RRU3201
Installation Guide
----End
8.8 Opening the Cover Plate of an RRU Cabling Cavity
This section describes the procedure for opening the cover plate of an RRU cabling cavity.
Procedure
Step 1 Wear ESD gloves.
Take proper ESD protection measures, for example, wear ESD gloves, to prevent electrostatic
damage to the boards, modules, or electronic components.
Step 2 Loosen the six screws on the cover plate of the RRU cabling cavity using an M4 Phillips
screwdriver, and then open the cover plate, as shown in
Issue 06 (2012-04-16)
2.
Connect the other end of the AISG extension cable to the standard AISG male
connector on the RCU, as shown in
Figure 8-13 Installing an RRU AISG extension cable
3.
Lay out the cable by referring to
using cable ties.
4.
Label the installed cable by referring to Attaching an L-Shaped Label.
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Figure
8-13.
8.1 Cabling
Requirements, and then bind the cable
Figure
8-14.
8 Installing RRU Cables
76