JY997D50601B
Side
JAPANESE
A
Side
ENGLISH
B
FX
-1PG-E
2N
INSTALLATION MANUAL
Manual Number
JY997D50601
Revision
B
Date
April 2015
This manual describes the part names, dimensions, mounting, wiring, and
specifications of the product. Before use, read this manual and the manuals of all
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
Store this manual in a safe place so that it can be taken out and read whenever
necessary. Always forward it to the end user.
Registration:
The company and product names described in this manual are registered
trademarks or the trademarks of their respective companies.
Effective April 2015
Specifications are subject to change without notice.
2013 Mitsubishi Electric Corporation
Safety Precaution
(Read these precautions before use.)
This manual classify the safety precautions into two categories:
and
.
Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.
Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.
Depending on circumstances, procedures indicated by
linked to serious results.
In any case, it is important to follow the directions for usage.
Associated Manuals
Manual name
Manual No.
Description
JY992D65301
FX
-1PG/FX-1PG
Describes FX
-1PG/FX-1PG pulse
2N
2N
MODEL CODE:
User's Manual
output block details.
09R610
FX
Series
JY997D16501
E x p l a i n s F X
S e r i e s P L C
3U
3 U
User's Manual
MODEL CODE:
specification details for I/O, wiring,
- Hardware Edition
09R516
installation, and maintenance.
FX
Series
JY997D28701
E x p l a i n s F X
S e r i e s P L C
3UC
3 U C
User's Manual
MODEL CODE:
specification details for I/O, wiring,
- Hardware Edition
09R519
installation, and maintenance.
JY992D66301
E x p l a i n s F X
2 N
S e r i e s P L C
FX
2N
MODEL CODE:
specification details for I/O, wiring,
HARDWARE MANUAL
09R508
installation, and maintenance.
Explains FX
(D/UL) Series PLC
2NC
FX
(D/UL)
2NC
JY992D87201
specification details for I/O, wiring,
HARDWARE MANUAL
installation, and maintenance.
JY992D76401
Explains FX
(DSS/DS) Series
2NC
FX
2NC
(DSS/DS)
MODEL CODE:
PLC specification details for I/O,
HARDWARE MANUAL
09R509
wiring, installation, and maintenance.
FX
3S
/FX
3G
/FX
3GC
/
FX
3U
/FX
3UC
Series
JY997D16601
Describes PLC programming for
Programming Manual
MODEL CODE:
b a s i c / a p p l i e d i n s t ru c t i o n s a n d
- Basic & Applied
09R517
devices.
Instruction Edition
Side
B
How to obtain manuals
For the necessary product manuals or documents, consult with the Mitsubishi Electric
dealer from where you purchase your product.
Certification of UL, cUL standards
FX
-1PG-E units comply with the UL standards (UL, cUL).
2N
UL, cUL File Number: E95239
Regarding the standards that comply with the main unit, please refer to either the FX
series product catalog or consult with your nearest Mitsubishi product provider.
Compliance with EC directive (CE Marking)
This document does not guarantee that a mechanical system including this product will
comply with the following standards.
Compliance to EMC directive and LVD directive for the entire mechanical module
should be checked by the user/manufacturer. For more information please consult with
your nearest Mitsubishi product provider.
Requirement for Compliance with EMC directive
The following products have shown compliance through direct testing (of the identified
standards below) and design analysis (through the creation of a technical construction
file) to the European Directive for Electromagnetic Compatibility (2004/108/EC) when
used as directed by the appropriate documentation.
Attention
This product is designed for use in industrial applications.
Note
Authorized Representative in the European Community:
Mitsubishi Electric Europe B.V.
Gothaer Str. 8, 40880 Ratingen, Germany
Type:
Programmable Controller (Open Type Equipment)
Models:
MELSEC FX
2N
series manufactured
from September 1st, 1997
FX
2N
-1PG-E
Standard
C omp lia nce w ith a ll rele van t aspe cts of th e
*1
EN61131-2:2007
standard.
Programmable controllers
EMI
- Equipment requirements
• Radiated Emission
and tests
• Conducted Emission
EMS
• Radiated electromagnetic field
• Fast transient burst
• Electrostatic discharge
• High-energy surge
• Voltage drops and interruptions
• Conducted RF
may also be
• Power frequency magnetic field
*1 FX
-1PG-E products produced before July 31 2010 comply with EN61131-2:2003.
2N
Caution for EC Directive
Notes for compliance with EN61131-2:2007
General notes on the use of the power supply cable.
The FX
-1PG-E unit require that the cable used for power supply is 30 m or less.
2N
1. Outline
1.1 Outline
The FX
-1PG-E pulse output block performs simple positioning of an independent
2N
axis (not interpolation control between multiple axes) by supplying a prescribed
quantity of pulses (100 kHz maximum) to drive amplifiers for servo or stepper motors.
1.2 Incorporated Items
Check if the following product and items are included in the package:
Included Items
FX
-1PG-E
1 unit
2N
No. labels for special modules
1 sheet
Dust proof protection sheet
1 sheet
Manuals (Japanese/English)
1 manual
1.3 External Dimensions, Part Names
[4]
2-4.5 mounting holes
[3]
[2]
[1]
4 (0.16")
43 (1.7")
[Without top cover]
[8]
[9]
Remark
[8]
[1] Status LEDs (red)
[2] Extension cable
[3] Power LED (green)
[4] Direct mounting hole
2 holes of
4.5 (0.18")
(mounting screw: M4 screw)
[5] Name plate
1.4 Status LED
LED
Display
Indicates power status of FX
POWER
Lighted when 5 V is supplied from PLC.
STOP
Lighted when the stop command is input to the STOP terminal.
DOG
Lighted when DOG input is entered.
PG0
Lighted when zero point signal is entered.
Flashes when forward pulse or pulses
FP
are output.
Flashes when reverse pulse is output.
RP
Lighted when direction is output.
CLR
Lighted when CLR signal is output.
Flashes when error has occurred.
ERR
Start command is not accepted when error has occurred.
Industrial automation
Elincom Group
European Union: www.elinco.eu
Russia: www.elinc.ru
1.5 Terminal Layout
[5]
[6]
[7]
87 (3.43")
Terminal
Name
VIN
Power terminal for pulse output (5 to 24 V DC, 35 mA or less)
COM0
Common terminal for pulse output
Terminal which outputs forward pulse or pulses.
FP
100 kHz, 20 mA or less (5 to 24 V DC)
Unit: mm (inches)
Terminal which outputs reverse pulse or direction.
MASS (Weight): Approx. 0.2 kg (0.44 lbs)
RP
100 kHz, 20 mA or less (5 to 24 V DC)
Enters zero point signal from drive unit or servo amplifier.
PG0-
Response pulse width: 4 s or more
PG0+
Power terminal for zero point signal. (5 to 24 V DC, 20 mA or less)
COM1
Common terminal for CLR output
Output for clearing deviation counter. (5 to 24 V DC, 20 mA or less)
CLR
Output pulse width: 20 ms (Output when return to home position is
completed or LIMIT SWITCH input is given.)
24 V DC power terminal for STOP input and DOG input.
[6] DIN rail mounting groove
S/S
Connected to sensor power supply of PLC or external power supply.
(DIN rail: DIN46277,
35 mm (1.38") width)
DECELERATION STOP input.
STOP
Can function as stop command input in external command
[7] DIN rail mounting hook
operation mode.
[8] Terminal block (M3 screw)
Offers following different functions depending on operation mode.
Machine home position return operation: NEAR POINT SIGNAL
[9] Extension connector
input
DOG
Interrupt single-speed operation: INTERRUPT input
External command operation: DECELERATION START input
1.5.1
Terminal screws and tightening torque
For the terminals of FX
Description
Tighten the screws to a torque of 0.5 to 0.8 N
Do not tighten terminal screws with a torque exceeding the regulation torque.
-1PG-E.
2N
Failure to do so may cause equipment failures or malfunctions.
For details on the wiring needed to connect to the terminal blocks shown in the
figure above, refer to the following manual.
O u t p u t f o r m a t c a n b e
modified using BFM#3 b8.
Description
-1PG-E, M3 screws are used.
2N
m.
Refer to FX
-1PG/FX-1PG User's Manual.
2N