Raisecom Technology Co., Ltd 1. Cautions Please read the following notices carefully before installing and using the device, Raisecom does not respond to any loss that caused by violating safety notices. RC952-FEE1-BL is integrated equipment. Move carefully and do not disassemble or mend it without the guidance of Raisecom technical engineer with the anti-static procedures.
E1. This equipment may be used in point-to-point topology, it can be network managed with RC series equipment. RC952-FEE1-BL interface converter is installed in 16-slot or 4-slot chassis of Raisecom. RC952-FEE1-BL also can be installed in 1-slot chassis used as remote standalone equipment; it works with local equipment to realize remote network management.
Raisecom Technology Co., Ltd 3. How to use 3.1. Introduction of Front Panel 100M 3.1.1. The indicator indicates E1 link indicators: LOS (Red) : Receiving signal loss alarm of local E1 link, LOS-On, without LOS-Off. LER (Double Color): The rest local alarm. AIS—Flashing with red color, LOF—On with yellow color, CRC—Flashing with yellow color, no alarm—Off.
Raisecom Technology Co., Ltd received. 100M (Green): 100M-On, 10M-Off. FDX (Green): On, Ethernet is working on full duplex mode Flashing, there is collision on half duplex mode. Power Indicator: PWR (Green): Steady ON, power supply is working in normal condition.
Humidity: 5%~90% non-condensing Power Consumption: 3W 3.3. Indication of Switch Setting There are five 8-bit Dip-switches SW1~SW5 on the RC952-FEE1-BL rear panel, there are one 4-bit Dip-switches SW6 on the front panel. Please setup the Dip-switches before the device powered on.
MDI/MDIX capability is opened at the same time. Ethernet interface has 10/100M auto-sensing capability. If connected Ethernet interface mode of switch, hub and network-card is fixed, then the Ethernet working mode of RC952-FEE1-BL is half-duplex. When the auto-sensing capability of Ethernet interface is closed, the auto MDI/MDIX capability is closed at the same time.
Raisecom Technology Co., Ltd working mode is slave. When the working mode of RC952-FEE1 is slave mode. Working status only can be checked by network management software, it can not be configured. bit: Clock mode switch On=Slave clock mode Off=Master clock mode (default) If there is timing equipment in E1 link, RC952-FEE1 of both sites must be set slave clock mode.
Raisecom Technology Co., Ltd TS1~TS31 Framed Ethernet service occupies the time-slot Unframed Ethernet service does not occupy the time-slot Note: When E1 is framed mode, it needs to ensure the switches of time-slot occupation is not all Off, at least there is one switch is On.
Raisecom Technology Co., Ltd 5. Troubleshooting If you meet troubles in installation and application, please try to solve the problems according to the following suggestions. If they cannot be solved, please contact technical staff to support. Power indicator(PWR) is OFF There is fault in power supply system.
Page 13