 7: Sin-Cos Option Board Opt-Ak

    • 7 SIN-COS OPTION BOARD OPT-AK OPT-AK layout and description Description: Sin/Cos Encoder board for Vacon NXP with an input for type encoder. Programmable control voltage. Allowed slots: C (Sin/Cos signals can only be used in slot C) Type ID:...
  • Page 8: Opt-Ak Jumper Settings

    8 • VACON Installation OPT-AK jumper settings NOTE! With +5 V supply voltage, voltage drop with long cabling (about 60 m with 0.5 mm wire section) can become too big for reliable operation. Using +12 V or +15 V encoders is recommended in these cases.
  • Page 9: Opt-Ak Parameters

    7.3.1.3 Interpolation the encoder accuracy 0=No 1=Yes OPT-AK monitored values Code Monitored value Unit Description 7.3.2.1 Encoder frequency Encoder frequency in Hz 7.3.2.2 Encoder speed Encoder Speed in rpm 24-hour service: +358 (0)40 8371 150 • Email: vacon@vacon.com...
  • Page 10: Sin-Cos With Pulse Output Option Board Opt-Ar

    Installation SIN-COS WITH PULSE OUTPUT OPTION BOARD OPT-AR OPT-AR layout and description Description: Sin/Cos Encoder board for Vacon NXP with an input for type encoder. Programmable control voltage for encoder. Differential two channel pulse output. Allowed slots C (Sin/Cos signals can only be used in slot C)
  • Page 11: Opt-Ar Jumper Settings

    NOTE! Analog Sin/Cos signals deserve some more precautions for noise immunity than pulse encoders. Use of shielded pair cables is recommended. Use one pair for SIN+/SIN- , one pair for COS+/COS- and another pair for R+/R- signals. 24-hour service: +358 (0)40 8371 150 • Email: vacon@vacon.com...
  • Page 12: I/O Terminals On Opt-Ar, Pulse Output X3

    12 • VACON Installation I/O terminals on OPT-AR, pulse output X3 Terminal Technical data Incremental differential pulse output square wave, signal level RS-422 Impedance 120Ω Output current max. 50mA Max. output frequency 200KHz Output short/grounding protection Same as A+/A- OPT-AR parameters...
  • Page 13: Installation

    WARNING! Installing option boards Option boards OPT-BE, OPT-AK and OPT-AR can only be used with Vacon NXP drives. OPT-AK and OPT-AR can be connected to slot C. OPT-BE board can be connected to slots B, E, C or D, but Sin/Cos signals can only be used in slot C. If OPT-BE board is connected to slots B, E or D, the Sin/Cos signals have to be disconnected using the jumpers (see chapter 1.2).
  • Page 14 14 • VACON Installation Open the cover of the control unit. Install the option board in correct slot on the control board of the frequency converter. Make sure that the grounding plate fits tightly in the clamp. Strip the cable at such distance from the terminal that you can fix it to the frame with the grounding clamp.
  • Page 16 Find your nearest Vacon office on the Internet at: www.vacon.com Manual authoring: documentation@vacon.com Document ID: Vacon Plc. Runsorintie 7 65380 Vaasa Finland Subject to change without prior notice Rev. A © 2013 Vacon Plc.

This manual is also suitable for:

Nxp